← Back

Johnsoncontrols

johnsoncontrols

68 CVEs • 113 products

Products (113)

Click to collapse
Toggle
Metsys
metsys
Videoedge
videoedge
Bcpro
bcpro
Entrapass
entrapass
Nie55 Firmware
nie55_firmware
Nie59 Firmware
nie59_firmware
Nae85 Firmware
nae85_firmware
Nie85 Firmware
nie85_firmware
C Cure Web
c-cure_web
Victor Web
victor_web
Metasys
metasys
Cevas
cevas
Nxe8500
nxe8500
Nae55
nae55
Nie55
nie55
Nie59
nie59
Nae85
nae85
Nie85
nie85
Ul 864 Uukl
ul_864_uukl
C Cure 9000
c-cure_9000
F4 Snc
f4-snc
Ac2000
ac2000
Istar Ultra
istar_ultra
Edge G2
edge_g2
Iq Wifi 6
iq_wifi_6

CVEs (68)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
6.9 MEDIUM· v4
9.8 CRITICAL· v3
N/A· v2
Hardcoded Email Credentials Saved as Plaintext in Firmware (CWE-256: Plaintext Storage of a Password) vulnerability in Frick Controls Quantum HD version 10.22 and prior lead to unauthorized access, exposure of sensitive...Show more
Hardcoded Email Credentials Saved as Plaintext in Firmware (CWE-256: Plaintext Storage of a Password) vulnerability in Frick Controls Quantum HD version 10.22 and prior lead to unauthorized access, exposure of sensitive information, and potential misuse or system compromise This issue affects Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
8.7 HIGH· v4
9.8 CRITICAL· v3
N/A· v2
Unauthenticated Remote Code Execution and Information Disclosure due to Local File Inclusion (LFI) vulnerability in Johnson Controls Frick Controls Quantum HD allow an unauthenticated attacker to execute arbitrary code o...Show more
Unauthenticated Remote Code Execution and Information Disclosure due to Local File Inclusion (LFI) vulnerability in Johnson Controls Frick Controls Quantum HD allow an unauthenticated attacker to execute arbitrary code on the affected device, leading to full system compromise. This issue affects Frick Controls Quantum HD: Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
8.8 HIGH· v4
9.8 CRITICAL· v3
N/A· v2
Unauthenticated Remote Code Execution i.e Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in c...Show more
Unauthenticated Remote Code Execution i.e Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in certain parameters may permit unexpected actions, which could impact the security of the device before authentication occurs.This issue affects Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
8.8 HIGH· v4
9.8 CRITICAL· v3
N/A· v2
Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in certain parameters may permit unexpected ac...Show more
Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in certain parameters may permit unexpected actions, which could impact the security of the device before authentication occurs.This issue affects Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
8.8 HIGH· v4
9.8 CRITICAL· v3
N/A· v2
Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in certain parameters may permit unexpected ac...Show more
Improper Control of Generation of Code ('Code Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows Code Injection. Insufficient validation of input in certain parameters may permit unexpected actions, which could impact the security of the device before authentication occurs.This issue affects Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Frick Controls Quantum Hd Firmware
Jun 17, 2026
Feb 27, 2026
8.8 HIGH· v4
9.8 CRITICAL· v3
N/A· v2
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows OS Command Injection. Insufficient validation of input in cert...Show more
Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability in Johnson Controls Frick Controls Quantum HD allows OS Command Injection. Insufficient validation of input in certain parameters may permit unexpected actions, which could impact the security of the device before authentication occurs.This issue affects Frick Controls Quantum HD version 10.22 and prior.Show less
1Johnsoncontrols
1Exacqvision Web Service
Jun 17, 2026
Aug 1, 2024
N/A· v4
5.7 MEDIUM· v3
N/A· v2
Under certain circumstances the exacqVision Web Service can expose authentication token details within communications.
1Johnsoncontrols
1Exacqvision Server
Jun 17, 2026
Aug 1, 2024
N/A· v4
7.3 HIGH· v3
N/A· v2
Under certain circumstances the exacqVision Server will not properly validate TLS certificates provided by connected devices.
1Johnsoncontrols
1Exacqvision Web Service
Jun 17, 2026
Aug 1, 2024
N/A· v4
8.1 HIGH· v3
N/A· v2
Under certain circumstances the ExacqVision Web Services does not provide sufficient protection from untrusted domains.
1Johnsoncontrols
2Exacqvision Client
Exacqvision Server
Jun 17, 2026
Aug 1, 2024
9.0 CRITICAL· v4
7.5 HIGH· v3
N/A· v2
Under certain circumstances the communication between exacqVision Client and exacqVision Server will use insufficient key length and exchange
1Johnsoncontrols
1Exacqvision Web Service
Jun 17, 2026
Aug 1, 2024
N/A· v4
8.1 HIGH· v3
N/A· v2
Under certain circumstances exacqVision Web Services will not enforce secure web communications (HTTPS)
1Johnsoncontrols
1Exacqvision Web Service
Jun 17, 2026
Aug 1, 2024
N/A· v4
8.8 HIGH· v3
N/A· v2
Under certain circumstances the exacqVision Web Services may be susceptible to Cross-Site Request Forgery (CSRF)
1Johnsoncontrols
1Software House C Cure 9000 Siteserver
Jun 17, 2026
Jun 6, 2024
8.5 HIGH· v4
4.2 MEDIUM· v3
N/A· v2
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interf...Show more
Under certain circumstances the Microsoft® Internet Information Server (IIS) used to host the C•CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C•CURE 9000 or prior versionsShow less
1Johnsoncontrols
2Qolsys Iq4 Hub Firmware
Qolsys Iq Panel 4 Firmware
Jun 17, 2026
Feb 8, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Under certain circumstances IQ Panel4 and IQ4 Hub panel software prior to version 4.4.2 could allow unauthorized access to settings.
1Johnsoncontrols
1Iosmart Gen 1 Firmware
Jun 17, 2026
Dec 14, 2023
N/A· v4
5.3 MEDIUM· v3
N/A· v2
An attacker with physical access to the Kantech Gen1 ioSmart card reader with firmware version prior to 1.07.02 in certain circumstances can recover the reader's communication memory between the card and reader.
1Johnsoncontrols
10F4 Snc Firmware
Nae55 FirmwareSnc16120 04 Firmware+7 more
Jun 17, 2026
Dec 7, 2023
N/A· v4
7.5 HIGH· v3
N/A· v2
Under certain circumstances, invalid authentication credentials could be sent to the login endpoint of Johnson Controls Metasys NAE55, SNE, and SNC engines prior to versions 11.0.6 and 12.0.4 and Facility Explorer F4...Show more
Under certain circumstances, invalid authentication credentials could be sent to the login endpoint of Johnson Controls Metasys NAE55, SNE, and SNC engines prior to versions 11.0.6 and 12.0.4 and Facility Explorer F4-SNC engines prior to versions 11.0.6 and 12.0.4 to cause denial-of-service. Show less
1Johnsoncontrols
6Quantum Hd Unity Acuair Firmware
Quantum Hd Unity Compressor FirmwareQuantum Hd Unity Condenser/vessel Firmware+3 more
Jun 17, 2026
Nov 10, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
An unauthorized user could access debug features in Quantum HD Unity products that were accidentally exposed.
1Johnsoncontrols
1Videoedge
Jun 17, 2026
Aug 3, 2023
N/A· v4
5.5 MEDIUM· v3
N/A· v2
A local user could edit the VideoEdge configuration file and interfere with VideoEdge operation.
1Johnsoncontrols
1Iq Wifi 6 Firmware
Jun 17, 2026
Jul 25, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
An unauthorized user could gain account access to IQ Wifi 6 versions prior to 2.0.2 by conducting a brute force authentication attack.
1Johnsoncontrols
4Edge G2 Firmware
Istar Ultra FirmwareIstar Ultra G2 Firmware+1 more
Jun 17, 2026
Jul 11, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
An unauthenticated user could log into iSTAR Ultra, iSTAR Ultra LT, iSTAR Ultra G2, and iSTAR Edge G2 with administrator rights.