← Back

Siemens

siemens

2,161 CVEs • 4,155 products

Products (4,155)

Click to collapse
Toggle
Jt2go
jt2go
Parasolid
parasolid
Solid Edge
solid_edge
Wincc
wincc
Sinec Nms
sinec-nms
Sinec Ins
sinec_ins
Jt Utilities
jt_utilities
Comos
comos
Simatic Wincc
simatic_wincc
Simatic Pcs 7
simatic_pcs_7
Simatic Pcs7
simatic_pcs7
Nucleus Net
nucleus_net
Pads Viewer
pads_viewer
Tecnomatix
tecnomatix
Sinema Server
sinema_server
Capital Vstar
capital_vstar

CVEs (2,161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Siemens
5En100 Ethernet Module Dnp3 Firmware
En100 Ethernet Module Iec 104 FirmwareEn100 Ethernet Module Iec 61850 Firmware+2 more
Jun 17, 2026
Jun 14, 2022
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Eth...Show more
A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition.Show less
1Siemens
1Sicam Gridedge Essential
Jun 17, 2026
Jun 14, 2022
6.9 MEDIUM· v4
4.3 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve...Show more
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application discloses password hashes of other users upon request. This could allow an authenticated user to retrieve another user's password hash.Show less
1Siemens
1Sicam Gridedge Essential
Jun 17, 2026
Jun 14, 2022
9.3 CRITICAL· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attack...Show more
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to create a new user with administrative permissions.Show less
1Siemens
1Sicam Gridedge Essential
Jun 17, 2026
Jun 14, 2022
8.6 HIGH· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attack...Show more
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected application does not require authenticated access for privileged functions. This could allow an unauthenticated attacker to change data of a user, such as credentials, in case that user's id is known.Show less
1Siemens
1Sicam Gridedge Essential
Jun 17, 2026
Jun 14, 2022
8.6 HIGH· v4
6.5 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker...Show more
A vulnerability has been identified in SICAM GridEdge (Classic) (All versions < V2.6.6). The affected software does not apply cross-origin resource sharing (CORS) restrictions for critical operations. In case an attacker tricks a legitimate user into accessing a special resource a malicious request could be executed.Show less
1Siemens
1Sinema Remote Connect Server
Jun 17, 2026
Jun 14, 2022
N/A· v4
6.1 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code....Show more
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An error message pop up window in the web interface of the affected application does not prevent injection of JavaScript code. This could allow attackers to perform reflected cross-site scripting (XSS) attacks.Show less
1Siemens
1Sinema Remote Connect Server
Jun 17, 2026
Jun 14, 2022
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of gues...Show more
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.1). An attacker in machine-in-the-middle could obtain plaintext secret values by observing length differences during a series of guesses in which a string in an HTTP request URL potentially matches an unknown string in an HTTP response body, aka a "BREACH" attack.Show less
1Siemens
1Sinema Remote Connect Server
Jun 17, 2026
Jun 14, 2022
N/A· v4
4.3 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 6220. This could aid attac...Show more
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 6220. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors.Show less
1Siemens
1Sinema Remote Connect Server
Jun 17, 2026
Jun 14, 2022
N/A· v4
4.3 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 443. This could aid attack...Show more
A vulnerability has been identified in SINEMA Remote Connect Server (All versions < V3.0 SP2). Affected application is missing general HTTP security headers in the web server configured on port 443. This could aid attackers by making the servers more prone to clickjacking, channel downgrade attacks and other similar client-based attack vectors.Show less
1Siemens
3Spectrum Power 4
Spectrum Power 7Spectrum Power Microgrid Management System
Jun 17, 2026
Jun 14, 2022
N/A· v4
8.8 HIGH· v3
5.4 MEDIUM· v2
A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker...Show more
A vulnerability has been identified in Spectrum Power 4 (All versions using Shared HIS), Spectrum Power 7 (All versions using Shared HIS), Spectrum Power MGMS (All versions using Shared HIS). An unauthenticated attacker could log into the component Shared HIS used in Spectrum Power systems by using an account with default credentials. A successful exploitation could allow the attacker to access the component Shared HIS with administrative privileges.Show less
1Siemens
17Scalance Xm408 4c Firmware
Scalance Xm408 4c L3 FirmwareScalance Xm408 8c Firmware+14 more
Jun 17, 2026
Jun 14, 2022
N/A· v4
7.5 HIGH· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5...Show more
A vulnerability has been identified in SCALANCE XM408-4C (All versions < V6.5), SCALANCE XM408-4C (L3 int.) (All versions < V6.5), SCALANCE XM408-8C (All versions < V6.5), SCALANCE XM408-8C (L3 int.) (All versions < V6.5), SCALANCE XM416-4C (All versions < V6.5), SCALANCE XM416-4C (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 1x230V (All versions < V6.5), SCALANCE XR524-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 24V (All versions < V6.5), SCALANCE XR524-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR524-8C, 2x230V (All versions < V6.5), SCALANCE XR524-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 1x230V (All versions < V6.5), SCALANCE XR526-8C, 1x230V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 24V (All versions < V6.5), SCALANCE XR526-8C, 24V (L3 int.) (All versions < V6.5), SCALANCE XR526-8C, 2x230V (All versions < V6.5), SCALANCE XR526-8C, 2x230V (L3 int.) (All versions < V6.5), SCALANCE XR528-6M (All versions < V6.5), SCALANCE XR528-6M (2HR2) (All versions < V6.5), SCALANCE XR528-6M (2HR2, L3 int.) (All versions < V6.5), SCALANCE XR528-6M (L3 int.) (All versions < V6.5), SCALANCE XR552-12M (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2) (All versions < V6.5), SCALANCE XR552-12M (2HR2, L3 int.) (All versions < V6.5). The OSPF protocol implementation in affected devices fails to verify the checksum and length fields in the OSPF LS Update messages. An unauthenticated remote attacker could exploit this vulnerability to cause interruptions in the network by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.Show less
1Siemens
18Biograph Horizon Pet/ct Systems Firmware
Magnetom Numaris X FirmwareMammomat Revelation Firmware+15 more
Jun 17, 2026
Jun 1, 2022
N/A· v4
9.8 CRITICAL· v3
9.3 HIGH· v2
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC2...Show more
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
6.9 MEDIUM· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files withou...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not restrict unauthenticated access to certain pages of the web interface. This could allow an attacker to delete log files without authentication.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
N/A· v4
6.1 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not handle uploaded files correctly. An unauthenticated attacker could take advantage of this situation to store an XSS attack, wh...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not handle uploaded files correctly. An unauthenticated attacker could take advantage of this situation to store an XSS attack, which could - when a legitimate user accesses the error logs - perform arbitrary actions in the name of the user.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
6.9 MEDIUM· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allo...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow unauthenticated users to extract internal configuration details.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
N/A· v4
5.4 MEDIUM· v3
3.5 LOW· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate input in the configuration interface. This could allow an authenticated attacker to place persistent XSS att...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly validate input in the configuration interface. This could allow an authenticated attacker to place persistent XSS attacks to perform arbitrary actions in the name of a logged user which accesses the affected views.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
5.3 MEDIUM· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allo...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). The web based management interface of affected devices does not employ special access protection for certain internal developer views. This could allow authenticated users to access critical device information.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
N/A· v4
8.1 HIGH· v3
6.8 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker...Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices use a limited range for challenges that are sent during the unencrypted challenge-response communication. An unauthenticated attacker could capture a valid challenge-response pair generated by a legitimate user, and request the webpage repeatedly to wait for the same challenge to reappear for which the correct response is known. This could allow the attacker to access the management interface of the device.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
N/A· v4
6.5 MEDIUM· v3
6.4 MEDIUM· v2
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM...Show more
A vulnerability has been identified in SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P850 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00), SICAM P855 (All versions < V3.00). Affected devices allow unauthenticated access to the web interface configuration area. This could allow an attacker to extract internal configuration details or to reconfigure network settings. However, the reconfigured settings cannot be activated unless the role of an authenticated administrator user.Show less
1Siemens
367kg8500 0aa00 0aa0 Firmware
7kg8500 0aa00 2aa0 Firmware7kg8500 0aa10 0aa0 Firmware+33 more
Jun 17, 2026
May 20, 2022
N/A· v4
6.1 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly handle the input of a GET request parameter. The provided argument is directly reflected in the web server response....Show more
A vulnerability has been identified in SICAM T (All versions < V3.0). Affected devices do not properly handle the input of a GET request parameter. The provided argument is directly reflected in the web server response. This could allow an unauthenticated attacker to perform reflected XSS attacks.Show less