← Back

Siemens

siemens

2,161 CVEs • 4,155 products

Products (4,155)

Click to collapse
Toggle
Jt2go
jt2go
Parasolid
parasolid
Solid Edge
solid_edge
Wincc
wincc
Sinec Nms
sinec-nms
Sinec Ins
sinec_ins
Jt Utilities
jt_utilities
Comos
comos
Simatic Wincc
simatic_wincc
Simatic Pcs 7
simatic_pcs_7
Simatic Pcs7
simatic_pcs7
Nucleus Net
nucleus_net
Pads Viewer
pads_viewer
Tecnomatix
tecnomatix
Sinema Server
sinema_server
Capital Vstar
capital_vstar

CVEs (2,161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
3Arm
DebianSiemens
8Debian Linux
Logo! Cmr2020 FirmwareLogo! Cmr2040 Firmware+5 more
Jun 17, 2026
Aug 23, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered va...Show more
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). A NULL algorithm parameters entry looks identical to an array of REAL (size zero) and thus the certificate is considered valid. However, if the parameters do not match in any way, then the certificate should be considered invalid.Show less
3Arm
DebianSiemens
8Debian Linux
Logo! Cmr2020 FirmwareLogo! Cmr2040 Firmware+5 more
Jun 17, 2026
Aug 23, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to de...Show more
An issue was discovered in Mbed TLS before 2.25.0 (and before 2.16.9 LTS and before 2.7.18 LTS). The calculations performed by mbedtls_mpi_exp_mod are not limited; thus, supplying overly large parameters could lead to denial of service when generating Diffie-Hellman key pairs.Show less
1Siemens
1Sinema Remote Connect
Jun 17, 2026
Aug 19, 2021
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to...Show more
A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.0 SP1). Affected devices allow to modify configuration settings over an unauthenticated channel. This could allow a local attacker to escalate privileges and execute own code on the device.Show less
2Hcc Embedded
Siemens
3Nichestack
Sentron 3wa Com190 FirmwareSentron 3wl Com35 Firmware
Jun 17, 2026
Aug 19, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in tcp_rcv() in nptcp.c in HCC embedded InterNiche 4.0.1. The TCP header processing code doesn't sanitize the value of the IP total length field (header length + data length). With a crafted IP pa...Show more
An issue was discovered in tcp_rcv() in nptcp.c in HCC embedded InterNiche 4.0.1. The TCP header processing code doesn't sanitize the value of the IP total length field (header length + data length). With a crafted IP packet, an integer overflow occurs whenever the value of the IP data length is calculated by subtracting the length of the header from the total length of the IP packet.Show less
2Hcc Embedded
Siemens
3Nichestack
Sentron 3wa Com190 FirmwareSentron 3wl Com35 Firmware
Jun 17, 2026
Aug 19, 2021
N/A· v4
9.1 CRITICAL· v3
6.4 MEDIUM· v2
An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to det...Show more
An issue was discovered in HCC Nichestack 3.0. The code that generates Initial Sequence Numbers (ISNs) for TCP connections derives the ISN from an insufficiently random source. As a result, an attacker may be able to determine the ISN of current and future TCP connections and either hijack existing ones or spoof future ones. (Proper ISN generation should aim to follow at least the specifications outlined in RFC 6528.)Show less
2Hcc Embedded
Siemens
3Nichestack
Sentron 3wa Com190 FirmwareSentron 3wl Com35 Firmware
Jun 17, 2026
Aug 19, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP c...Show more
An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).Show less
2Hcc Embedded
Siemens
27km9300 0ae02 0aa0 Firmware
Nichestack
Jun 17, 2026
Aug 19, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size i...Show more
An issue was discovered in HCC Nichestack 3.0. The code that parses ICMP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the ICMP checksum. When the IP payload size is set to be smaller than the size of the IP header, the ICMP checksum computation function may read out of bounds, causing a Denial-of-Service.Show less
5Debian
NetappNodejs+2 more
7Debian Linux
GraalvmJd Edwards Enterpriseone Tools+4 more
Jun 17, 2026
Aug 16, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
Node.js before 16.6.1, 14.17.5, and 12.22.5 is vulnerable to a use after free attack where an attacker might be able to exploit the memory corruption, to change process behavior.
5Debian
NetappNodejs+2 more
8Debian Linux
GraalvmJd Edwards Enterpriseone Tools+5 more
Jun 17, 2026
Aug 16, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
If the Node.js https API was used incorrectly and "undefined" was in passed for the "rejectUnauthorized" parameter, no error was returned and connections to servers with an expired certificate would have been accepted.
4Netapp
NodejsOracle+1 more
10Active Iq Unified Manager
GraalvmMysql Cluster+7 more
Jun 17, 2026
Aug 16, 2021
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to Remote Code Execution, XSS, Application crashes due to missing input validation of host names returned by Domain Name Servers in Node.js dns library which can...Show more
Node.js before 16.6.0, 14.17.4, and 12.22.4 is vulnerable to Remote Code Execution, XSS, Application crashes due to missing input validation of host names returned by Domain Name Servers in Node.js dns library which can lead to output of wrong hostnames (leading to Domain Hijacking) and injection vulnerabilities in applications using the library.Show less
1Siemens
1Solid Edge Se2021 Firmware
Jun 17, 2026
Aug 10, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an u...Show more
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library lacks proper validation while parsing user-supplied OBJ files that could cause an out of bounds access to an uninitialized pointer. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13775)Show less
1Siemens
1Solid Edge Se2021 Firmware
Jun 17, 2026
Aug 10, 2021
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use...Show more
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). The PSKERNEL.dll library in affected application lacks proper validation while parsing user-supplied OBJ files that could lead to a use-after-free condition. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-13777)Show less
1Siemens
1Solid Edge Se2021 Firmware
Jun 17, 2026
Aug 10, 2021
N/A· v4
5.5 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary...Show more
A vulnerability has been identified in Solid Edge SE2021 (All Versions < SE2021MP7). An XML external entity injection vulnerability in the underlying XML parser could cause the affected application to disclose arbitrary files to remote attackers by loading a specially crafted xml file.Show less
1Siemens
2Simatic S7 1200 Cpu Firmware
Simatic Step 7 (tia Portal)
Jun 17, 2026
Aug 10, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could all...Show more
A vulnerability has been identified in SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (V4.5.0). Affected devices fail to authenticate against configured passwords when provisioned using TIA Portal V13. This could allow an attacker using TIA Portal V13 or later versions to bypass authentication and download arbitrary programs to the PLC. The vulnerability does not occur when TIA Portal V13 SP1 or any later version was used to provision the device.Show less
1Siemens
2Jt2go
Teamcenter Visualization
Jun 17, 2026
Aug 10, 2021
N/A· v4
3.3 LOW· v3
4.3 MEDIUM· v2
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-sup...Show more
A vulnerability has been identified in JT2Go (All versions < V13.2.0.2), Teamcenter Visualization (All versions < V13.2.0.2). The plmxmlAdapterSE70.dll library in affected applications lacks proper validation of user-supplied data when parsing PAR files. This could result in an out of bounds read past the end of an allocated buffer. An attacker could leverage this vulnerability to leak information in the context of the current process. (ZDI-CAN-13405)Show less
1Siemens
1Sinec Network Management System
Jun 17, 2026
Aug 10, 2021
N/A· v4
7.2 HIGH· v3
9.0 HIGH· v2
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2). The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authe...Show more
A vulnerability has been identified in SINEC NMS (All versions < V1.0 SP2). The affected application incorrectly neutralizes special elements when creating batch operations which could lead to command injection. An authenticated remote attacker with administrative privileges could exploit this vulnerability to execute arbitrary code on the system with system privileges.Show less
1Siemens
2Jt2go
Teamcenter Visualization
Jun 17, 2026
Aug 10, 2021
N/A· v4
5.5 MEDIUM· v3
4.3 MEDIUM· v2
A vulnerability has been identified in JT2Go (All versions < V13.2.0.1), Teamcenter Visualization (All versions < V13.2.0.1). When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the a...Show more
A vulnerability has been identified in JT2Go (All versions < V13.2.0.1), Teamcenter Visualization (All versions < V13.2.0.1). When parsing specially crafted CGM Files, a NULL pointer deference condition could cause the application to crash. The application must be restarted to restore the service. An attacker could leverage this vulnerability to cause a Denial-of-Service condition in the application.Show less
1Siemens
1Automation License Manager
Jun 17, 2026
Aug 10, 2021
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected syste...Show more
A vulnerability has been identified in Automation License Manager 5 (All versions), Automation License Manager 6 (All versions < V6.0 SP9 Update 2). Sending specially crafted packets to port 4410/tcp of an affected system could lead to extensive memory being consumed and as such could cause a denial-of-service preventing legitimate users from using the system.Show less
1Siemens
56Cpu1510sp F 1 Firmware
Cpu 1211c FirmwareCpu 1212c Firmware+53 more
Jun 17, 2026
Aug 10, 2021
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (...Show more
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC S7 PLCSIM Advanced (All versions > V2 < V4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (Version V4.4), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions > V2.5 < V2.9.2), SIMATIC S7-1500 Software Controller (All versions > V2.5 < V21.9), TIM 1531 IRC (incl. SIPLUS NET variants) (Version V2.1). Due to an incorrect authorization check in the affected component, an attacker could extract information about access protected PLC program variables over port 102/tcp from an affected device when reading multiple attributes at once.Show less
5Debian
FedoraprojectGolang+2 more
5Debian Linux
FedoraGo+2 more
Jun 17, 2026
Aug 8, 2021
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Go before 1.15.15 and 1.16.x before 1.16.7 has a race condition that can lead to a net/http/httputil ReverseProxy panic upon an ErrAbortHandler abort.