← Back

Schneider Electric

schneider-electric

783 CVEs • 1,762 products

Products (1,762)

Click to collapse
Toggle
Proclima
proclima
Clearscada
clearscada

CVEs (783)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
6Evlink City Evc1s22p4 Firmware
Evlink City Evc1s7p4 FirmwareEvlink Parking Ev.2 Firmware+3 more
Jun 17, 2026
Jul 21, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbo...Show more
A CWE-200: Information Exposure vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to get limited knowledge of javascript code when crafted malicious parameters are submitted to the charging station web server.Show less
1Schneider Electric
6Evlink City Evc1s22p4 Firmware
Evlink City Evc1s7p4 FirmwareEvlink Parking Ev.2 Firmware+3 more
Jun 17, 2026
Jul 21, 2021
N/A· v4
7.2 HIGH· v3
6.5 MEDIUM· v2
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0...Show more
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to craft a malicious firmware package and bypass the signature verification mechanism.Show less
1Schneider Electric
6Evlink City Evc1s22p4 Firmware
Evlink City Evc1s7p4 FirmwareEvlink Parking Ev.2 Firmware+3 more
Jun 17, 2026
Jul 21, 2021
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Sma...Show more
A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to issue unauthorized commands to the charging station web server with administrative privileges.Show less
1Schneider Electric
6Evlink City Evc1s22p4 Firmware
Evlink City Evc1s7p4 FirmwareEvlink Parking Ev.2 Firmware+3 more
Jun 17, 2026
Jul 21, 2021
N/A· v4
6.1 MEDIUM· v3
4.3 MEDIUM· v2
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / E...Show more
A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.2 all versions prior to R8 V3.4.0.1), and EVlink Smart Wallbox (EVB1A all versions prior to R8 V3.4.0.1 ) that could allow an attacker to impersonate the user who manages the charging station or carry out actions on their behalf when crafted malicious parameters are submitted to the charging station web server.Show less
1Schneider Electric
3Ecostruxure Control Expert
Ecostruxure Process ExpertRemoteconnect
Jun 17, 2026
Jul 14, 2021
N/A· v4
5.5 MEDIUM· v3
2.1 LOW· v2
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more
Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file.Show less
1Schneider Electric
3Ecostruxure Control Expert
Ecostruxure Process ExpertRemoteconnect
Jun 17, 2026
Jul 14, 2021
N/A· v4
5.5 MEDIUM· v3
2.1 LOW· v2
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file.Show less
1Schneider Electric
3Ecostruxure Control Expert
Ecostruxure Process ExpertRemoteconnect
Jun 17, 2026
Jul 14, 2021
N/A· v4
7.1 HIGH· v3
3.6 LOW· v2
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to view and modify a project file.Show less
1Schneider Electric
32Ecostruxure Control Expert
Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+29 more
Jun 17, 2026
Jul 14, 2021
N/A· v4
9.1 CRITICAL· v3
6.4 MEDIUM· v2
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Exper...Show more
Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in read and write mode to the controller by spoofing the Modbus communication between the engineering software and the controller.Show less
1Schneider Electric
3Ecostruxure Control Expert
Ecostruxure Process ExpertRemoteconnect
Jun 17, 2026
Jul 14, 2021
N/A· v4
7.1 HIGH· v3
3.6 LOW· v2
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more
Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file.Show less
1Schneider Electric
1Easergy T300 Firmware
Jun 29, 2026
Jun 11, 2021
N/A· v4
4.3 MEDIUM· v3
4.0 MEDIUM· v2
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restrict...Show more
A CWE-552: Files or Directories Accessible to External Parties vulnerability exists in Easergy T300 with firmware V2.7.1 and older that could expose files or directory content when access from an attacker is not restricted or incorrectly restricted.Show less
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
Jun 17, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially cr...Show more
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-22767Show less
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
Jun 17, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially cr...Show more
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packet.This CVE ID is unique from CVE-2021-2276Show less
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
Jun 17, 2026
Jun 11, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service via a specially crafted HTTP packet
1Schneider Electric
2Powerlogic Egx100 Firmware
Powerlogic Egx300 Firmware
Jun 17, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially cr...Show more
A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause denial of service or remote code execution via a specially crafted HTTP packetShow less
1Schneider Electric
4Powerlogic Pm5560 Firmware
Powerlogic Pm5561 FirmwarePowerlogic Pm5562 Firmware+1 more
Jun 17, 2026
Jun 11, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connec...Show more
A CWE-287: Improper Authentication vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could cause loss of connectivity to the device via Modbus TCP protocol when an attacker sends a specially crafted HTTP request.Show less
1Schneider Electric
5Powerlogic Pm5560 Firmware
Powerlogic Pm5561 FirmwarePowerlogic Pm5562 Firmware+2 more
Jun 17, 2026
Jun 11, 2021
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation)...Show more
A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLogic EGX300 (see security notification for version infromation) that could allow an attacker administrator level access to a device.Show less
1Schneider Electric
1Interactive Graphical Scada System
Jun 17, 2026
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file...Show more
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in remote code execution, when a malicious CGF or WSP file is being parsed by IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Jun 17, 2026
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+...Show more
A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in disclosure of information or remote code e+F15xecution due to missing length check on user supplied data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Jun 17, 2026
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplie...Show more
A CWE-763: Release of invalid pointer or reference vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to missing checks of user-supplied input data, when a malicious CGF file is imported to IGSS Definition.Show less
1Schneider Electric
1Interactive Graphical Scada System
Jun 17, 2026
Jun 11, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file...Show more
A CWE-416: Use after free vulnerability exists inIGSS Definition (Def.exe) V15.0.0.21140 and prior that could result in loss of data or remote code execution due to use of unchecked input data, when a malicious CGF file is imported to IGSS Definition.Show less