CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Schneider Electric 2Ecostruxure Control Expert Ecostruxure Process ExpertDec 11, 2024 Feb 14, 2024 N/A· v4 7.7 HIGH· v3 N/A· v2
CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause unauthorized
access to a project file protected with application password when opening the file with
EcoStruxure Control Expert.
|
1Schneider Electric 46Ecostruxure Control Expert Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+43 moreJan 23, 2025 Feb 14, 2024 N/A· v4 8.1 HIGH· v3 N/A· v2 CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when cond...Show more |
1Schneider Electric 2Ecostruxure Control Expert Ecostruxure Process ExpertDec 11, 2024 Feb 14, 2024 N/A· v4 7.1 HIGH· v3 N/A· v2 CWE-522: Insufficiently Protected Credentials vulnerability exists that could cause unauthorized access to the project file in EcoStruxure Control Expert when a local user tampers with the memory of the engineering work...Show more |
1Schneider Electric 1Ecostruxure Control Expert Nov 21, 2024 Apr 18, 2023 N/A· v4 8.8 HIGH· v3 N/A· v2 A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided through the web endpoints. Affected Products: EcoStruxure Co...Show more |
1Schneider Electric 1Ecostruxure Control Expert Nov 21, 2024 Apr 18, 2023 N/A· v4 5.5 MEDIUM· v3 N/A· v2 A CWE-269: Improper Privilege Management vulnerability exists that could cause a local user to perform a denial of service through the console server service that is part of EcoStruxure Control Expert. Affected Products...Show more |
1Schneider Electric 37Ecostruxure Control Expert Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+34 moreNov 21, 2024 Jan 31, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: Eco...Show more |
1Schneider Electric 55Ecostruxure Control Expert Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+52 moreNov 21, 2024 Jan 30, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when a malicious project file is l...Show more |
1Schneider Electric 1Ecostruxure Control Expert Nov 21, 2024 Sep 13, 2022 N/A· v4 5.5 MEDIUM· v3 N/A· v2 A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products:...Show more |
1Schneider Electric 36Ecostruxure Control Expert Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+33 moreNov 21, 2024 Sep 12, 2022 N/A· v4 9.8 CRITICAL· v3 N/A· v2 A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: Eco...Show more |
2Att Schneider Electric4Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnect+1 moreNov 21, 2024 Apr 14, 2022 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE...Show more |
1Schneider Electric 3Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnectNov 21, 2024 Apr 13, 2022 N/A· v4 7.8 HIGH· v3 9.3 HIGH· v2 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution o...Show more |
1Schneider Electric 2Ecostruxure Control Expert Ecostruxure Process ExpertNov 21, 2024 Mar 9, 2022 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to...Show more |
1Schneider Electric 1Ecostruxure Control Expert Nov 21, 2024 Mar 9, 2022 N/A· v4 5.9 MEDIUM· v3 4.3 MEDIUM· v2 A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an a...Show more |
1Schneider Electric 3Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnectNov 21, 2024 Jul 14, 2021 N/A· v4 5.5 MEDIUM· v3 2.1 LOW· v2 Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more |
1Schneider Electric 3Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnectNov 21, 2024 Jul 14, 2021 N/A· v4 5.5 MEDIUM· v3 2.1 LOW· v2 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more |
1Schneider Electric 3Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnectNov 21, 2024 Jul 14, 2021 N/A· v4 7.1 HIGH· v3 3.6 LOW· v2 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more |
1Schneider Electric 32Ecostruxure Control Expert Ecostruxure Process ExpertModicon M340 Bmxp341000 Firmware+29 moreMay 29, 2026 Jul 14, 2021 N/A· v4 9.1 CRITICAL· v3 6.4 MEDIUM· v2 Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Exper...Show more |
1Schneider Electric 3Ecostruxure Control Expert Ecostruxure Process ExpertRemoteconnectNov 21, 2024 Jul 14, 2021 N/A· v4 7.1 HIGH· v3 3.6 LOW· v2 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all vers...Show more |
1Schneider Electric 2Ecostruxure Control Expert Unity ProNov 21, 2024 Dec 11, 2020 N/A· v4 8.6 HIGH· v3 6.8 MEDIUM· v2 A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software...Show more |
1Schneider Electric 1Ecostruxure Control Expert Nov 21, 2024 Nov 19, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC si...Show more |