← Back

Schneider Electric

schneider-electric

783 CVEs • 1,762 products

Products (1,762)

Click to collapse
Toggle
Proclima
proclima
Clearscada
clearscada

CVEs (783)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
1Powerlogic P7 Firmware
Jul 1, 2026
Jun 25, 2026
6.9 MEDIUM· v4
6.5 MEDIUM· v3
N/A· v2
CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable...Show more
CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availability when a specially crafted request is sent to a vulnerable network-exposed service.Show less
1Schneider Electric
1Powerlogic P7 Firmware
Jul 1, 2026
Jun 25, 2026
8.6 HIGH· v4
7.2 HIGH· v3
N/A· v2
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, conf...Show more
CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of commands with elevated privileges, impacting system integrity, confidentiality, and availability when a privileged authenticated user interacts with a vulnerable network-exposed service.Show less
1Schneider Electric
1Powerlogic P7 Firmware
Jul 1, 2026
Jun 25, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over expos...Show more
CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionality unavailable when malformed requests are received over exposed network interfaces.Show less
1Schneider Electric
2Easylogic T150 Firmware
Saitel Dp Firmware
Jul 14, 2026
Jun 25, 2026
6.7 MEDIUM· v4
4.4 MEDIUM· v3
N/A· v2
CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads...Show more
CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads improperly protected system files.Show less
1Schneider Electric
2Easylogic T150 Firmware
Saitel Dp Firmware
Jul 14, 2026
Jun 25, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system fi...Show more
CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system files. With this credential an attacker could subsequently compromise the device if they have physical access to the device.Show less
1Schneider Electric
1Struxureware Data Center Expert
Jul 20, 2026
Jun 9, 2026
7.1 HIGH· v4
6.5 MEDIUM· v3
N/A· v2
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits craf...Show more
CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an attacker with a Data Center Expert user account submits crafted XML payloads to SOAP service endpoints.Show less
1Schneider Electric
1Ecostruxure Machine Expert Hvac
Jun 17, 2026
May 14, 2026
6.8 MEDIUM· v4
7.5 HIGH· v3
N/A· v2
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revealing protected source code and loss of confidentiality, When...Show more
CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revealing protected source code and loss of confidentiality, When an authorized attacker accesses the source code for editing or compiling it.Show less
1Schneider Electric
5Ecostruxure Panel Server Pas400 Firmware
Ecostruxure Panel Server Pas600 FirmwareEcostruxure Panel Server Pas600v2 Firmware+2 more
Jun 24, 2026
May 12, 2026
8.2 HIGH· v4
7.5 HIGH· v3
N/A· v2
CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, ena...Show more
CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials.Show less
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
6.5 MEDIUM· v3
N/A· v2
CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
4.3 MEDIUM· v3
N/A· v2
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with dif...Show more
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.Show less
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
2.4 LOW· v4
5.0 MEDIUM· v3
N/A· v2
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
4.3 MEDIUM· v3
N/A· v2
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
6.1 MEDIUM· v3
N/A· v2
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep r...Show more
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.Show less
1Schneider Electric
1Ecostruxure Automation Expert
Jun 23, 2026
Mar 10, 2026
7.2 HIGH· v4
8.2 HIGH· v3
N/A· v2
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the work...Show more
CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering workstation which could result in a limited compromise of the workstation and a potential loss of Confidentiality, Integrity and Availability of the subsequent system when an authenticated user opens a malicious project file.Show less
1Schneider Electric
1Ecostruxure Foxboro Dcs Control Software
Jun 24, 2026
Mar 10, 2026
7.0 HIGH· v4
6.5 MEDIUM· v3
N/A· v2
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious...Show more
CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on workstation when an admin authenticated user opens a malicious project file.Show less
1Schneider Electric
4Modicon Lmc058 Firmware
Modicon M241 FirmwareModicon M251 Firmware+1 more
Jun 23, 2026
Mar 10, 2026
5.1 MEDIUM· v4
5.4 MEDIUM· v3
N/A· v2
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScri...Show more
CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated attackers can have a victim’s browser run arbitrary JavaScript when the victim hovers over a maliciously crafted element on a web server containing the injected payload.Show less
1Schneider Electric
3Modicon M241 Firmware
Modicon M251 FirmwareModicon M262 Firmware
Jun 23, 2026
Mar 10, 2026
6.9 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communica...Show more
CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticated attacker sends malicious payload to occupy active communication channels.Show less
1Schneider Electric
2Ecostruxure Power Monitoring Expert
Ecostruxure Power Operation
Jun 24, 2026
Mar 10, 2026
8.5 HIGH· v4
7.8 HIGH· v3
N/A· v2
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsaf...Show more
CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authenticated attacker sends a crafted data stream, triggering unsafe deserialization.Show less