CVE-2021-36201
5.3
Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Exploitability: 3.9 / Impact: 1.4
Source: NVD
Description
Under certain circumstances a CCURE Portal user could enumerate user accounts in CCURE 9000 version 2.90 and prior versions.
Affected (1)
Products: Johnsoncontrols: C Cure 9000 Firmware
Configuration A
| Vulnerable Software | Affected Versions |
|---|---|
| Up to 2.90 |
| Running on/with | Platform Versions |
|---|---|
Johnsoncontrols C Cure 9000 | All versions |
Related CWEs
CWE-203
Observable Discrepancy
The product behaves differently or sends different responses under different circumstances in a way that is observable to an unauthorized actor, which exposes security-relevant information about the state of the product, such as whether a particular operation was successful or not.
CWE-204
Observable Response Discrepancy
The product provides different responses to incoming requests in a way that reveals internal state information to an unauthorized actor outside of the intended control sphere.
References (4)
Source: productsecurity@jci.com
Third Party AdvisoryUS Government Resource
Source: productsecurity@jci.com
Vendor Advisory
Source: af854a3a-2127-422b-91ae-364da2661108
Third Party AdvisoryUS Government Resource
Source: af854a3a-2127-422b-91ae-364da2661108
Vendor Advisory
Timeline
No history available yet.