CVEs (7)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Schneider Electric 2Easylogic T150 Firmware Saitel Dp FirmwareJul 14, 2026 Jun 25, 2026 6.7 MEDIUM· v4 4.4 MEDIUM· v3 N/A· v2 CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account compromise when an attacker with privileged local access reads...Show more |
1Schneider Electric 2Easylogic T150 Firmware Saitel Dp FirmwareJul 14, 2026 Jun 25, 2026 8.7 HIGH· v4 7.5 HIGH· v3 N/A· v2 CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated attacker accesses credentials stored within firmware or system fi...Show more |
3Rockwellautomation Schneider ElectricXylem17Aadvance Controller Easergy C5 FirmwareEasergy T300 Firmware+14 moreJun 17, 2026 Mar 18, 2022 N/A· v4 5.5 MEDIUM· v3 2.1 LOW· v2 Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x stores the password in plaintext in a file that is in the same directory as the executable file. ISaGRAF Runtime reads the file and saves the data in a variable wi...Show more |
3Rockwellautomation Schneider ElectricXylem17Aadvance Controller Easergy C5 FirmwareEasergy T300 Firmware+14 moreJun 17, 2026 Mar 18, 2022 N/A· v4 6.7 MEDIUM· v3 4.6 MEDIUM· v2 Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x searches for and loads DLLs as dynamic libraries. Uncontrolled loading of dynamic libraries could allow a local, unauthenticated attacker to execute arbitrary code...Show more |
3Rockwellautomation Schneider ElectricXylem17Aadvance Controller Easergy C5 FirmwareEasergy T300 Firmware+14 moreJun 17, 2026 Mar 18, 2022 N/A· v4 6.5 MEDIUM· v3 4.3 MEDIUM· v2 Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of enc...Show more |
3Rockwellautomation Schneider ElectricXylem17Aadvance Controller Easergy C5 FirmwareEasergy T300 Firmware+14 moreJun 17, 2026 Mar 18, 2022 N/A· v4 8.8 HIGH· v3 9.3 HIGH· v2 ISaGRAF Workbench communicates with Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x using TCP/IP. This communication protocol provides various file system operations, as well as the uploading of applications. Da...Show more |
3Rockwellautomation Schneider ElectricXylem17Aadvance Controller Easergy C5 FirmwareEasergy T300 Firmware+14 moreJun 17, 2026 Mar 18, 2022 N/A· v4 9.8 CRITICAL· v3 9.3 HIGH· v2 Some commands used by the Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x eXchange Layer (IXL) protocol perform various file operations in the file system. Since the parameter pointing to the file name is not ch...Show more |