← Back

Siemens

siemens

2,161 CVEs • 4,155 products

Products (4,155)

Click to collapse
Toggle
Jt2go
jt2go
Parasolid
parasolid
Solid Edge
solid_edge
Wincc
wincc
Sinec Nms
sinec-nms
Sinec Ins
sinec_ins
Jt Utilities
jt_utilities
Comos
comos
Simatic Wincc
simatic_wincc
Simatic Pcs 7
simatic_pcs_7
Simatic Pcs7
simatic_pcs7
Nucleus Net
nucleus_net
Pads Viewer
pads_viewer
Tecnomatix
tecnomatix
Sinema Server
sinema_server
Capital Vstar
capital_vstar

CVEs (2,161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Siemens
1Logo!8 Bm Fs 05 Firmware
May 13, 2026
Aug 30, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active use...Show more
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks.Show less
2Ocpfoundation
Siemens
4Local Discovery Server
Simatic Pcs7Ua .net+1 more
May 13, 2026
Aug 30, 2017
N/A· v4
8.2 HIGH· v3
6.4 MEDIUM· v2
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 a...Show more
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker.Show less
1Siemens
1Sipass Integrated
May 13, 2026
Aug 8, 2017
N/A· v4
7.8 HIGH· v3
2.1 LOW· v2
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain cre...Show more
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with local access to the SiPass integrated server or SiPass integrated client to potentially obtain credentials from the systems.Show less
1Siemens
1Sipass Integrated
May 13, 2026
Aug 8, 2017
N/A· v4
7.4 HIGH· v3
5.8 MEDIUM· v2
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to r...Show more
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication.Show less
1Siemens
1Sipass Integrated
May 13, 2026
Aug 8, 2017
N/A· v4
8.1 HIGH· v3
5.5 MEDIUM· v2
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass in...Show more
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with access to a low-privileged user account to read or write files on the file system of the SiPass integrated server over the network.Show less
1Siemens
1Sipass Integrated
May 13, 2026
Aug 8, 2017
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform...Show more
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.Show less
1Siemens
1Simatic Logon
May 13, 2026
Aug 8, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service...Show more
A vulnerability was discovered in Siemens SIMATIC Logon (All versions before V1.6) that could allow specially crafted packets sent to the SIMATIC Logon Remote Access service on port 16389/tcp to cause a Denial-of-Service condition. The service restarts automatically.Show less
1Siemens
2Ozw672 Firmware
Ozw772 Firmware
May 13, 2026
Aug 8, 2017
N/A· v4
7.4 HIGH· v3
5.8 MEDIUM· v2
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the...Show more
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker to read and manipulate data in TLS sessions while performing a man-in-the-middle (MITM) attack on the integrated web server on port 443/tcp.Show less
1Siemens
2Ozw672 Firmware
Ozw772 Firmware
May 13, 2026
Aug 8, 2017
N/A· v4
6.5 MEDIUM· v3
6.4 MEDIUM· v2
A vulnerability was discovered in Siemens OZW672 (all versions) and OZW772 (all versions) that could allow an attacker with access to port 21/tcp to access or alter historical measurement data stored on the device.
1Siemens
2Simatic Wincc Sm@rtclient
Simatic Wincc Sm@rtclient Lite
May 13, 2026
Aug 8, 2017
N/A· v4
5.4 MEDIUM· v3
4.6 MEDIUM· v2
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical acce...Show more
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2) and SIMATIC WinCC Sm@rtClient for Android Lite (All versions before V1.0.2.2). An attacker with physical access to an unlocked mobile device, that has the affected app running, could bypass the app's authentication mechanism under certain conditions.Show less
1Siemens
1Simatic Wincc Sm@rtclient
May 13, 2026
Aug 8, 2017
N/A· v4
7.4 HIGH· v3
5.8 MEDIUM· v2
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS sessio...Show more
A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack.Show less
1Siemens
1Viewport For Web Office Portal
May 13, 2026
Aug 8, 2017
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the ope...Show more
A vulnerability was discovered in Siemens ViewPort for Web Office Portal before revision number 1453 that could allow an unauthenticated remote user to upload arbitrary code and execute it with the permissions of the operating-system user running the web server by sending specially crafted network packets to port 443/TCP or port 80/TCP.Show less
1Siemens
1Xhq Server
May 13, 2026
Aug 7, 2017
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceedin...Show more
A vulnerability was discovered in Siemens XHQ server 4 and 5 (4 before V4.7.1.3 and 5 before V5.0.0.2) that could allow an authenticated low-privileged remote user to gain read access to data in the XHQ solution exceeding his configured permission level.Show less
4Debian
NetappNtp+1 more
9Clustered Data Ontap
Data OntapDebian Linux+6 more
May 13, 2026
Aug 7, 2017
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
The decodenetnum function in ntpd in NTP 4.2.x before 4.2.8p4, and 4.3.x before 4.3.77 allows remote attackers to cause a denial of service (assertion failure) via a 6 or mode 7 packet containing a long data value.
4Citrix
NetappNtp+1 more
8Clustered Data Ontap
Data OntapNtp+5 more
May 13, 2026
Aug 7, 2017
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
The rate limiting feature in NTP 4.x before 4.2.8p4 and 4.3.x before 4.3.77 allows remote attackers to have unspecified impact via a large number of crafted requests.
10Canonical
DebianFedoraproject+7 more
18Debian Linux
Enterprise Linux DesktopEnterprise Linux Hpc Node+15 more
May 13, 2026
Jul 21, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a craft...Show more
The ULOGTOD function in ntp.d in SNTP before 4.2.7p366 does not properly perform type conversions from a precision value to a double, which allows remote attackers to cause a denial of service (infinite loop) via a crafted NTP packet.Show less
1Siemens
1Simatic Cp 44x 1 Redundant Network Access Modules
May 13, 2026
Jul 7, 2017
N/A· v4
8.1 HIGH· v3
6.8 MEDIUM· v2
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process...Show more
An Improper Authentication issue was discovered in Siemens SIMATIC CP 44x-1 RNA, all versions prior to 1.4.1. An unauthenticated remote attacker may be able to perform administrative actions on the Communication Process (CP) of the RNA series module, if network access to Port 102/TCP is available and the configuration file for the CP is stored on the RNA's CPU.Show less
1Siemens
3Simatic Wincc
Simatic Wincc (tia Portal)Simatic Wincc Runtime
May 13, 2026
May 11, 2017
N/A· v4
4.9 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 befor...Show more
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface.Show less
1Siemens
16Pcs 7
Primary Setup ToolSecurity Configuration Tool+13 more
May 13, 2026
May 11, 2017
N/A· v4
6.5 MEDIUM· v3
6.1 MEDIUM· v2
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions...Show more
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover.Show less
1Siemens
79Dk Standard Ethernet Controller Firmware
Ek Ertec 200 Pn Io FirmwareEk Ertec 200p Pn Io Firmware+76 more
May 13, 2026
May 11, 2017
7.1 HIGH· v4
6.5 MEDIUM· v3
6.1 MEDIUM· v2
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PRO...Show more