CVEs (11)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Philips 1Patient Information Center Ix Jun 17, 2026 Dec 27, 2021 N/A· v4 5.5 MEDIUM· v3 2.1 LOW· v2 The use of a hard-coded cryptographic key significantly increases the possibility encrypted data may be recovered from the Patient Information Center iX (PIC iX) Versions B.02, C.02, and C.03. |
1Philips 2Efficia Cm Firmware Patient Information Center IxJun 17, 2026 Dec 27, 2021 N/A· v4 6.5 MEDIUM· v3 3.3 LOW· v2 The use of a broken or risky cryptographic algorithm is an unnecessary risk that may result in the exposure of sensitive information, which affects the communications between Patient Information Center iX (PIC iX) Versio...Show more |
1Philips 1Patient Information Center Ix Jun 17, 2026 Dec 27, 2021 N/A· v4 6.5 MEDIUM· v3 3.3 LOW· v2 Patient Information Center iX (PIC iX) Versions C.02 and C.03 receives input or data, but does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly. |
1Philips 1Patient Information Center Ix Jun 17, 2026 Sep 11, 2020 N/A· v4 6.5 MEDIUM· v3 3.3 LOW· v2 In Patient Information Center iX (PICiX) Versions C.02, C.03, the software parses a formatted message or structure but does not handle or incorrectly handles a length field that is inconsistent with the actual length...Show more |
1Philips 2Patient Information Center Ix Performancebridge Focal PointJun 17, 2026 Sep 11, 2020 N/A· v4 4.3 MEDIUM· v3 3.3 LOW· v2 In Patient Information Center iX (PICiX) Versions C.02, C.03, PerformanceBridge Focal Point Version A.01, the product receives input that is expected to be well-formed (i.e., to comply with a certain syntax) but it do...Show more |
1Philips 13Intellivue Mp2 Mp90 Firmware Intellivue Mx100 FirmwareIntellivue Mx400 Firmware+10 moreJun 17, 2026 Sep 11, 2020 N/A· v4 6.5 MEDIUM· v3 6.1 MEDIUM· v2 In IntelliVue patient monitors MX100, MX400-550, MX600, MX700, MX750, MX800, MX850, MP2-MP90, and IntelliVue X2 and X3 Versions N and prior, the product receives input or data but does not validate or incorrectly vali...Show more |
1Philips 1Patient Information Center Ix Jun 17, 2026 Sep 11, 2020 N/A· v4 6.8 MEDIUM· v3 4.6 MEDIUM· v2 In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the product exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource. The application on th...Show more |
1Philips 13Intellivue Mp2 Mp90 Firmware Intellivue Mx100 FirmwareIntellivue Mx400 Firmware+10 moreJun 17, 2026 Sep 11, 2020 N/A· v4 6.4 MEDIUM· v3 5.2 MEDIUM· v2 In Patient Information Center iX (PICiX) Versions C.02 and C.03, PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and prior, the so...Show more |
1Philips 2Patient Information Center Ix Performancebridge Focal PointJun 17, 2026 Sep 11, 2020 N/A· v4 8.8 HIGH· v3 5.8 MEDIUM· v2 In Patient Information Center iX (PICiX) Version B.02, C.02, C.03, and PerformanceBridge Focal Point Version A.01, when an actor claims to have a given identity, the software does not prove or insufficiently proves th...Show more |
1Philips 1Patient Information Center Ix Jun 17, 2026 Sep 11, 2020 N/A· v4 3.5 LOW· v3 2.7 LOW· v2 In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is then used as a webpage and...Show more |
1Philips 1Patient Information Center Ix Jun 17, 2026 Sep 11, 2020 N/A· v4 5.0 MEDIUM· v3 5.8 MEDIUM· v2 In Patient Information Center iX (PICiX) Versions B.02, C.02, C.03, the software saves user-provided information into a comma-separated value (CSV) file, but it does not neutralize or incorrectly neutralizes special e...Show more |