← Back

Siemens

siemens

2,161 CVEs • 4,155 products

Products (4,155)

Click to collapse
Toggle
Jt2go
jt2go
Parasolid
parasolid
Solid Edge
solid_edge
Wincc
wincc
Sinec Nms
sinec-nms
Sinec Ins
sinec_ins
Jt Utilities
jt_utilities
Comos
comos
Simatic Wincc
simatic_wincc
Simatic Pcs 7
simatic_pcs_7
Simatic Pcs7
simatic_pcs7
Nucleus Net
nucleus_net
Pads Viewer
pads_viewer
Tecnomatix
tecnomatix
Sinema Server
sinema_server
Capital Vstar
capital_vstar

CVEs (2,161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Siemens
14Sinamics G110
Sinamics G110dSinamics G120+11 more
Apr 29, 2026
Dec 7, 2013
N/A· v4
N/A· v3
10.0 HIGH· v2
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21...Show more
Siemens SINAMICS S/G controllers with firmware before 4.6.11 do not require authentication for FTP and TELNET sessions, which allows remote attackers to bypass intended access restrictions via TCP traffic to port (1) 21 or (2) 23.Show less
1Siemens
3Scalance X 200
Scalance X 200 Series FirmwareScalance X 200irt
Apr 29, 2026
Oct 3, 2013
N/A· v4
N/A· v3
10.0 HIGH· v2
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attacker...Show more
The integrated web server on Siemens SCALANCE X-200 switches with firmware before 4.5.0 and X-200IRT switches with firmware before 5.1.0 does not properly enforce authentication requirements, which allows remote attackers to perform administrative actions via requests to the management interface.Show less
1Siemens
9Scalance X 200
Scalance X 200 Series FirmwareScalance X 200rna+6 more
Apr 29, 2026
Sep 17, 2013
N/A· v4
N/A· v3
8.3 HIGH· v2
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier...Show more
The authentication implementation in the web server on Siemens SCALANCE X-200 switches with firmware before 5.0.0 does not use a sufficient source of entropy for generating values of random numbers, which makes it easier for remote attackers to hijack sessions by predicting a value.Show less
1Siemens
1Comos
Apr 29, 2026
Aug 9, 2013
N/A· v4
N/A· v3
7.2 HIGH· v2
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging CO...Show more
The client application in Siemens COMOS before 9.1 Update 458, 9.2 before 9.2.0.6.37, and 10.0 before 10.0.3.0.19 allows local users to gain privileges and bypass intended database-operation restrictions by leveraging COMOS project access.Show less
1Siemens
1Wincc
Apr 29, 2026
Aug 1, 2013
N/A· v4
N/A· v3
5.8 MEDIUM· v2
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMA...Show more
Open redirect vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to redirect users to arbitrary web sites and conduct phishing attacks by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.Show less
1Siemens
1Wincc
Apr 29, 2026
Aug 1, 2013
N/A· v4
N/A· v3
6.8 MEDIUM· v2
Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SI...Show more
Cross-site request forgery (CSRF) vulnerability in Siemens WinCC (TIA Portal) 11 and 12 before 12 SP1 allows remote attackers to hijack the authentication of unspecified victims by leveraging improper configuration of SIMATIC HMI panels by the WinCC product.Show less
1Siemens
17Scalance W700 Series Firmware
Scalance W744 1Scalance W744 1pro+14 more
Apr 29, 2026
Aug 1, 2013
N/A· v4
N/A· v3
10.0 HIGH· v2
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or...Show more
Unspecified vulnerability in the command-line management interface on Siemens Scalance W7xx devices with firmware before 4.5.4 allows remote attackers to bypass authentication and execute arbitrary code via a (1) SSH or (2) TELNET connection.Show less
1Siemens
17Scalance W700 Series Firmware
Scalance W744 1Scalance W744 1pro+14 more
Apr 29, 2026
Aug 1, 2013
N/A· v4
N/A· v3
6.6 MEDIUM· v2
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks...Show more
Siemens Scalance W7xx devices with firmware before 4.5.4 use the same hardcoded X.509 certificate across different customers' installations, which makes it easier for remote attackers to conduct man-in-the-middle attacks against SSL sessions by leveraging the certificate's trust relationship.Show less
1Siemens
2Enterprise Openscape Branch
Openscape Session Border Controller
Apr 29, 2026
Jul 18, 2013
N/A· v4
N/A· v3
10.0 HIGH· v2
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspec...Show more
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to execute arbitrary commands via unspecified vectors.Show less
1Siemens
2Enterprise Openscape Branch
Openscape Session Border Controller
Apr 29, 2026
Jul 18, 2013
N/A· v4
N/A· v3
7.8 HIGH· v2
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified...Show more
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to read arbitrary files via unspecified vectors.Show less
1Siemens
2Enterprise Openscape Branch
Openscape Session Border Controller
Apr 29, 2026
Jul 18, 2013
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote atta...Show more
Cross-site scripting (XSS) vulnerability in core/handleTw.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.Show less
1Siemens
2Enterprise Openscape Branch
Openscape Session Border Controller
Apr 29, 2026
Jul 18, 2013
N/A· v4
N/A· v3
7.8 HIGH· v2
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistic...Show more
core/getLog.php on the Siemens Enterprise OpenScape Branch appliance and OpenScape Session Border Controller (SBC) before 2 R0.32.0, and 7 before 7 R1.7.0, allows remote attackers to obtain sensitive server and statistics information via unspecified vectors.Show less
1Siemens
1Comos
Apr 29, 2026
Jun 18, 2013
N/A· v4
N/A· v3
4.6 MEDIUM· v2
Unspecified vulnerability in the client library in Siemens COMOS 9.2 before 9.2.0.6.10 and 10.0 before 10.0.3.0.4 allows local users to obtain unintended write access to the database by leveraging read access.
1Siemens
2Simatic Pcs7
Wincc
Apr 29, 2026
Jun 14, 2013
N/A· v4
N/A· v3
4.0 MEDIUM· v2
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, whi...Show more
The Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, exhibits different behavior for NetBIOS user names depending on whether the user account exists, which allows remote authenticated users to enumerate account names via crafted URL parameters.Show less
1Siemens
2Simatic Pcs7
Wincc
Apr 29, 2026
Jun 14, 2013
N/A· v4
N/A· v3
7.5 HIGH· v2
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to o...Show more
The login implementation in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, has a hardcoded account, which makes it easier for remote attackers to obtain access via an unspecified request.Show less
1Siemens
2Simatic Pcs7
Wincc
Apr 29, 2026
Jun 14, 2013
N/A· v4
N/A· v3
7.5 HIGH· v2
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL...Show more
SQL injection vulnerability in the login screen in the Web Navigator in Siemens WinCC before 7.2 Update 1, as used in SIMATIC PCS7 8.0 SP1 and earlier and other products, allows remote attackers to execute arbitrary SQL commands via unspecified vectors.Show less
1Siemens
7Scalance X200 4p Irt
Scalance X200irt FirmwareScalance X201 3p Irt+4 more
Apr 29, 2026
May 24, 2013
N/A· v4
N/A· v3
7.5 HIGH· v2
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS...Show more
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The implementation of SNMPv3 does not check the user credentials sufficiently. Therefore, an attacker is able to execute SNMP commands without correct credentials.Show less
1Siemens
7Scalance X200 4p Irt
Scalance X200irt FirmwareScalance X201 3p Irt+4 more
Apr 29, 2026
May 24, 2013
N/A· v4
N/A· v3
8.0 HIGH· v2
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS...Show more
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (Versions < V5.0.0 for CVE-2013-3633 and versions < V4.5.0 for CVE-2013-3634), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.1.0). The user privileges for the web interface are only enforced on client side and not properly verified on server side. Therefore, an attacker is able to execute privileged commands using an unprivileged account.Show less
1Siemens
9Simatic S7 1200 Cpu 1211c Firmware
Simatic S7 1200 Cpu 1212c FirmwareSimatic S7 1200 Cpu 1212fc Firmware+6 more
Apr 29, 2026
Apr 22, 2013
N/A· v4
N/A· v3
7.8 HIGH· v2
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to UDP port 161 (aka the SNMP port).
1Siemens
9Simatic S7 1200 Cpu 1211c Firmware
Simatic S7 1200 Cpu 1212c FirmwareSimatic S7 1200 Cpu 1212fc Firmware+6 more
Apr 29, 2026
Apr 22, 2013
N/A· v4
N/A· v3
7.8 HIGH· v2
Siemens SIMATIC S7-1200 PLCs 2.x and 3.x allow remote attackers to cause a denial of service (defect-mode transition and control outage) via crafted packets to TCP port 102 (aka the ISO-TSAP port).