CWE-1299
10 CVEs • Abstraction: Base
Missing Protection Mechanism for Alternate Hardware Interface
The lack of protections on alternate paths to access control-protected assets (such as unprotected shadow registers and other external facing unguarded interfaces) allows an attacker to bypass existing protections to the asset that are only performed against the primary path.
CVEs (10)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
Missing protection mechanism for alternate hardware interface in the Intel(R) Quick Assist Technology for some Intel(R) Platforms within Ring 0: Kernel may allow an escalation of privilege. System software adversary with...Show more |
1Phoenixcontact 69Fl Nat 2008 Firmware Fl Nat 2208 FirmwareFl Nat 2304 2gc 2sfp Firmware+66 moreJun 17, 2026 Dec 9, 2025 N/A· v4 6.8 MEDIUM· v3 N/A· v2 An attacker can use an undocumented UART port on the PCB as a side-channel to get root access e.g. with the credentials obtained from CVE-2025-41692. |
Panasonic IR Control Hub (IR Blaster) versions 1.17 and earlier may allow an attacker with physical access to load unauthorized firmware onto the device. |
A serial interface can be accessed with physical access to the PCB of Wattsense Bridge devices. After connecting to the interface, access to the bootloader is possible, as well as a Linux login prompt. The bootloader acc...Show more |
The device directly executes .patch firmware upgrade files on a USB stick without any prior authentication in the admin interface. This leads to an unauthenticated code execution via the firmware upgrade function. |
IBM FlashSystem 5300 USB ports may be usable even if the port has been disabled by the administrator. A user with physical access to the system could use the USB port to cause loss of access to data. IBM X-Force ID: 29...Show more |
The FACSChorus workstation does not prevent physical access to its PCI express (PCIe) slots, which could allow a threat actor to insert a PCI card designed for memory capture. A threat actor can then isolate sensitive in...Show more |
The FACSChorus workstation operating system does not restrict what devices can interact with its USB ports. If exploited, a threat actor with physical access to the workstation could gain access to system information and...Show more |
1Bd 7Bodyguard 121 Twins Firmware Bodyguard 323 Colorvision FirmwareBodyguard 999 603 Firmware+4 moreJun 17, 2026 Dec 5, 2022 N/A· v4 5.3 MEDIUM· v3 N/A· v2 The BD BodyGuard™ infusion pumps specified allow for access through the RS-232 (serial) port interface. If exploited, threat actors with physical access, specialized equipment and knowledge may be able to configure or di...Show more |
1Binatoneglobal 21Cn28 Firmware Cn40 FirmwareCn50 Firmware+18 moreJun 17, 2026 Nov 12, 2021 N/A· v4 6.8 MEDIUM· v3 4.6 MEDIUM· v2 An exposed debug interface was reported in some Motorola-branded Binatone Hubble Cameras that could allow an attacker with physical access unauthorized access to the device. |