1Tenda
1Ac7 Firmware
Mar 30, 2026
Mar 27, 2026
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time...Show more
A flaw has been found in Tenda AC7 15.03.06.44. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg of the component POST Request Handler. Executing a manipulation of the argument Time can lead to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been published and may be used.Show less
1Tenda
1Ac7 Firmware
Feb 10, 2026
Feb 3, 2026
8.2 HIGH· v4
5.9 MEDIUM· v3
N/A· v2
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose account credentials in plaintext within HTTP responses, allowing an on-path attacker to obtain sensitive authentication material.
1Tenda
1Ac7 Firmware
Feb 10, 2026
Feb 3, 2026
5.1 MEDIUM· v4
6.5 MEDIUM· v3
N/A· v2
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust or...Show more
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior does not implement CSRF protections for administrative functions in the web management interface. The interface does not enforce anti-CSRF tokens or robust origin validation, which can allow an attacker to induce a logged-in administrator to perform unintended state-changing requests and modify router settings.Show less
1Tenda
1Ac7 Firmware
Feb 10, 2026
Feb 3, 2026
6.8 MEDIUM· v4
5.5 MEDIUM· v3
N/A· v2
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaint...Show more
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior expose sensitive information in web management responses. Administrative credentials, including the router and/or admin panel password, are included in plaintext within configuration response bodies. In addition, responses lack appropriate Cache-Control directives, which may permit web browsers to cache pages containing these credentials and enable subsequent disclosure to an attacker with access to the client system or browser profile.Show less
1Tenda
1Ac7 Firmware
Feb 10, 2026
Feb 3, 2026
5.1 MEDIUM· v4
6.1 MEDIUM· v3
N/A· v2
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escapin...Show more
Shenzhen Tenda AC7 firmware version V03.03.03.01_cn and prior contain an improper output encoding vulnerability in the web management interface. User-supplied input is reflected in HTTP responses without adequate escaping, allowing injection of arbitrary HTML or JavaScript in a victim’s browser context.Show less
1Tenda
1Ac7 Firmware
Oct 20, 2025
Oct 10, 2025
7.4 HIGH· v4
9.8 CRITICAL· v3
9.0 HIGH· v2
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is...Show more
A vulnerability was determined in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/setNotUpgrade. This manipulation of the argument newVersion causes stack-based buffer overflow. The attack is possible to be carried out remotely. The exploit has been publicly disclosed and may be utilized.Show less
1Tenda
1Ac7 Firmware
Oct 9, 2025
Oct 9, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation...Show more
A vulnerability was identified in Tenda AC7 15.03.06.44. This affects an unknown function of the file /goform/saveAutoQos. The manipulation of the argument enable leads to stack-based buffer overflow. Remote exploitation of the attack is possible. The exploit is publicly available and might be used.Show less
1Tenda
1Ac7 Firmware
Feb 24, 2026
Oct 9, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based b...Show more
A vulnerability was determined in Tenda AC7 15.03.06.44. The impacted element is an unknown function of the file /goform/fast_setting_pppoe_set. Executing a manipulation of the argument Password can lead to stack-based buffer overflow. The attack may be launched remotely. The exploit has been publicly disclosed and may be utilized.Show less
1Tenda
1Ac7 Firmware
Feb 24, 2026
Oct 9, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer ove...Show more
A vulnerability was found in Tenda AC7 15.03.06.44. The affected element is an unknown function of the file /goform/WifiMacFilterSet. Performing a manipulation of the argument wifi_chkHz results in stack-based buffer overflow. The attack may be initiated remotely. The exploit has been made public and could be used.Show less
1Tenda
1Ac7 Firmware
Oct 9, 2025
Oct 9, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be la...Show more
A vulnerability has been found in Tenda AC7 15.03.06.44. Impacted is an unknown function of the file /goform/SetUpnpCfg. Such manipulation of the argument upnpEn leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
Oct 9, 2025
Oct 9, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be in...Show more
A flaw has been found in Tenda AC7 15.03.06.44. This issue affects some unknown processing of the file /goform/SetDDNSCfg. This manipulation of the argument ddnsEn causes stack-based buffer overflow. The attack can be initiated remotely. The exploit has been published and may be used.Show less
1Tenda
1Ac7 Firmware
Apr 29, 2026
Oct 9, 2025
2.1 LOW· v4
8.8 HIGH· v3
6.5 MEDIUM· v2
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launc...Show more
A vulnerability was detected in Tenda AC7 15.03.06.44. This vulnerability affects unknown code of the file /goform/AdvSetLanip. The manipulation of the argument lanIp results in command injection. It is possible to launch the attack remotely. The exploit is now public and may be used.Show less
1Tenda
2Ac18 Firmware
Ac7 Firmware
Oct 3, 2025
Aug 15, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is...Show more
A vulnerability has been found in Tenda AC7 and AC18 15.03.05.19/15.03.06.44. Affected is the function formSetSchedLed of the file /goform/SetLEDCfg. The manipulation of the argument Time leads to buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
Aug 1, 2025
Jul 22, 2025
7.4 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the arg...Show more
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function formSetMacFilterCfg of the file /goform/setMacFilterCfg of the component httpd. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
Jun 9, 2025
Jun 9, 2025
7.4 HIGH· v4
9.8 CRITICAL· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffe...Show more
A vulnerability was found in Tenda AC7 15.03.06.44 and classified as critical. This issue affects the function formSetPPTPUserList of the file /goform/setPptpUserList. The manipulation of the argument list leads to buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
Jun 9, 2025
Jun 9, 2025
7.4 HIGH· v4
9.8 CRITICAL· v3
9.0 HIGH· v2
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads...Show more
A vulnerability has been found in Tenda AC7 15.03.06.44 and classified as critical. This vulnerability affects the function fromadvsetlanip of the file /goform/AdvSetLanip. The manipulation of the argument lanMask leads to buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
May 24, 2025
May 16, 2025
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument...Show more
A vulnerability was found in Tenda AC7 15.03.06.44. It has been declared as critical. Affected by this vulnerability is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument reboot_time leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
May 24, 2025
May 16, 2025
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads...Show more
A vulnerability was found in Tenda AC7 15.03.06.44. It has been classified as critical. Affected is the function fromSafeSetMacFilter of the file /goform/setMacFilterCfg. The manipulation of the argument deviceList leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
May 27, 2025
Apr 7, 2025
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_serv...Show more
A vulnerability was found in Tenda AC7 15.03.06.44. It has been rated as critical. Affected by this issue is the function formSetPPTPServer of the file /goform/SetPptpServerCfg. The manipulation of the argument pptp_server_start_ip/pptp_server_end_ip leads to buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac7 Firmware
Apr 1, 2025
Mar 24, 2025
N/A· v4
9.8 CRITICAL· v3
N/A· v2
A stack-based buffer overflow vulnerability in Tenda AC7 V15.03.06.44 allows a remote attacker to execute arbitrary code through a stack overflow attack using the security parameter of the formWifiBasicSet function.