CVEs (38)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
4Belden SiemensSonicwall+1 more119410 Power Meter Firmware 9810 Power Meter FirmwareGarrettcom Magnum Dx940e Firmware+8 moreNov 21, 2024 Aug 9, 2019 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 Wind River VxWorks 6.6, 6.7, 6.8, 6.9 and vx7 has an array index error in the IGMPv3 client component. There is an IPNET security vulnerability: DoS via NULL dereference in IGMP parsing. |
5Belden NetappSiemens+2 more10E Series Santricity Os Controller Garrettcom Magnum Dx940e FirmwareHirschmann Hios+7 moreNov 21, 2024 Aug 9, 2019 N/A· v4 8.8 HIGH· v3 5.8 MEDIUM· v2 Wind River VxWorks 6.6 through 6.9 has a Buffer Overflow in the DHCP client component. There is an IPNET security vulnerability: Heap overflow in DHCP Offer/ACK parsing inside ipdhcpc. |
5Belden NetappSiemens+2 more12E Series Santricity Os Controller Garrettcom Magnum Dx940e FirmwareHirschmann Hios+9 moreNov 21, 2024 Aug 9, 2019 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 Wind River VxWorks 6.9 and vx7 has a Buffer Overflow in the IPv4 component. There is an IPNET security vulnerability: Stack overflow in the parsing of IPv4 packets’ IP options. |
3Belden SiemensWindriver7Garrettcom Magnum Dx940e Firmware Hirschmann HiosRuggedcom Win7000 Firmware+4 moreNov 21, 2024 Aug 5, 2019 N/A· v4 7.1 HIGH· v3 4.8 MEDIUM· v2 Wind River VxWorks 6.6, 6.7, 6.8, 6.9.3, 6.9.4, and Vx7 has Incorrect Access Control in IPv4 assignment by the ipdhcpc DHCP client component. |
When RPC is enabled in Wind River VxWorks 6.9 prior to 6.9.1, a specially crafted RPC request can trigger an integer overflow leading to an out-of-bounds memory copy. It may allow remote attackers to cause a denial of se...Show more |
Integer overflow in the _authenticate function in svc_auth.c in Wind River VxWorks 5.5 through 6.9.4.1, when the Remote Procedure Call (RPC) protocol is enabled, allows remote attackers to cause a denial of service (cras...Show more |
Wind River VxWorks before 5.5.1, 6.5.x through 6.7.x before 6.7.1.1, 6.8.x before 6.8.3, 6.9.x before 6.9.4.4, and 7.x before 7 ipnet_coreip 1.2.2.0, as used on Schneider Electric SAGE RTU devices before J2 and other dev...Show more |
The web server in Wind River VxWorks 5.5 through 6.9 allows remote attackers to cause a denial of service (daemon crash) via a crafted URI. |
The WebCLI component in Wind River VxWorks 5.5 through 6.9 allows remote authenticated users to cause a denial of service (CLI session crash) via a crafted command string. |
IPSSH (aka the SSH server) in Wind River VxWorks 6.5 through 6.9 allows remote attackers to execute arbitrary code or cause a denial of service (daemon hang) via a crafted public-key authentication request. |
IPSSH (aka the SSH server) in Wind River VxWorks 6.5 through 6.9 allows remote authenticated users to cause a denial of service (daemon outage) via a crafted pty request. |
IPSSH (aka the SSH server) in Wind River VxWorks 6.5 through 6.9 allows remote authenticated users to cause a denial of service (daemon outage) via a crafted packet. |
IPSSH (aka the SSH server) in Wind River VxWorks 6.5 through 6.9 allows remote attackers to cause a denial of service (daemon outage) via a crafted authentication request. |
The FTP daemon in Wind River VxWorks does not close the TCP connection after a number of failed login attempts, which makes it easier for remote attackers to obtain access via a brute-force attack. |
The loginDefaultEncrypt algorithm in loginLib in Wind River VxWorks before 6.9 does not properly support a large set of distinct possible passwords, which makes it easier for remote attackers to obtain access via a (1) t...Show more |
The INCLUDE_SECURITY functionality in Wind River VxWorks 6.x, 5.x, and earlier uses the LOGIN_USER_NAME and LOGIN_USER_PASSWORD (aka LOGIN_PASSWORD) parameters to create hardcoded credentials, which makes it easier for r...Show more |
2Rockwellautomation Windriver21756 Enbt/a Firmware VxworksMay 28, 2026 Aug 5, 2010 N/A· v4 9.8 CRITICAL· v3 10.0 HIGH· v2 The WDB target agent debug service in Wind River VxWorks 6.x, 5.x, and earlier, as used on the Rockwell Automation 1756-ENBT series A with firmware 3.2.6 and 3.6.1 and other products, allows remote attackers to read or m...Show more |
6Force10 FreebsdJuniper+3 more6Freebsd FtosJnos+3 moreApr 23, 2026 Oct 3, 2008 N/A· v4 N/A· v3 9.3 HIGH· v2 The IPv6 Neighbor Discovery Protocol (NDP) implementation in (1) FreeBSD 6.3 through 7.1, (2) OpenBSD 4.2 and 4.3, (3) NetBSD, (4) Force10 FTOS before E7.7.1.1, (5) Juniper JUNOS, and (6) Wind River VxWorks 5.x through 6...Show more |