← Back

Tenda

tenda

1,840 CVEs • 218 products

Products (218)

Click to collapse
Toggle
Ac6 Firmware
ac6_firmware
Ac9 Firmware
ac9_firmware
Ac10 Firmware
ac10_firmware
Ac15 Firmware
ac15_firmware
Ac7 Firmware
ac7_firmware
W30e Firmware
w30e_firmware
Ac8 Firmware
ac8_firmware
Ax3 Firmware
ax3_firmware
M3 Firmware
m3_firmware
Ac5 Firmware
ac5_firmware
Ch22 Firmware
ch22_firmware
W15e Firmware
w15e_firmware
Ax12 Firmware
ax12_firmware
F453 Firmware
f453_firmware
Ac21 Firmware
ac21_firmware
Ac23 Firmware
ac23_firmware
G3 Firmware
g3_firmware
W20e Firmware
w20e_firmware
A15 Firmware
a15_firmware
F456 Firmware
f456_firmware
Ac20 Firmware
ac20_firmware
I21 Firmware
i21_firmware
W9 Firmware
w9_firmware
I22 Firmware
i22_firmware
Rx3 Firmware
rx3_firmware
O3 Firmware
o3_firmware
F451 Firmware
f451_firmware
W18e Firmware
w18e_firmware
Tx3 Firmware
tx3_firmware
I9 Firmware
i9_firmware
A18 Firmware
a18_firmware
Ax9 Firmware
ax9_firmware
F3 Firmware
f3_firmware
W6 S Firmware
w6-s_firmware
I29 Firmware
i29_firmware
Ac11 Firmware
ac11_firmware
I12 Firmware
i12_firmware
W6 Firmware
w6_firmware
W12 Firmware
w12_firmware
I3 Firmware
i3_firmware
Hg9 Firmware
hg9_firmware
Cp3 Firmware
cp3_firmware
I6 Firmware
i6_firmware
W3 Firmware
w3_firmware
I24 Firmware
i24_firmware
A21 Firmware
a21_firmware
G1 Firmware
g1_firmware
G103 Firmware
g103_firmware
Tx9 Firmware
tx9_firmware
O6 Firmware
o6_firmware
Hg10 Firmware
hg10_firmware
Hg3 Firmware
hg3_firmware
N301 Firmware
n301_firmware
N300 Firmware
n300_firmware
O1 Firmware
o1_firmware
A5s Firmware
a5s_firmware
A5s
a5s
A32 Firmware
a32_firmware
A32
a32
Hg6 Firmware
hg6_firmware
11n Firmware
11n_firmware
Ac23
ac23
Cp7 Firmware
cp7_firmware
Ac19 Firmware
ac19_firmware
A301 Firmware
a301_firmware
O5 Firmware
o5_firmware

CVEs (1,840)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Tenda
1Ax1806 Firmware
Mar 17, 2025
May 20, 2024
N/A· v4
5.2 MEDIUM· v3
N/A· v2
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.port parameter in the function formSetIptv.
1Tenda
1Ax1806 Firmware
Mar 17, 2025
May 20, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AX1806 v1.0.0.1 contains a stack overflow via the iptv.stb.mode parameter in the function formSetIptv.
1Tenda
1Ac18 Firmware
Mar 17, 2025
May 14, 2024
N/A· v4
8.2 HIGH· v3
N/A· v2
Tenda AC18 v15.03.05.19 is vulnerable to Buffer Overflow in the formSetPPTPServer function via the endIp parameter.
1Tenda
1Fh1206 Firmware
Apr 4, 2025
May 14, 2024
N/A· v4
6.5 MEDIUM· v3
N/A· v2
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/DhcpListClient.
1Tenda
1Fh1206 Firmware
Apr 4, 2025
May 14, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the PPW parameter at ip/goform/WizardHandle.
1Tenda
1Fh1206 Firmware
Apr 4, 2025
May 14, 2024
N/A· v4
8.8 HIGH· v3
N/A· v2
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the list1 parameter at ip/goform/DhcpListClient.
1Tenda
1Fh1206 Firmware
Apr 4, 2025
May 14, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the page parameter at ip/goform/NatStaticSetting.
1Tenda
1Fh1206 Firmware
Apr 4, 2025
May 14, 2024
N/A· v4
8.8 HIGH· v3
N/A· v2
Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter at ip/goform/exeCommand.
1Tenda
1O3 Firmware
Jun 30, 2025
May 14, 2024
N/A· v4
7.2 HIGH· v3
N/A· v2
Tenda O3V2 with firmware versions V1.0.0.10 and V1.0.0.12 was discovered to contain a Blind Command Injection via dest parameter in /goform/getTraceroute. This vulnerability allows attackers to execute arbitrary commands...Show more
Tenda O3V2 with firmware versions V1.0.0.10 and V1.0.0.12 was discovered to contain a Blind Command Injection via dest parameter in /goform/getTraceroute. This vulnerability allows attackers to execute arbitrary commands with root privileges. Authentication is required to exploit this vulnerability.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overf...Show more
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been declared as critical. This vulnerability affects the function formexeCommand. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-263086 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow....Show more
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been classified as critical. This affects the function formWifiMacFilterSet. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263085 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow....Show more
A vulnerability was found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this issue is the function formWifiMacFilterGet. The manipulation of the argument index leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263084. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument...Show more
A vulnerability has been found in Tenda i21 1.0.0.14(4656) and classified as critical. Affected by this vulnerability is the function formSetUplinkInfo of the file /goform/setUplinkInfo. The manipulation of the argument pingHostIp2 leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-263083. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is...Show more
A vulnerability, which was classified as critical, was found in Tenda i21 1.0.0.14(4656). Affected is the function formSetAutoPing. The manipulation of the argument ping1/ping2 leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. VDB-263082 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidInd...Show more
A vulnerability, which was classified as critical, has been found in Tenda i21 1.0.0.14(4656). This issue affects the function formOfflineSet of the file /goform/setStaOffline. The manipulation of the argument GO/ssidIndex leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-263081 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
May 5, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. T...Show more
A vulnerability classified as critical was found in Tenda i21 1.0.0.14(4656). This vulnerability affects the function formGetDiagnoseInfo. The manipulation of the argument cmdinput leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-263080. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1Ac18 Firmware
Apr 10, 2025
May 1, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the remoteIp parameter from formSetSafeWanWebMan function.
1Tenda
1A301 Firmware
May 28, 2025
Apr 27, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument devi...Show more
A vulnerability was found in Tenda A301 15.13.08.12_multi_TDE01. It has been rated as critical. This issue affects the function formAddMacfilterRule of the file /goform/setBlackRule. The manipulation of the argument deviceList leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The associated identifier of this vulnerability is VDB-262223. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I22 Firmware
Jan 27, 2025
Apr 27, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is po...Show more
A vulnerability classified as critical has been found in Tenda i22 1.0.0.3(4687). This affects the function formSetUrlFilterRule. The manipulation of the argument groupIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-262143. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1I21 Firmware
Jan 27, 2025
Apr 27, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcp...Show more
A vulnerability was found in Tenda i21 1.0.0.14(4656). It has been rated as critical. Affected by this issue is the function fromDhcpSetSer of the file /goform/DhcpSetSe. The manipulation of the argument dhcpStartIp/dhcpEndIp/dhcpGw/dhcpMask/dhcpLeaseTime/dhcpDns1/dhcpDns2 leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. VDB-262142 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less