← Back

Schneider Electric

schneider-electric

771 CVEs • 1,745 products

Products (1,745)

Click to collapse
Toggle
Proclima
proclima
Clearscada
clearscada

CVEs (771)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
May 29, 2026
Jun 11, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
May 29, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially cr...Show more
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packetShow less
1Schneider Electric
4Powerlogic Pm5560 Firmware
Powerlogic Pm5561 FirmwarePowerlogic Pm5562 Firmware+1 more
May 29, 2026
Jun 11, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connec...Show more
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.Show less
1Schneider Electric
5Powerlogic Pm5560 Firmware
Powerlogic Pm5561 FirmwarePowerlogic Pm5562 Firmware+2 more
May 29, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation)...Show more
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file...Show more
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+...Show more
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplie...Show more
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file...Show more
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input...Show more
A CWE-824: Access of uninitialized pointer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack validation of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied...Show more
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied input data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation,...Show more
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of user-supplied data validation, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplie...Show more
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code execution due to lack of sanity checks on user-supplied data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, w...Show more
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to lack of proper validation of user-supplied data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is...Show more
A CWE-125: Out-of-bounds read vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious WSP file is being parsed by IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspa...Show more
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing size checks, when a malicious WSP (Workspace) file is being parsed by IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when...Show more
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or execution of arbitrary code due to lack of input validation, when a malicious CGF (Configuration Group File) file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Nov 21, 2024
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file i...Show more
A CWE-787: Out-of-bounds write vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21041 and prior that could result in loss of data or remote code execution due to missing length checks, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Modicon X80 Bmxnor0200h Rtu Firmware
Nov 21, 2024
Jun 11, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration i...Show more
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists in Modicon X80 BMXNOR0200H RTU SV1.70 IR22 and prior that could cause information leak concerning the current RTU configuration including communication parameters dedicated to telemetry, when a specially crafted HTTP request is sent to the web server of the module.Show less
1Schneider Electric
2Tcm 4351b Firmware
Triconex Model 3009 Mp Firmware
Nov 21, 2024
May 26, 2021
N/A· v4
3.9 LOW· v3
2.1 LOW· v2
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while t...Show more
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.Show less
1Schneider Electric
2Tcm 4351b Firmware
Triconex Model 3009 Mp Firmware
Nov 21, 2024
May 26, 2021
N/A· v4
3.9 LOW· v3
2.1 LOW· v2
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while t...Show more
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747.Show less