← Back

Mitsubishielectric

mitsubishielectric

161 CVEs • 1,961 products

Products (1,961)

Click to collapse
Toggle
Gx Works3
gx_works3
Gx Works2
gx_works2
Ezsocket
ezsocket
Rt Toolbox3
rt_toolbox3
Mx Component
mx_component
Gx Logviewer
gx_logviewer
Mc Works64
mc_works64
Data Transfer
data_transfer
Gx Developer
gx_developer
Coreos
coreos
Genesis64
genesis64
Gt Got1000
gt_got1000
Gt Got2000
gt_got2000
Iq Works
iq_works
Rt Visualbox
rt_visualbox
Mt Works2
mt_works2
Gt Designer3
gt_designer3
Melfa Works
melfa-works
Rt Toolbox2
rt_toolbox2
Mc Works32
mc_works32
Mc Works
mc_works

CVEs (161)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Mitsubishielectric
1Melsec Iq F Fx5 Enet/ip Firmware
Apr 30, 2026
Mar 3, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) c...Show more
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP all versions allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.Show less
1Mitsubishielectric
1Melsec Iq F Fx5 Eip Firmware
Apr 30, 2026
Mar 3, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service...Show more
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.Show less
1Mitsubishielectric
2Melsec Iq F Fx5 Eip Firmware
Melsec Iq F Fx5 Enet/ip Firmware
May 4, 2026
Mar 3, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC...Show more
Always-Incorrect Control Flow Implementation vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-ENET/IP Ethernet Module FX5-ENET/IP versions 1.106 and prior and Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery.Show less
2Iconics
Mitsubishielectric
2Genesis64
Mc Works64
Jan 9, 2026
Oct 22, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versio...Show more
Incorrect Default Permissions vulnerability in GenBroker32, which is included in the installers for Mitsubishi Electric GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97.3 and prior, Mitsubishi Electric ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97.3 and prior, Mitsubishi Electric GENESIS32 versions 9.70.300.23 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.70.300.23 and prior, and Mitsubishi Electric MC Works64 all versions allows a local authenticated attacker to disclose or tamper with confidential information and data contained in the products, or cause a denial of service (DoS) condition on the products, by accessing a folder with incorrect permissions, when GenBroker32 is installed on the same PC as GENESIS64, ICONICS Suite, MC Works64, or GENESIS32.Show less
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 21, 2025
Jul 2, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Improper privilege management in Jungo WinDriver 6.0.0 through 16.1.0 allows local attackers to escalate privileges and execute arbitrary code.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges and execute arbitrary code.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 14, 2025
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.7.0 allows local attackers to cause a Windows blue screen error.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Improper privilege management in Jungo WinDriver before 12.2.0 allows local attackers to escalate privileges and execute arbitrary code.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Improper privilege management in Jungo WinDriver before 12.5.1 allows local attackers to escalate privileges, execute arbitrary code, or cause a Denial of Service (DoS).
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 13, 2025
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.5.1 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 18, 2025
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.6.0 allows local attackers to cause a Windows blue screen error.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 13, 2025
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Out-of-Bounds Write vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error and Denial of Service (DoS).
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Nov 21, 2024
Jul 2, 2024
N/A· v4
5.5 MEDIUM· v3
N/A· v2
Denial of Service (DoS) vulnerability in Jungo WinDriver before 12.1.0 allows local attackers to cause a Windows blue screen error.
2Jungo
Mitsubishielectric
35Cpu Module Logging Configuration Tool
Cw ConfiguratorData Transfer+32 more
Mar 13, 2025
Jul 2, 2024
N/A· v4
7.8 HIGH· v3
N/A· v2
Improper privilege management in Jungo WinDriver before 12.1.0 allows local attackers to escalate privileges and execute arbitrary code.
1Mitsubishielectric
8R08psfcpu Firmware
R08sfcpu FirmwareR120psfcpu Firmware+5 more
Nov 21, 2024
Feb 13, 2024
N/A· v4
6.5 MEDIUM· v3
N/A· v2
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allow...Show more
Incorrect Privilege Assignment vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series Safety CPU R08/16/32/120SFCPU all versions and MELSEC iQ-R Series SIL2 Process CPU R08/16/32/120PSFCPU all versions allows a remote authenticated attacker who has logged into the product as a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than the attacker by sending a specially crafted packet.Show less
1Mitsubishielectric
10Ezsocket
Fr Configurator2Got1000+7 more
Sep 19, 2025
Jan 30, 2024
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior,...Show more
Use of Externally-Controlled Input to Select Classes or Code ('Unsafe Reflection') vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to execute a malicious code by RPC with a path to a malicious library while connected to the products.Show less
1Mitsubishielectric
10Ezsocket
Fr Configurator2Got1000+7 more
Sep 19, 2025
Jan 30, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versio...Show more
Missing Authentication for Critical Function vulnerability in Mitsubishi Electric Corporation EZSocket versions 3.0 to 5.92, GT Designer3 Version1(GOT1000) versions 1.325P and prior, GT Designer3 Version1(GOT2000) versions 1.320J and prior, GX Works2 versions 1.11M to 1.626C, GX Works3 versions 1.106L and prior, MELSOFT Navigator versions 1.04E to 2.102G, MT Works2 versions 1.190Y and prior, MX Component versions 4.00A to 5.007H and MX OPC Server DA/UA all versions allows a remote unauthenticated attacker to bypass authentication by sending specially crafted packets and connect to the products illegally.Show less
1Mitsubishielectric
1Melsec Ws0 Geth00200 Firmware
Nov 21, 2024
Jan 30, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-repl...Show more
Authentication Bypass by Capture-replay vulnerability in Mitsubishi Electric Corporation MELSEC WS Series WS0-GETH00200 all serial numbers allows a remote unauthenticated attacker to bypass authentication by capture-replay attack and illegally login to the affected module. As a result, the remote attacker who has logged in illegally may be able to disclose or tamper with the programs and parameters in the modules.Show less