← Back

Modicon M340 Bmxp3420302 Firmware

modicon_m340_bmxp3420302_firmware

Vendor: Schneider Electric • 28 CVEs

CVEs (28)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability exists in the web services to process SOAP requests in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow result in a buffer overflow.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
An authorization bypass vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. Requests to CGI functions allow malicious users to bypass authorization.
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (ins...Show more
A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied.Show less
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the passwor...Show more
Vulnerable hash algorithms exists in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. The algorithm used to encrypt the password is vulnerable to hash collision attacks.Show less
1Schneider Electric
57140cpu31110 Firmware
140cpu31110c Firmware140cpu43412u Firmware+54 more
Jun 17, 2026
Apr 18, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules.
1Schneider Electric
15Bmxnoc0401 Firmware
Bmxnoe0100 FirmwareBmxnoe0110 Firmware+12 more
May 13, 2026
Jun 30, 2017
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H,...Show more
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.Show less
1Schneider Electric
43171ccc96020 Firmware
171ccc96020c Firmware171ccc96030 Firmware+40 more
May 6, 2026
Oct 3, 2014
N/A· v4
N/A· v3
10.0 HIGH· v2
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 be...Show more
Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request.Show less