CVE-2023-29464
9.1
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Exploitability: 3.9 / Impact: 5.2
Source: NVD
Description
FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx over the common industrial protocol.
Affected (2)
Products: Rockwellautomation: Factorytalk Linx
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Version 6.20 |
Related CWEs
CWE-20
Improper Input Validation
The product receives input or data, but it does
not validate or incorrectly validates that the input has the
properties that are required to process the data safely and
correctly.
CWE-787
Out-of-bounds Write
The product writes data past the end, or before the beginning, of the intended buffer.
References (2)
Source: PSIRT@rockwellautomation.com
Permissions RequiredVendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Permissions RequiredVendor Advisory
Timeline