← Back

Powerchute Serial Shutdown

powerchute_serial_shutdown

Vendor: Schneider Electric • 7 CVEs

CVEs (7)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
6.5 MEDIUM· v3
N/A· v2
CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Admin user floods the system with POST /helpabout requests.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security check request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
4.3 MEDIUM· v3
N/A· v2
CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a Web Admin user alters the POST /logsettings request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with dif...Show more
CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by performing an arbitrary number of authentication attempts with different credentials on a sequence of requests to multiple endpoints.Show less
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
2.4 LOW· v4
5.0 MEDIUM· v3
N/A· v2
CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user executes a malicious file provided by an attacker.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
5.3 MEDIUM· v4
4.3 MEDIUM· v3
N/A· v2
CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admin user alters the POST /setPCBEDesc request payload.
1Schneider Electric
1Powerchute Serial Shutdown
Jun 17, 2026
Apr 14, 2026
6.9 MEDIUM· v4
6.1 MEDIUM· v3
N/A· v2
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep r...Show more
CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with text data when a Web Admin user alters the POST /REST/upssleep request payload.Show less