Improper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model v...Show moreImproper Restriction of Rendered UI Layers or Frames vulnerability in Mitsubishi Electric Corporation GOT2000 Series GT27 model versions 01.14.000 to 01.47.000, Mitsubishi Electric Corporation GOT2000 Series GT25 model versions 01.14.000 to 01.47.000 and Mitsubishi Electric Corporation GT SoftGOT2000 versions 1.265B to 1.285X allows a remote unauthenticated attacker to lead legitimate users to perform unintended operations through clickjacking.Show less |
Active Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authen...Show moreActive Debug Code vulnerability in robot controller of Mitsubishi Electric Corporation industrial robot MELFA SD/SQ Series and MELFA F-Series allows a remote unauthenticated attacker to gain unauthorized access by authentication bypass through an unauthorized telnet login. As for the affected model names, controller types and firmware versions, see the Mitsubishi Electric's advisory which is listed in [References] section.Show less |
Predictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versi...Show morePredictable Seed in Pseudo-Random Number Generator (PRNG) vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5U-xMy/z (x=32,64,80, y=T,R, z=ES,DS,ESS,DSS) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 17X**** or later, and versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-xMy/z (x=32,64,96, y=T, z=D,DSS)) with serial number 179**** and prior, and versions 1.074 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MT/DSS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/z (x=24,40,60, y=T,R, z=ES,ESS) versions 1.042 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UJ-xMy/ES-A (x=24,40,60, y=T,R) versions 1.043 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5S-xMy/z (x=30,40,60,80, y=T,R, z=ES,ESS) versions 1.003 and prior, Mitsubishi Electric Corporation MELSEC iQ-F Series FX5UC-32MR/DS-TS versions 1.280 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU versions 33 and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU versions 66 and prior allows a remote unauthenticated attacker to access the Web server function by guessing the random numbers used for authentication from several used random numbers.Show less |
Improper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network...Show moreImproper Input Validation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series RJ71EN71 Firmware version "65" and prior and Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120ENCPU Network Part Firmware version "65" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition by sending specially crafted packets. A system reset is required for recovery.Show less |
Insufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthent...Show moreInsufficiently Protected Credentials vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could access to MELSEC safety CPU modules illgally.Show less |
Cleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote...Show moreCleartext Storage of Sensitive Information in Memory vulnerability in Mitsubishi Electric Corporation GX Works3 versions 1.015R and later, GX Works2 all versions and GX Developer versions 8.40S and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users could obtain information about the project file for MELSEC safety CPU modules or project file for MELSEC Q/FX/L series with security setting.Show less |
Use of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety...Show moreUse of Hard-coded Password vulnerability in Mitsubishi Electric Corporation GX Works3 versions from 1.015R to 1.095Z allows a remote unauthenticated attacker to obtain information about the project file for MELSEC safety CPU modules.Show less |
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote una...Show moreUse of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z, and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.065T allows a remote unauthenticated attacker to disclose or tamper with sensitive information. As a result, unauthenticated attackers may obtain information about project files illegally.Show less |
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related...Show moreUse of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U, and MT Works2 versions from 1.100E to 1.200J allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.Show less |
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated a...Show moreUse of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally.Show less |
Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated a...Show moreUse of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally.Show less |
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remo...Show moreCleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.Show less |
Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allow...Show moreUse of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C, and MT Works2 versions from 1.100E to 1.200J allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally.Show less |
Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote un...Show moreCleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module.Show less |
Improper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and...Show moreImproper Input Validation vulnerability in Mitsubishi Electric GOT2000 Series GT27 model FTP server versions 01.39.000 and prior, Mitsubishi Electric GOT2000 Series GT25 model FTP server versions 01.39.000 and prior and Mitsubishi Electric GOT2000 Series GT23 model FTP server versions 01.39.000 and prior allows a remote authenticated attacker to cause a Denial of Service condition by sending specially crafted command.Show less |
Cross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Ric...Show moreCross-site scripting vulnerability in Mitsubishi Electric consumer electronics products (Air Conditioning, Wi-Fi Interface, Refrigerator, HEMS adapter, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch and Air Purifier) allows a remote unauthenticated attacker to execute an malicious script on a user's browser to disclose information, etc. The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability. As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
Show less |
Cleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS a...Show moreCleartext Transmission of Sensitive Information vulnerability due to the use of Basic Authentication for HTTP connections in Mitsubishi Electric consumer electronics products (PHOTOVOLTAIC COLOR MONITOR ECO-GUIDE, HEMS adapter, Wi-Fi Interface, Air Conditioning, Induction hob, Mitsubishi Electric HEMS Energy Measurement Unit, Refrigerator, Remote control with Wi-Fi Interface, BATHROOM THERMO VENTILATOR, Rice cooker, Mitsubishi Electric HEMS control adapter, Energy Recovery Ventilator, Smart Switch, Ventilating Fan, Range hood fan, Energy Measurement Unit and Air Purifier) allows a remote unauthenticated attacker to disclose information in the products or cause a denial of service (DoS) condition as a result by sniffing credential information (username and password).
The wide range of models/versions of Mitsubishi Electric consumer electronics products are affected by this vulnerability.
As for the affected product models/versions, see the Mitsubishi Electric's advisory which is listed in [References] section.
Show less |
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS S...Show moreDeserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.Show less |
Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 1...Show moreOut-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.Show less |
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS S...Show moreDeserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.Show less |