← Back

Apc

apc

14 CVEs • 11 products

Products (11)

Click to collapse
Toggle
Powerchute
powerchute
Apcupsd
apcupsd
Ap9606
ap9606
Oas
oas
Ap7932 B2
ap7932_b2
Aos
aos

CVEs (14)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Apc
1Powerchute
Nov 21, 2024
Aug 31, 2020
N/A· v4
8.8 HIGH· v3
6.5 MEDIUM· v2
Improper Input Validation vulnerability exists in PowerChute Business Edition (software V9.0.x and earlier) which could cause remote code execution when a script is executed during a shutdown event.
1Apc
1Powerchute
Apr 29, 2026
Dec 7, 2011
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Cross-site scripting (XSS) vulnerability in Schneider Electric PowerChute Business Edition before 8.5 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
1Apc
2Network Management Card
Switched Rack Pdu
Apr 23, 2026
Dec 28, 2009
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote att...Show more
Multiple cross-site scripting (XSS) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to inject arbitrary web script or HTML via unspecified vectors. NOTE: the login_username vector for Forms/login1 is already covered by CVE-2009-4406.Show less
1Apc
2Network Management Card
Switched Rack Pdu
Apr 23, 2026
Dec 28, 2009
N/A· v4
N/A· v3
6.8 MEDIUM· v2
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow rem...Show more
Multiple cross-site request forgery (CSRF) vulnerabilities on the Network Management Card (NMC) on American Power Conversion (APC) Switched Rack PDU (aka Rack Mount Power Distribution) devices and other devices allow remote attackers to hijack the authentication of (1) administrator or (2) device users for requests that create new administrative users or have unspecified other impact.Show less
1Apc
2Ap7932 B2
Ap7932 B2 Firmware
Apr 23, 2026
Dec 23, 2009
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to i...Show more
Cross-site scripting (XSS) vulnerability in Forms/login1 in American Power Conversion (APC) Switched Rack PDU AP7932 B2, running rpdu 3.3.3 or 3.7.0 on AOS 3.3.4, and possibly other versions, allows remote attackers to inject arbitrary web script or HTML via the login_username parameter.Show less
1Apc
2Oas
Switched Rack Pdu Firmware
Apr 23, 2026
Dec 4, 2007
N/A· v4
N/A· v3
7.1 HIGH· v2
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login a...Show more
The American Power Conversion (APC) AP7932 0u 30amp Switched Rack Power Distribution Unit (PDU), with rpdu 3.5.5 and aos 3.5.6, allows remote attackers to bypass authentication and obtain login access by making a login attempt while a different client is logged in, and then resubmitting the login attempt once the other client exits.Show less
1Apc
1Powerchute Network Shutdown
Apr 16, 2026
Dec 17, 2005
N/A· v4
N/A· v3
5.0 MEDIUM· v2
The web interface for American Power Conversion (APC) PowerChute Network Shutdown performs all communication in cleartext (base64-encoded), which allows remote attackers to sniff authentication credentials.
1Apc
1Powerchute
Apr 16, 2026
Dec 31, 2004
N/A· v4
N/A· v3
5.0 MEDIUM· v2
Unknown vulnerability in APC PowerChute Business Edition 6.0 through 7.0.1 allows remote attackers to cause a denial of service via unknown attack vectors.
1Apc
1Ap9606
Apr 16, 2026
Nov 23, 2004
N/A· v4
N/A· v3
10.0 HIGH· v2
American Power Conversion (APC) Web/SNMP Management SmartSlot Card 3.0 through 3.0.3 and 3.21 are shipped with a default password of TENmanUFactOryPOWER, which allows remote attackers to gain unauthorized access.
1Apc
1Apcupsd
Apr 16, 2026
Mar 3, 2003
N/A· v4
N/A· v3
7.2 HIGH· v2
Multiple buffer overflows in apcupsd before 3.8.6, and 3.10.x before 3.10.5, may allow attackers to cause a denial of service or execute arbitrary code, related to usage of the vsprintf function.
1Apc
1Powerchute
Apr 16, 2026
Dec 31, 2002
N/A· v4
N/A· v3
5.0 MEDIUM· v2
PowerChute plus 5.0.2 creates a "Pwrchute" directory during installation that is shared and world writeable, which could allow remote attackers to modify or create files in that directory.
1Apc
1Ap9606
Apr 16, 2026
Aug 22, 2001
N/A· v4
N/A· v3
5.0 MEDIUM· v2
APC Web/SNMP Management Card prior to Firmware 310 only supports one telnet connection, which allows a remote attacker to create a denial of service via repeated failed logon attempts which temporarily locks the card.
1Apc
1Apcupsd
Apr 16, 2026
Feb 16, 2001
N/A· v4
N/A· v3
2.1 LOW· v2
APC UPS daemon, apcupsd, saves its process ID in a world-writable file, which allows local users to kill an arbitrary process by specifying the target process ID in the apcupsd.pid file.
1Apc
1Powerchute
Apr 16, 2026
Dec 31, 2000
N/A· v4
N/A· v3
9.0 HIGH· v2
The HTTP service in American Power Conversion (APC) PowerChute uses a default username and password, which allows remote attackers to gain system access.