CVE-2020-16228
6.4
Vector
CVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:L
Exploitability: 0.9 / Impact: 5.5
Source: NVD
Description
In Patient Information Center iX (PICiX) Versions C.02 and C.03,
PerformanceBridge Focal Point Version A.01, IntelliVue patient monitors
MX100, MX400-MX550, MX750, MX850, and IntelliVue X3 Versions N and
prior, the software does not check or incorrectly checks the revocation
status of a certificate, which may cause it to use a compromised
certificate.
Affected (15)
Products: Philips: Patient Information Center Ix, Performancebridge Focal Point, Intellivue Mp2 Mp90 Firmware, Intellivue Mx100 Firmware, Intellivue Mx400 Firmware, Intellivue Mx850 Firmware, Intellivue X2 Firmware, Intellivue X3 Firmware, Intellivue Mx800 Firmware, Intellivue Mx750 Firmware, Intellivue Mx700 Firmware, Intellivue Mx600 Firmware, Intellivue Mx550 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version b.02 | |
| Version a.01 |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mp2 Mp90 | Version n |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx100 | All versions |
Configuration D
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx400 | All versions |
Configuration E
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx850 | All versions |
Configuration F
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue X2 | Version n |
Configuration G
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue X3 | Version n |
Configuration H
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx800 | All versions |
Configuration I
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx750 | All versions |
Configuration J
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx700 | All versions |
Configuration K
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx600 | All versions |
Configuration L
| Vulnerable Software | Affected Versions |
|---|---|
| All versions |
| Running on/with | Platform Versions |
|---|---|
Philips Intellivue Mx550 | All versions |
References (4)
Source: ics-cert@hq.dhs.gov
Third Party AdvisoryUS Government Resource
Source: ics-cert@hq.dhs.gov
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Timeline
No history available yet.