CVEs (10)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 6.5 MEDIUM· v3 4.0 MEDIUM· v2 Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause information to be exposed when an unauthorized file is uploaded. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 Information Exposure vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a device to be compromised when it is first configured. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 9.8 CRITICAL· v3 5.0 MEDIUM· v2 Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access when credentials are discovered after a brute force att...Show more |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 9.8 CRITICAL· v3 5.0 MEDIUM· v2 Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of when credentials are discovered after a brute force attack. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a denial of service when an unauthorized fil...Show more |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 7.2 HIGH· v3 6.5 MEDIUM· v2 Improper Verification of Cryptographic Signature vulnerability exists inhomeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could allow remote code execution when unauthorized code is copied to the device. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 7.2 HIGH· v3 6.5 MEDIUM· v2 Improper Verification of Cryptographic Signature vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause remote code execution when an attacker loads unauthorized code. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 7.8 HIGH· v3 4.6 MEDIUM· v2 Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause shell access when unauthorized code is loaded into the system folder. |
1Schneider Electric 2Homelynk Firmware Spacelynk FirmwareJun 17, 2026 May 26, 2021 N/A· v4 7.8 HIGH· v3 4.6 MEDIUM· v2 Improper Privilege Management vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior which could cause a code execution issue when an attacker loads unauthorized code on the web server. |
1Schneider Electric 3Homelynk Firmware Spacelynk FirmwareWiser For Knx FirmwareJun 17, 2026 Jul 3, 2018 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 In Schneider Electric Wiser for KNX V2.1.0 and prior, homeLYnk V2.0.1 and prior; and spaceLYnk V2.1.0 and prior, weak and unprotected FTP access could allow an attacker unauthorized access. |