CVE-2017-6030
6.5
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L
Exploitability: 3.9 / Impact: 2.5
Source: NVD
Description
A Predictable Value Range from Previous Values issue was discovered in Schneider Electric Modicon PLCs Modicon M221, firmware versions prior to Version 1.5.0.0, Modicon M241, firmware versions prior to Version 4.0.5.11, and Modicon M251, firmware versions prior to Version 4.0.5.11. The affected products generate insufficiently random TCP initial sequence numbers that may allow an attacker to predict the numbers from previous values. This may allow an attacker to spoof or disrupt TCP connections.
Affected (3)
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Up to 4.0.3.20 |
| Running on/with | Platform Versions |
|---|---|
Schneider Electric Modicon M241 | All versions |
Configuration B
| Vulnerable Software | Affected Versions |
|---|---|
| Up to 4.0.3.20 |
| Running on/with | Platform Versions |
|---|---|
Schneider Electric Modicon M251 | All versions |
Configuration C
| Vulnerable Software | Affected Versions |
|---|---|
| Up to 1.1.1.5 |
| Running on/with | Platform Versions |
|---|---|
Schneider Electric Modicon M221 | All versions |
Related CWEs
CWE-331
Insufficient Entropy
The product uses an algorithm or scheme that produces insufficient entropy, leaving patterns or clusters of values that are more likely to occur than others.
CWE-343
Predictable Value Range from Previous Values
The product's random number generator produces a series of values which, when observed, can be used to infer a relatively small range of possibilities for the next value that could be generated.
References (4)
Source: ics-cert@hq.dhs.gov
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryVDB Entry
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Timeline
No history available yet.