CVEs (34)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the adslPwd parameter of the formWanParameterSetting function. |
Tenda F1203 V2.0.1.6 firmware has a stack overflow vulnerability located in the PPW parameter of the fromWizardHandle function. |
A vulnerability classified as critical was found in Tenda F1203 2.0.1.6. This vulnerability affects the function setSchedWifi of the file /goform/openSchedWifi. The manipulation of the argument schedStartTime/schedEndTim...Show more |
A vulnerability classified as critical has been found in Tenda F1203 2.0.1.6. This affects the function formSetCfm of the file /goform/setcfm. The manipulation of the argument funcpara1 leads to stack-based buffer overfl...Show more |
A vulnerability was found in Tenda F1203 2.0.1.6. It has been rated as critical. Affected by this issue is the function formQuickIndex of the file /goform/QuickIndex. The manipulation of the argument PPPOEPassword leads...Show more |
A vulnerability was found in Tenda F1203 2.0.1.6. It has been declared as critical. Affected by this vulnerability is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument p...Show more |
1Tenda 3F1203 Firmware Fh1203 FirmwareFh1205 FirmwareNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the ssid parameter in the form_fast_setting_wifi_set function. |
1Tenda 9Ac10 Firmware Ac1206 FirmwareAc5 Firmware+6 moreNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a s...Show more |
1Tenda 3F1203 Firmware Fh1203 FirmwareFh1205 FirmwareNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda F1203 V2.0.1.6, FH1203 V2.0.1.6 and FH1205 V2.0.0.7(775) was discovered to contain a stack overflow via the deviceId parameter in the formSetDeviceName function. |
1Tenda 9Ac10 Firmware Ac1206 FirmwareAc5 Firmware+6 moreNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the dev...Show more |
1Tenda 8Ac10 Firmware Ac1206 FirmwareAc5 Firmware+5 moreNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to c...Show more |
1Tenda 5Ac5 Firmware Ac7 FirmwareAc9 Firmware+2 moreNov 21, 2024 Aug 7, 2023 N/A· v4 9.8 CRITICAL· v3 N/A· v2 Tenda AC7 V1.0,V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0,V15.03.06.28, AC9 V3.0,V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the addWifiMacFilter func...Show more |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the time parameter at /goform/saveParentControlInfo. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/saveParentControlInfo. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/RouteStatic. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/NatStaticSetting. |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand. |