Smiths Medical
smiths-medical
10 CVEs • 2 products
Products (2)
Click to collapseToggle
Products (2)
Click to collapse
CVEs (10)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 7.3 HIGH· v3 7.5 HIGH· v2 A Use of Hard-coded Password issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. Telnet on the pump uses hardcoded credentials, which can be used if the pump i...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 5.6 MEDIUM· v3 6.8 MEDIUM· v2 A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump with default network configuration uses hard-coded credentials to...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 8.1 HIGH· v3 6.8 MEDIUM· v2 A Use of Hard-coded Credentials issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump contains hardcoded credentials, which are not fu...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 3.7 LOW· v3 4.3 MEDIUM· v2 A Password in Configuration File issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump stores some passwords in the configuration file, which are access...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 5.3 MEDIUM· v3 5.0 MEDIUM· v2 An Out-of-bounds Read issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump reads memory out of bounds, causing the comm...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 An Improper Certificate Validation issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The pump does not validate host certificates, leaving the pump vulnerabl...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 8.1 HIGH· v3 6.8 MEDIUM· v2 An Improper Access Control issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. The FTP server on the pump does not require authentication if the pump is config...Show more |
1Smiths Medical 1Medfusion 4000 Wireless Syringe Infusion Pump Nov 21, 2024 Feb 15, 2018 N/A· v4 8.1 HIGH· v3 6.8 MEDIUM· v2 A Classic Buffer Overflow issue was discovered in Smiths Medical Medfusion 4000 Wireless Syringe Infusion Pump, Version 1.1, 1.5, and 1.6. A third-party component used in the pump does not verify input buffer size prior...Show more |
1Smiths Medical 1Cadd Solis Medication Safety Software May 13, 2026 Feb 13, 2017 N/A· v4 8.5 HIGH· v3 6.0 MEDIUM· v2 An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. The affected software does not verify the identities at communication endpoints, which may allow a man-in-t...Show more |
1Smiths Medical 1Cadd Solis Medication Safety Software May 13, 2026 Feb 13, 2017 N/A· v4 9.9 CRITICAL· v3 9.0 HIGH· v2 An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database,...Show more |