Ecostruxure Geo Scada Expert 2020
ecostruxure_geo_scada_expert_2020
Vendor: Schneider Electric • 9 CVEs
CVEs (9)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Schneider Electric 4Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020+1 moreJun 17, 2026 Feb 24, 2023 N/A· v4 5.3 MEDIUM· v3 N/A· v2 A CWE-117: Improper Output Neutralization for Logs vulnerability exists that could cause the misinterpretation of log files when malicious packets are sent to the Geo SCADA server's database web port (default 443). Affec...Show more |
1Schneider Electric 3Ecostruxure Geo Scada Expert 2019 Ecostruxure Geo Scada Expert 2020Ecostruxure Geo Scada Expert 2021Jun 17, 2026 Jan 31, 2023 N/A· v4 7.5 HIGH· v3 N/A· v2 A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected...Show more |
1Schneider Electric 3Ecostruxure Geo Scada Expert 2019 Ecostruxure Geo Scada Expert 2020Ecostruxure Geo Scada Expert 2021Jun 17, 2026 Jan 31, 2023 N/A· v4 7.5 HIGH· v3 N/A· v2
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of
Service against the Geo SCADA server when specific messages are sent to the server over the
database server TCP port.
|
1Schneider Electric 3Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020Jun 17, 2026 Feb 9, 2022 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause Denial of Service against the Geo SCADA server when receiving a malformed HTTP request. Affected Product: ClearSCADA (...Show more |
1Schneider Electric 3Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020Jun 17, 2026 Feb 9, 2022 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA database server are intercepted. Affected Product: ClearSCAD...Show more |
1Schneider Electric 3Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020Jun 17, 2026 Feb 9, 2022 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 A CWE-295: Improper Certificate Validation vulnerability exists that could allow a Man-in-theMiddle attack when communications between the client and Geo SCADA web server are intercepted. Affected Product: ClearSCADA (Al...Show more |
1Schneider Electric 3Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020Jun 17, 2026 Feb 9, 2022 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 A CWE-326: Inadequate Encryption Strength vulnerability exists that could cause non-encrypted communication with the server when outdated versions of the ViewX client are used. Affected Product: ClearSCADA (All Versions)...Show more |
1Schneider Electric 3Clearscada Ecostruxure Geo Scada Expert 2019Ecostruxure Geo Scada Expert 2020Jun 17, 2026 May 26, 2021 N/A· v4 6.7 MEDIUM· v3 4.6 MEDIUM· v2 Use of Password Hash with Insufficient Computational Effort vulnerability exists in ClearSCADA (all versions), EcoStruxure Geo SCADA Expert 2019 (all versions), and EcoStruxure Geo SCADA Expert 2020 (V83.7742.1 and prior...Show more |
1Schneider Electric 2Ecostruxure Geo Scada Expert 2019 Ecostruxure Geo Scada Expert 2020Jun 17, 2026 Dec 11, 2020 N/A· v4 7.8 HIGH· v3 2.1 LOW· v2 A CWE-522: Insufficiently Protected Credentials vulnerability exists in EcoStruxure Geo SCADA Expert 2019 (Original release and Monthly Updates to September 2020, from 81.7268.1 to 81.7578.1) and EcoStruxure Geo SCADA Ex...Show more |