CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Oct 14, 2025 8.5 HIGH· v4 7.8 HIGH· v3 N/A· v2 A security issue exists within the Rockwell Automation Driver Package x64 Microsoft Installer File (MSI) repair functionality, installed with FTLinx. Authenticated attackers with valid Windows Users credentials can initi...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Oct 14, 2025 8.5 HIGH· v4 7.8 HIGH· v3 N/A· v2 A security issue exists within the x86 Microsoft Installer File (MSI), installed with FTLinx. Authenticated attackers with valid Windows user credentials can initiate a repair and hijack the resulting console window. Thi...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Aug 14, 2025 8.4 HIGH· v4 9.1 CRITICAL· v3 N/A· v2 A security issue exists within the FactoryTalk Linx Network Browser. By modifying the process.env.NODE_ENV to ‘development’, the attacker can disable FTSP token validation. This bypass allows access to create, update, an...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Oct 13, 2023 N/A· v4 9.1 CRITICAL· v3 N/A· v2 FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage o...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Dec 29, 2020 N/A· v4 5.5 MEDIUM· v3 2.1 LOW· v2 An attacker-controlled memory allocation size can be passed to the C++ new operator in the CServerManager::HandleBrowseLoadIconStreamRequest in messaging.dll. This can be done by sending a specially crafted message to 12...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Dec 29, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 An attacker-controlled memory allocation size can be passed to the C++ new operator in RnaDaSvr.dll by sending a specially crafted ConfigureItems message to TCP port 4241. This will cause an unhandled exception, resultin...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Dec 29, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 An attacker can craft and send an OpenNamespace message to port 4241 with valid session-id that triggers an unhandled exception in CFTLDManager::HandleRequest function in RnaDaSvr.dll, resulting in process termination. O...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Nov 26, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious set attribute requests, which could result in the l...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Nov 26, 2020 N/A· v4 7.5 HIGH· v3 7.8 HIGH· v2 A flaw exists in the Ingress/Egress checks routine of FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to specifically craft a malicious packet resulting in a den...Show more |
1Rockwellautomation 1Factorytalk Linx Jun 17, 2026 Nov 26, 2020 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 A heap overflow vulnerability exists within FactoryTalk Linx Version 6.11 and prior. This vulnerability could allow a remote, unauthenticated attacker to send malicious port ranges, which could result in remote code exec...Show more |
1Rockwellautomation 2Factorytalk Linx Rslinx ClassicJun 17, 2026 Jun 15, 2020 N/A· v4 7.5 HIGH· v3 7.8 HIGH· v2 FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryT...Show more |
1Rockwellautomation 2Factorytalk Linx Rslinx ClassicJun 17, 2026 Jun 15, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryT...Show more |
1Rockwellautomation 2Factorytalk Linx Rslinx ClassicJun 17, 2026 Jun 15, 2020 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryT...Show more |
1Rockwellautomation 2Factorytalk Linx Rslinx ClassicJun 17, 2026 Jun 15, 2020 N/A· v4 8.1 HIGH· v3 5.5 MEDIUM· v2 FactoryTalk Linx versions 6.00, 6.10, and 6.11, RSLinx Classic v4.11.00 and prior,Connected Components Workbench: Version 12 and prior, ControlFLASH: Version 14 and later, ControlFLASH Plus: Version 1 and later, FactoryT...Show more |