← Back

V Series Appliances

v-series_appliances

Vendor: Websense • 11 CVEs

CVEs (11)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Websense
1V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
5.0 MEDIUM· v2
SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to read arbitrary files via unspecified vectors.
1Websense
1V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
7.5 HIGH· v2
SVM in Websense TRITON V-Series appliances before 8.0.0 allows attackers to upload arbitrary files via unspecified vectors.
1Websense
2Triton Ap Email
V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
5.0 MEDIUM· v2
The Mail Server in Websense TRITON AP-EMAIL and V-Series appliances before 8.0.0 uses plaintext credentials, which allows remote attackers to obtain sensitive information via unspecified vectors.
1Websense
1V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
6.8 MEDIUM· v2
Cross-site request forgery (CSRF) vulnerability in the command line page in Websense TRITON V-Series appliances before 8.0.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors...Show more
Cross-site request forgery (CSRF) vulnerability in the command line page in Websense TRITON V-Series appliances before 8.0.0 allows remote attackers to hijack the authentication of unspecified victims via unknown vectors.Show less
1Websense
2Triton Ap Email
V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Cross-site scripting (XSS) vulnerability in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via unspecified vectors.
1Websense
1V Series Appliances
May 6, 2026
Mar 27, 2015
N/A· v4
N/A· v3
4.0 MEDIUM· v2
Websense TRITON V-Series appliances before 7.8.3 Hotfix 03 and 7.8.4 before Hotfix 01 allow remote administrators to read arbitrary files and obtain passwords via a crafted path.
1Websense
4Triton Ap Data
Triton Ap EmailTriton Ap Web+1 more
May 6, 2026
Mar 26, 2015
N/A· v4
N/A· v3
5.0 MEDIUM· v2
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorer_wse/, which allows remote attackers to obtain sensitive information via a direct request to a (1) Web Security incident report or...Show more
Websense TRITON AP-WEB before 8.0.0 does not properly restrict access to files in explorer_wse/, which allows remote attackers to obtain sensitive information via a direct request to a (1) Web Security incident report or the (2) Explorer configuration (websense.ini) file.Show less
1Websense
2Triton
V Series Appliances
May 6, 2026
Mar 26, 2015
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Multiple cross-site scripting (XSS) vulnerabilities in the data loss prevention (DLP) incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script...Show more
Multiple cross-site scripting (XSS) vulnerabilities in the data loss prevention (DLP) incident Forensics Preview in Websense Triton 7.8.3 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via a crafted (1) email or (2) HTTP request, which triggers a DLP Policy.Show less
1Websense
2Triton
V Series Appliances
May 6, 2026
Mar 26, 2015
N/A· v4
N/A· v3
6.5 MEDIUM· v2
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute a...Show more
The network diagnostics tool (CommandLineServlet) in the Appliance Manager command line utility (CLU) in Websense TRITON 7.8.3 and V-Series appliances before 7.8.4 Hotfix 02 allows remote authenticated users to execute arbitrary commands via shell metacharacters in the "second" parameter of a command, as demonstrated by the Destination parameter in the ping command.Show less
1Websense
2Triton Ap Web
V Series Appliances
May 6, 2026
Mar 25, 2015
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Multiple cross-site scripting (XSS) vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the (1) ws-userip in the ws-encdata...Show more
Multiple cross-site scripting (XSS) vulnerabilities in Websense TRITON AP-WEB before 8.0.0 and V-Series 7.7 appliances allow remote attackers to inject arbitrary web script or HTML via the (1) ws-userip in the ws-encdata parameter to cve-bin/moreBlockInfo.cgi in the Data Security block page or (2) admin_msg parameter to configure/ssl_ui/eva-config/client-cert-import_wsoem.html in the Content Gateway, which is not properly handled in an error message.Show less
1Websense
4Triton Ap Data
Triton Ap EmailTriton Ap Web+1 more
May 6, 2026
Mar 25, 2015
N/A· v4
N/A· v3
4.3 MEDIUM· v2
Cross-site scripting (XSS) vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTM...Show more
Cross-site scripting (XSS) vulnerability in the Message Log in the Email Security Gateway in Websense TRITON AP-EMAIL before 8.0.0 and V-Series 7.7 appliances allows remote attackers to inject arbitrary web script or HTML via the sender address in an email.Show less