1Siemens
1Desigo Insight
Jun 17, 2026
Oct 15, 2020
N/A· v4
4.3 MEDIUM· v3
4.0 MEDIUM· v2
A vulnerability has been identified in Desigo Insight (All versions). The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to r...Show more
A vulnerability has been identified in Desigo Insight (All versions). The web service does not properly apply input validation for some query parameters in a reserved area. This could allow an authenticated attacker to retrieve data via a content-based blind SQL injection attack.Show less
1Siemens
1Dca Vantage Analyzer Firmware
Jun 17, 2026
Oct 13, 2020
N/A· v4
6.8 MEDIUM· v3
4.6 MEDIUM· v2
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected d...Show more
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Affected devices use a hard-coded password to protect the onboard database. This could allow an attacker to read and or modify the onboard database. Successful exploitation requires direct physical access to the device.Show less
1Siemens
1Dca Vantage Analyzer Firmware
Jun 17, 2026
Oct 13, 2020
N/A· v4
6.8 MEDIUM· v3
7.2 HIGH· v2
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper A...Show more
A vulnerability has been identified in DCA Vantage Analyzer (All versions < V4.5 are affected by CVE-2020-7590. In addition, serial numbers < 40000 running software V4.4.0 are also affected by CVE-2020-15797). Improper Access Control could allow an unauthenticated attacker to escape from the restricted environment (“kiosk mode”) and access the underlying operating system. Successful exploitation requires direct physical access to the system.Show less
1Siemens
14Simatic S7 300 Cpu 312 Firmware
Simatic S7 300 Cpu 314 FirmwareSimatic S7 300 Cpu 315 2 Dp Firmware+11 more
Jun 17, 2026
Sep 9, 2020
N/A· v4
6.5 MEDIUM· v3
3.3 LOW· v2
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010...Show more
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.Show less
1Siemens
1Spectrum Power 4
Jun 17, 2026
Sep 9, 2020
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). If configured in an insecure manner, the web server might be susceptible to a directory listing attack.
1Siemens
1Polarion Subversion Webclient
Jun 17, 2026
Sep 9, 2020
N/A· v4
8.1 HIGH· v3
5.8 MEDIUM· v2
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious...Show more
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The web interface could allow a Cross-Site Request Forgery (CSRF) attack if an unsuspecting user is tricked into accessing a malicious link. Successful exploitation requires user interaction by a legitimate user, who must be authenticated to the web interface. A successful attack could allow an attacker to trigger actions via the web interface that the legitimate user is allowed to perform. This could allow the attacker to read or modify contents of the web application.Show less
1Siemens
1Polarion Subversion Webclient
Jun 17, 2026
Sep 9, 2020
N/A· v4
6.1 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed in...Show more
A vulnerability has been identified in Polarion Subversion Webclient (All versions). The Polarion subversion web application does not filter user input in a way that prevents Cross-Site Scripting. If a user is enticed into passing specially crafted, malicious input to the web client (e.g. by clicking on a malicious URL with embedded JavaScript), then JavaScript code can be returned and may then be executed by the user’s client. Various actions could be triggered by running malicious JavaScript code.Show less
1Siemens
1Simatic Hmi United Comfort Panels Firmware
Jun 17, 2026
Sep 9, 2020
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a...Show more
A vulnerability has been identified in SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently validate authentication attempts as the information given can be truncated to match only a set number of characters versus the whole provided string. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.Show less
1Siemens
4Simatic Hmi Basic Panels 2nd Generation Firmware
Simatic Hmi Comfort Panels FirmwareSimatic Hmi Mobile Panels Firmware+1 more
Jun 17, 2026
Sep 9, 2020
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Pa...Show more
A vulnerability has been identified in SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions < V16), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions <= V16), SIMATIC HMI Mobile Panels (All versions <= V16), SIMATIC HMI Unified Comfort Panels (All versions <= V16). Affected devices insufficiently block excessive authentication attempts. This could allow a remote attacker to discover user passwords and obtain access to the Sm@rt Server via a brute-force attack.Show less
1Siemens
1Siveillance Video Client
Jun 17, 2026
Sep 9, 2020
N/A· v4
5.3 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in Siveillance Video Client (All versions). In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext....Show more
A vulnerability has been identified in Siveillance Video Client (All versions). In environments where Windows NTLM authentication is enabled the affected client application transmits usernames to the server in cleartext. This could allow an attacker in a privileged network position to obtain valid adminstrator login names and use this information to launch further attacks.Show less
1Siemens
1Spectrum Power 4
Jun 17, 2026
Sep 9, 2020
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in Spectrum Power 4 (All versions < V4.70 SP8). Insecure storage of sensitive information in the configuration files could allow the retrieval of user names.
1Siemens
1License Management Utility
Jun 17, 2026
Sep 9, 2020
N/A· v4
7.8 HIGH· v3
7.2 HIGH· v2
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration...Show more
A vulnerability has been identified in License Management Utility (LMU) (All versions < V2.4). The lmgrd service of the affected application is executed with local SYSTEM privileges on the server while its configuration can be modified by local users. The vulnerability could allow a local authenticated attacker to execute arbitrary commands on the server with local SYSTEM privileges.Show less
1Siemens
1Simatic Rtls Locating Manager
Jun 17, 2026
Sep 9, 2020
N/A· v4
7.8 HIGH· v3
7.2 HIGH· v2
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This cou...Show more
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). Multiple services of the affected application are executed with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to inject arbitrary commands that are execeuted instead of the legitimate service.Show less
1Siemens
1Simatic Rtls Locating Manager
Jun 17, 2026
Sep 9, 2020
N/A· v4
7.8 HIGH· v3
7.2 HIGH· v2
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands t...Show more
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The directory of service executables of the affected application could allow a local attacker to include arbitrary commands that are executed with SYSTEM privileges when the system restarts.Show less
1Siemens
1Simatic Rtls Locating Manager
Jun 17, 2026
Sep 9, 2020
N/A· v4
7.3 HIGH· v3
4.4 MEDIUM· v2
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary command...Show more
A vulnerability has been identified in SIMATIC RTLS Locating Manager (All versions < V2.10.2). The start-stop scripts for the services of the affected application could allow a local attacker to include arbitrary commands that are executed when services are started or stopped interactively by system administrators.Show less
1Siemens
1Automation License Manager
Jun 17, 2026
Aug 14, 2020
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing so...Show more
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0.8). The application does not properly validate the users' privileges when executing some operations, which could allow a user with low permissions to arbitrary modify files that should be protected against writing.Show less
1Siemens
1Sicam A8000 Firmware
Jun 17, 2026
Aug 14, 2020
N/A· v4
9.6 CRITICAL· v3
6.8 MEDIUM· v2
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log m...Show more
A vulnerability has been identified in SICAM WEB firmware for SICAM A8000 RTUs (All versions < V05.30). The login screen does not sufficiently sanitize input, which enables an attacker to generate specially crafted log messages. If an unsuspecting victim views the log messages via the web browser, these log messages might be interpreted and executed as code by the web application. This Cross-Site-Scripting (XSS) vulnerability might compromize the confidentiality, integrity and availability of the web application.Show less
1Siemens
2Desigo Consumption Control
Desigo Consumption Control Compact
Jun 17, 2026
Aug 14, 2020
N/A· v4
9.8 CRITICAL· v3
9.3 HIGH· v2
A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote...Show more
A vulnerability has been identified in Desigo CC (V4.x), Desigo CC (V3.x), Desigo CC Compact (V4.x), Desigo CC Compact (V3.x). Affected applications are delivered with a 3rd party component (BIRT) that contains a remote code execution vulnerability if the Advanced Reporting Engine is enabled. The vulnerability could allow a remote unauthenticated attacker to execute arbitrary commands on the server with SYSTEM privileges.Show less
1Siemens
1Logo! 8 Bm Firmware
Jun 17, 2026
Jul 14, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerabili...Show more
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (V1.81.01 - V1.81.03), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.01), LOGO! 8 BM (incl. SIPLUS variants) (V1.82.02). A buffer overflow vulnerability exists in the Web Server functionality of the device. A remote unauthenticated attacker could send a specially crafted HTTP request to cause a memory corruption, potentially resulting in remote code execution.Show less
1Siemens
6Simatic Hmi Basic Panels 1st Generation
Simatic Hmi Basic Panels 2nd GenerationSimatic Hmi Comfort Panels Firmware+3 more
Jun 17, 2026
Jul 14, 2020
N/A· v4
6.5 MEDIUM· v3
3.3 LOW· v2
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort P...Show more
A vulnerability has been identified in SIMATIC HMI Basic Panels 1st Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Basic Panels 2nd Generation (incl. SIPLUS variants) (All versions), SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions), SIMATIC HMI KTP700F Mobile Arctic (All versions), SIMATIC HMI Mobile Panels 2nd Generation (All versions), SIMATIC WinCC Runtime Advanced (All versions). Unencrypted communication between the configuration software and the respective device could allow an attacker to capture potential plain text communication and have access to sensitive information.Show less