← Back

Mitsubishielectric

mitsubishielectric

161 CVEs • 1,961 products

Products (1,961)

Click to collapse
Toggle
Gx Works3
gx_works3
Gx Works2
gx_works2
Ezsocket
ezsocket
Rt Toolbox3
rt_toolbox3
Mx Component
mx_component
Gx Logviewer
gx_logviewer
Mc Works64
mc_works64
Data Transfer
data_transfer
Gx Developer
gx_developer
Coreos
coreos
Genesis64
genesis64
Gt Got1000
gt_got1000
Gt Got2000
gt_got2000
Iq Works
iq_works
Rt Visualbox
rt_visualbox
Mt Works2
mt_works2
Gt Designer3
gt_designer3
Melfa Works
melfa-works
Rt Toolbox2
rt_toolbox2
Mc Works32
mc_works32
Mc Works
mc_works

CVEs (161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Mitsubishielectric
1Iu1 1m20 D Firmware
Nov 21, 2024
Mar 16, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions...Show more
TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier does not properly manage sessions, which allows remote attackers to stop the network functions or execute malware via a specially crafted packet.Show less
1Mitsubishielectric
1Iu1 1m20 D Firmware
Nov 21, 2024
Mar 16, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute...Show more
Buffer error vulnerability in TCP function included in the firmware of Mitsubishi Electric MELQIC IU1 series IU1-1M20-D firmware version 1.0.7 and earlier allows remote attackers to stop the network functions or execute malware via a specially crafted packet.Show less
1Mitsubishielectric
5Mi5122 Vw Firmware
Q24dhccpu V FirmwareQ24dhccpu Vg Firmware+2 more
Nov 21, 2024
Feb 17, 2020
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSE...Show more
Mitsubishi Electric MELSEC C Controller Module and MELIPC Series MI5000 MELSEC-Q Series C Controller Module(Q24DHCCPU-V, Q24DHCCPU-VG User Ethernet port (CH1, CH2): First 5 digits of serial number 21121 or before), MELSEC iQ-R Series C Controller Module / C Intelligent Function Module(R12CCPU-V Ethernet port (CH1, CH2): First 2 digits of serial number 11 or before, and RD55UP06-V Ethernet port: First 2 digits of serial number 08 or before), and MELIPC Series MI5000(MI5122-VW Ethernet port (CH1): First 2 digits of serial number 03 or before, or the firmware version 03 or before) allow remote attackers to cause a denial of service and/or malware being executed via unspecified vectors.Show less
1Mitsubishielectric
10L02/06/26cpu Cm Firmware
L02/06/26cpu P FirmwareL02/06/26cpu Firmware+7 more
Nov 21, 2024
Nov 13, 2019
N/A· v4
5.9 MEDIUM· v3
4.3 MEDIUM· v2
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and pr...Show more
In Mitsubishi Electric MELSEC-Q Series Q03/04/06/13/26UDVCPU: serial number 21081 and prior, Q04/06/13/26UDPVCPU: serial number 21081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 21081 and prior, MELSEC-L Series L02/06/26CPU, L26CPU-BT: serial number 21101 and prior, L02/06/26CPU-P, L26CPU-PBT: serial number 21101 and prior, and L02/06/26CPU-CM, L26CPU-BT-CM: serial number 21101 and prior, a remote attacker can cause the FTP service to enter a denial-of-service condition dependent on the timing at which a remote attacker connects to the FTP server on the above CPU modules.Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbit...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote OS Command Injection vulnerability allows an attacker to execute arbitrary commands on the RTU due to the passing of unsafe user supplied data to the RTU's system shell. Functionality in mobile.php provides users with the ability to ping sites or IP addresses via Mobile Connection Test. When the Mobile Connection Test is submitted, action.php is called to execute the test. An attacker can use a shell command separator (;) in the host variable to execute operating system commands upon submitting the test data.Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Undocumented hard-coded user passwords for root, ineaadmin, mitsadmin, and maint could allow an attacker to gain unauthorised access to the RTU. (Also, the accounts ineaadmin and mitsadmin are able to escalate privileges to root without supplying a password due to insecure entries in /etc/sudoers on the RTU.)Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
9.8 CRITICAL· v3
5.0 MEDIUM· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Stored cleartext passwords could allow an unauthenticated attacker to obtain configured username and password combinations on the RTU due to the weak credentials management on the RTU. An unauthenticated user can obtain the exposed password credentials to gain access to the following services: DDNS service, Mobile Network Provider, and OpenVPN service.Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
5.4 MEDIUM· v3
3.5 LOW· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page.Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download th...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. An unauthenticated remote configuration download vulnerability allows an attacker to download the smartRTU's configuration file (which contains data such as usernames, passwords, and other sensitive RTU data).Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. Hard-coded SSH keys allow an attacker to gain unauthorised access or disclose encrypted data on the RTU due to the keys not being regenerated on initial installation or with firmware updates. In other words, these devices use private-key values in /etc/ssh/ssh_host_rsa_key, /etc/ssh/ssh_host_ecdsa_key, and /etc/ssh/ssh_host_dsa_key files that are publicly available from the vendor web sites.Show less
2Inea
Mitsubishielectric
2Me Rtu Firmware
Smartrtu Firmware
Nov 21, 2024
Oct 28, 2019
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an...Show more
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A world-readable /usr/smartrtu/init/settings.xml configuration file on the file system allows an attacker to read sensitive configuration settings such as usernames, passwords, and other sensitive RTU data due to insecure permission assignment.Show less
1Mitsubishielectric
1Electric Fr Configurator2 Firmware
Nov 21, 2024
Jul 26, 2019
N/A· v4
5.5 MEDIUM· v3
4.3 MEDIUM· v2
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user...Show more
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability is triggered when input passed to the XML parser is not sanitized while parsing the XML project and/or template file (.frc2). Once a user opens the file, the attacker could read arbitrary files.Show less
1Mitsubishielectric
1Electric Fr Configurator2
Nov 21, 2024
Jul 26, 2019
N/A· v4
5.5 MEDIUM· v3
7.1 HIGH· v2
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhausti...Show more
Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted.Show less
1Mitsubishielectric
1Qj71e71 100 Firmware
Nov 21, 2024
May 23, 2019
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and...Show more
In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition.Show less
1Mitsubishielectric
18Q03udecpu Firmware
Q03udvcpu FirmwareQ04udehcpu Firmware+15 more
Jun 26, 2025
Feb 5, 2019
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attac...Show more
Mitsubishi Electric Q03/04/06/13/26UDVCPU: serial number 20081 and prior, Q04/06/13/26UDPVCPU: serial number 20081 and prior, and Q03UDECPU, Q04/06/10/13/20/26/50/100UDEHCPU: serial number 20101 and prior. A remote attacker can send specific bytes over Port 5007 that will result in an Ethernet stack crash and disruption to USB communication.Show less
1Mitsubishielectric
1E Designer
Nov 21, 2024
Apr 17, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and syst...Show more
Mitsubishi E-Designer, Version 7.52 Build 344 contains six code sections which may be exploited to overwrite the stack. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.Show less
1Mitsubishielectric
1E Designer
Nov 21, 2024
Apr 17, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and syst...Show more
Mitsubishi E-Designer, Version 7.52 Build 344 contains five code sections which may be exploited to overwrite the heap. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.Show less
1Mitsubishielectric
1E Designer
Nov 21, 2024
Apr 17, 2018
N/A· v4
9.8 CRITICAL· v3
10.0 HIGH· v2
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data...Show more
Mitsubishi E-Designer, Version 7.52 Build 344 contains two code sections which may be exploited to allow an attacker to overwrite arbitrary memory locations. This can result in arbitrary code execution, compromised data integrity, denial of service, and system crash.Show less
1Mitsubishielectric
3Qj71e71 100 Firmware
Qj71e71 B2 FirmwareQj71e71 B5 Firmware
May 13, 2026
Feb 13, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are trans...Show more
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.Show less
1Mitsubishielectric
3Qj71e71 100 Firmware
Qj71e71 B2 FirmwareQj71e71 B5 Firmware
May 13, 2026
Feb 13, 2017
N/A· v4
8.6 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface modu...Show more
An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. The affected Ethernet interface module is connected to a MELSEC-Q PLC, which may allow a remote attacker to connect to the PLC via Port 5002/TCP and cause a denial of service, requiring the PLC to be reset to resume operation. This is caused by an Unrestricted Externally Accessible Lock.Show less