1Siemens 12Simatic Cfu Diq Firmware Simatic Cfu Pa FirmwareSimatic S7 1500 Cpu Firmware+9 moreJun 17, 2026 Apr 12, 2022 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 The PROFINET (PNIO) stack, when integrated with the Interniche IP stack, improperly handles internal resources for TCP segments where the minimum TCP-Header length is less than defined. This could allow an attacker to c...Show more |
1Siemens 66Dk Standard Ethernet Controller Firmware Ek Ertec 200 FirmwareEk Ertec 200p Firmware+63 moreJun 17, 2026 Oct 10, 2019 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 Affected devices improperly handle large amounts of specially crafted UDP packets.
This could allow an unauthenticated remote attacker to trigger a denial of service condition. |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Feb 8, 2016 N/A· v4 5.3 MEDIUM· v3 5.0 MEDIUM· v2 Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to bypass a replay protection mechanism via packets on TCP port 102. |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Feb 8, 2016 N/A· v4 7.5 HIGH· v3 7.8 HIGH· v2 Siemens SIMATIC S7-1500 CPU devices before 1.8.3 allow remote attackers to cause a denial of service (STOP mode transition) via crafted packets on TCP port 102. |
1Siemens 8Simatic S7 1500 Cpu Firmware Simatic S7 1511 1 Pn CpuSimatic S7 1513 1 Pn Cpu+5 moreMay 6, 2026 Aug 17, 2014 N/A· v4 N/A· v3 7.1 HIGH· v2 Siemens SIMATIC S7-1500 CPU devices with firmware before 1.6 allow remote attackers to cause a denial of service (device restart and STOP transition) via crafted TCP packets. |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTPS packets. |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted ISO-TSAP packets. |
Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted HTTP packets. |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Mar 16, 2014 N/A· v4 N/A· v3 6.1 MEDIUM· v2 Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allow remote attackers to cause a denial of service (defect-mode transition) via crafted Profinet packets. |
The random-number generator on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 does not have sufficient entropy, which makes it easier for remote attackers to defeat cryptographic protection mechanisms...Show more |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Mar 16, 2014 N/A· v4 N/A· v3 5.8 MEDIUM· v2 Cross-site request forgery (CSRF) vulnerability on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 and SIMATIC S7-1200 CPU PLC devices with firmware before 4.0 allows remote attackers to hijack the aut...Show more |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Mar 16, 2014 N/A· v4 N/A· v3 4.3 MEDIUM· v2 Open redirect vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks...Show more |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Mar 16, 2014 N/A· v4 N/A· v3 5.8 MEDIUM· v2 The integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject headers via unspecified vectors. |
1Siemens 1Simatic S7 1500 Cpu Firmware May 6, 2026 Mar 16, 2014 N/A· v4 N/A· v3 4.3 MEDIUM· v2 Cross-site scripting (XSS) vulnerability in the integrated web server on Siemens SIMATIC S7-1500 CPU PLC devices with firmware before 1.5.0 allows remote attackers to inject arbitrary web script or HTML via unspecified v...Show more |