← Back

Fatek

fatek

44 CVEs • 14 products

Products (14)

Click to collapse
Toggle

CVEs (44)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Fatek
4Ethernet Module Configuration Tool Cbe Firmware
Ethernet Module Configuration Tool Cbeh FirmwareEthernet Module Configuration Tool Cm25e Firmware+1 more
May 13, 2026
Mar 16, 2017
N/A· v4
9.8 CRITICAL· v3
9.0 HIGH· v2
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 B...Show more
An issue was discovered in Fatek Automation PLC Ethernet Module. The affected Ether_cfg software configuration tool runs on the following Fatek PLCs: CBEH versions prior to V3.6 Build 170215, CBE versions prior to V3.6 Build 170215, CM55E versions prior to V3.6 Build 170215, and CM25E versions prior to V3.6 Build 170215. A stack-based buffer overflow vulnerability has been identified, which may allow remote code execution or crash the affected device.Show less
1Fatek
1Plc Winproladder Firmware
May 13, 2026
Feb 13, 2017
N/A· v4
8.0 HIGH· v3
6.0 MEDIUM· v2
An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack...Show more
An issue was discovered in Fatek Automation PLC WinProladder Version 3.11 Build 14701. A stack-based buffer overflow vulnerability exists when the software application connects to a malicious server, resulting in a stack buffer overflow. This causes an exploitable Structured Exception Handler (SEH) overwrite condition that may allow remote code execution.Show less
1Fatek
2Automation Fv Designer
Automation Pm Designer
May 13, 2026
Feb 13, 2017
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cau...Show more
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. By sending additional valid packets, an attacker could trigger a stack-based buffer overflow and cause a crash. Also, a malicious attacker can trigger a remote buffer overflow on the Fatek Communication Server.Show less
1Fatek
2Automation Fv Designer
Automation Pm Designer
May 13, 2026
Feb 13, 2017
N/A· v4
8.8 HIGH· v3
6.8 MEDIUM· v2
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. Sending additional valid packets could allow the attacker to cause a crash or to execute arbitrary c...Show more
An issue was discovered in Fatek Automation PM Designer V3 Version 2.1.2.2, and Automation FV Designer Version 1.2.8.0. Sending additional valid packets could allow the attacker to cause a crash or to execute arbitrary code, because of Improper Restriction of Operations within the Bounds of a Memory Buffer.Show less