← Back
CWE-798

1,746 CVEs • Abstraction: Base • Likelihood of Exploit: High

Use of Hard-coded Credentials

The product contains hard-coded credentials, such as a password or cryptographic key.

JSON object

Loading...

CVEs (1,746)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axzyxel password for the livedbuser account.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has the axiros password for the root account.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded RSA SSH key for the root account within the /opt/mysql chroot directory tree.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded DSA SSH key for the root account within the /opt/mysql chroot directory tree.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded RSA SSH key for the root account within the /opt/axess chroot directory tree.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded ECDSA SSH key for the root account within the /opt/axess chroot directory tree.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded DSA SSH key for the root account within the /opt/axess chroot directory tree.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded RSA SSH key for the root account.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded ECDSA SSH key for the root account.
1Zyxel
1Cloudcnm Secumanager
Jun 17, 2026
Jun 29, 2020
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
Zyxel CloudCNM SecuManager 3.1.0 and 3.1.1 has a hardcoded DSA SSH key for the root account.
1Netapp
1Hci H610s Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
The NetApp HCI H610C, H615C and H610S Baseboard Management Controllers (BMC) are shipped with a documented default account and password that should be changed during the initial node setup. During upgrades to Element 11....Show more
The NetApp HCI H610C, H615C and H610S Baseboard Management Controllers (BMC) are shipped with a documented default account and password that should be changed during the initial node setup. During upgrades to Element 11.8 and 12.0 or the Compute Firmware Bundle 12.2.92 the BMC account password on the H610C, H615C and H610S platforms is reset to the default documented value which could allow remote attackers to cause a Denial of Service (DoS).Show less
1Baxter
1Sigma Spectrum Infusion System Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24), when used with a Baxter Spectrum v8.x (model 35700BAX2) in a factory-default wireless configuration enables an FTP service with hard-coded credentials.
1Baxter
1Sigma Spectrum Infusion System Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials.
1Baxter
1Sigma Spectrum Infusion System Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
2.4 LOW· v3
2.1 LOW· v2
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide...Show more
Baxter Sigma Spectrum Infusion Pumps Sigma Spectrum Infusion System v's6.x model 35700BAX & Baxter Spectrum Infusion System v's8.x model 35700BAX2 contain hardcoded passwords when physically entered on the keypad provide access to biomedical menus including device settings, view calibration values, network configuration of Sigma Spectrum WBM if installed.Show less
1Baxter
2Prismaflex Firmware
Prismax Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
4.9 MEDIUM· v3
3.6 LOW· v2
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and n...Show more
Baxter PrismaFlex all versions, PrisMax all versions prior to 3.x, The PrismaFlex device contains a hard-coded service password that provides access to biomedical information, device settings, calibration settings, and network configuration. This could allow an attacker to modify device settings and calibration.Show less
1Baxter
2Em1200 Firmware
Em2400 Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 V...Show more
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 have hard-coded administrative account credentials for the ExactaMix operating system. Successful exploitation of this vulnerability may allow an attacker who has gained unauthorized access to system resources, including access to execute software or to view/update files, directories, or system configuration. This could allow an attacker with network access to view sensitive data including PHI.Show less
1Baxter
2Em1200 Firmware
Em2400 Firmware
Jun 17, 2026
Jun 29, 2020
N/A· v4
6.1 MEDIUM· v3
3.6 LOW· v2
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Ve...Show more
Baxter ExactaMix EM 2400 & EM 1200, Versions ExactaMix EM2400 Versions 1.10, 1.11, 1.13, 1.14, ExactaMix EM1200 Versions 1.1, 1.2, 1.4, 1.5, Baxter ExactaMix EM 2400 Versions 1.10, 1.11, and 1.13, and ExactaMix EM1200 Versions 1.1, 1.2, and 1.4 have hard-coded administrative account credentials for the ExactaMix application. Successful exploitation of this vulnerability may allow an attacker with physical access to gain unauthorized access to view/update system configuration or data. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI.Show less
3Easyrobotics
Mobile Industrial RobotsUvd Robots
10Er Flex Firmware
Er Lite FirmwareEr One Firmware+7 more
Jun 17, 2026
Jun 24, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is t...Show more
The password for the safety PLC is the default and thus easy to find (in manuals, etc.). This allows a manipulated program to be uploaded to the safety PLC, effectively disabling the emergency stop in case an object is too close to the robot. Navigation and any other components dependent on the laser scanner are not affected (thus it is hard to detect before something happens) though the laser scanner configuration can also be affected altering further the safety of the device.Show less
4Aliasrobotics
Enabled RoboticsMobile Industrial Robotics+1 more
10Er Flex Firmware
Er Lite FirmwareEr One Firmware+7 more
Jun 17, 2026
Jun 24, 2020
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface defaul...Show more
Out of the wired and wireless interfaces within MiR100, MiR200 and other vehicles from the MiR fleet, it's possible to access the Control Dashboard on a hardcoded IP address. Credentials to such wireless interface default to well known and widely spread users (omitted) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. This flaw allows cyber attackers to take control of the robot remotely and make use of the default user interfaces MiR has created, lowering the complexity of attacks and making them available to entry-level attackers. More elaborated attacks can also be established by clearing authentication and sending network requests directly. We have confirmed this flaw in MiR100 and MiR200 but according to the vendor, it might also apply to MiR250, MiR500 and MiR1000.Show less
4Aliasrobotics
Enabled RoboticsMobile Industrial Robotics+1 more
10Er Flex Firmware
Er Lite FirmwareEr One Firmware+7 more
Jun 17, 2026
Jun 24, 2020
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point defa...Show more
One of the wireless interfaces within MiR100, MiR200 and possibly (according to the vendor) other MiR fleet vehicles comes pre-configured in WiFi Master (Access Point) mode. Credentials to such wireless Access Point default to well known and widely spread SSID (MiR_RXXXX) and passwords (omitted). This information is also available in past User Guides and manuals which the vendor distributed. We have confirmed this flaw in MiR100 and MiR200 but it might also apply to MiR250, MiR500 and MiR1000.Show less