← Back

Biotronik

biotronik

5 CVEs • 4 products

Products (4)

Click to collapse
Toggle

CVEs (5)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Biotronik
2Cardiomessenger Ii S Gsm Firmware
Cardiomessenger Ii S T Line Firmware
Nov 21, 2024
Jun 29, 2020
N/A· v4
4.6 MEDIUM· v3
2.1 LOW· v2
BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for net...Show more
BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit.Show less
1Biotronik
2Cardiomessenger Ii S Gsm Firmware
Cardiomessenger Ii S T Line Firmware
Nov 21, 2024
Jun 29, 2020
N/A· v4
4.6 MEDIUM· v3
2.1 LOW· v2
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number...Show more
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with.Show less
1Biotronik
2Cardiomessenger Ii S Gsm Firmware
Cardiomessenger Ii S T Line Firmware
Nov 21, 2024
Jun 29, 2020
N/A· v4
4.3 MEDIUM· v3
3.3 LOW· v2
BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to...Show more
BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure.Show less
1Biotronik
2Cardiomessenger Ii S Gsm Firmware
Cardiomessenger Ii S T Line Firmware
Nov 21, 2024
Jun 29, 2020
N/A· v4
4.3 MEDIUM· v3
3.3 LOW· v2
BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to...Show more
BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure.Show less
1Biotronik
2Cardiomessenger Ii S Gsm Firmware
Cardiomessenger Ii S T Line Firmware
Nov 21, 2024
Jun 29, 2020
N/A· v4
4.3 MEDIUM· v3
3.3 LOW· v2
BIOTRONIK CardioMessenger II, The affected products do not properly enforce mutual authentication with the BIOTRONIK Remote Communication infrastructure.