← Back

Schneider Electric

schneider-electric

783 CVEs • 1,762 products

Products (1,762)

Click to collapse
Toggle
Proclima
proclima
Clearscada
clearscada

CVEs (783)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
6Canonical
DebianHp+3 more
13Debian Linux
Enterprise Linux DesktopEnterprise Linux Server+10 more
May 6, 2025
Apr 19, 2018
N/A· v4
3.1 LOW· v3
2.6 LOW· v2
Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: Security). Supported versions that are affected are Java SE: 6u181, 7u171, 8u162 and 10; Java SE Embedded: 8u161. Difficult to exp...Show more
Vulnerability in the Java SE, Java SE Embedded component of Oracle Java SE (subcomponent: Security). Supported versions that are affected are Java SE: 6u181, 7u171, 8u162 and 10; Java SE Embedded: 8u161. Difficult to exploit vulnerability allows unauthenticated attacker with network access via multiple protocols to compromise Java SE, Java SE Embedded. Successful attacks require human interaction from a person other than the attacker. Successful attacks of this vulnerability can result in unauthorized update, insert or delete access to some of Java SE, Java SE Embedded accessible data. Note: This vulnerability applies to Java deployments, typically in clients running sandboxed Java Web Start applications or sandboxed Java applets, that load and run untrusted code (e.g., code that comes from the internet) and rely on the Java sandbox for security. This vulnerability does not apply to Java deployments, typically in servers, that load and run only trusted code (e.g., code installed by an administrator). CVSS 3.0 Base Score 3.1 (Integrity impacts). CVSS Vector: (CVSS:3.0/AV:N/AC:H/PR:N/UI:R/S:U/C:N/I:L/A:N).Show less
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (ins...Show more
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.Show less
1Schneider Electric
23Micom P141 Firmware
Micom P142 FirmwareMicom P143 Firmware+20 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
6.5 MEDIUM· v3
3.3 LOW· v2
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network co...Show more
A denial of service vulnerability exists in Schneider Electric's MiCOM Px4x (P540 range excluded) with legacy Ethernet board, MiCOM P540D Range with Legacy Ethernet Board, and MiCOM Px4x Rejuvenated could lose network communication in case of TCP/IP open requests on port 20000 (DNP3oE) if an older TCI/IP session is still open with identical IP address and port number.Show less
1Schneider Electric
166074 Mge Network Management Card Transverse
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of...Show more
A cleartext transmission of sensitive information vulnerability exists in Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. he integrated web server (Port 80/443/TCP) of the affected devices could allow remote attackers to discover an administrative account. If default on device, it is not using a SSL in settings and if multiple request of the page "Access Control" (IP-address device/ups/pas_cont.htm) account data will be sent in cleartextShow less
1Schneider Electric
166074 Mge Network Management Card Transverse
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.1 CRITICAL· v3
6.4 MEDIUM· v2
An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices co...Show more
An improper authorization vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to change UPS control and shutdown parameters or other critical settings without authorization.Show less
1Schneider Electric
166074 Mge Network Management Card Transverse
Jun 17, 2026
Apr 18, 2018
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices co...Show more
An information disclosure vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to obtain sensitive device information if network access was obtained.Show less
1Schneider Electric
166074 Mge Network Management Card Transverse
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices coul...Show more
An authorization bypass vulnerability exists In Schneider Electric's 66074 MGE Network Management Card Transverse installed in MGE UPS and MGE STS. The integrated web server (Port 80/443/TCP) of the affected devices could allow a remote attacker to get a full access to device, bypassing the authorization system.Show less
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the passwor...Show more
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.Show less
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
1Schneider Electric
13140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+10 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
8.8 HIGH· v3
6.5 MEDIUM· v2
A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be mis...Show more
A vulnerability exists in Schneider Electric's Modicon Quantum in all versions of the communication modules which could allow arbitrary code execution. An FTP command used to upgrade the firmware of the module can be misused to cause a denial of service, or in extreme cases, to load a malicious firmware.Show less
1Schneider Electric
13Atv12 Dtm
Atv212 DtmAtv312 Dtm+10 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A DLL hijacking vulnerability exists in Schneider Electric's SoMove Software and associated DTM software components in all versions prior to 2.6.2 which could allow an attacker to execute arbitrary code.
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbit...Show more
A buffer overflow vulnerability exist in the web-based GUI of Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow an unauthenticated, remote attacker to execute arbitrary code.Show less
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
9.1 CRITICAL· v3
6.4 MEDIUM· v2
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /logi...Show more
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow a remote attacker to delete arbitrary system file due to lack of validation of the /login/bin/set_param to the file name with the value of 'system.delete.sd_file'Show less
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
8.1 HIGH· v3
5.8 MEDIUM· v2
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH ser...Show more
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could enable SSH service due to lack of authentication for /login/bin/set_param could enable SSH service.Show less
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters wi...Show more
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of the shell meta characters with the value of 'system.download.sd_file'Show less
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow arbitrary system file download due to lack of validation of SSL certificate.
1Schneider Electric
20Ibp1110 1er Firmware
Ibp219 1er FirmwareIbp319 1er Firmware+17 more
Jun 17, 2026
Mar 9, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability exists in Schneider Electric's Pelco Sarix Professional in all firmware versions prior to 3.29.67 which could allow execution of commands due to lack of validation of the shell meta characters with the va...Show more