← Back

Ac10 Firmware

ac10_firmware

Vendor: Tenda • 92 CVEs

CVEs (92)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Tenda
1Ac10 Firmware
Apr 22, 2025
Apr 17, 2025
N/A· v4
7.5 HIGH· v3
N/A· v2
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via cloneType2.
1Tenda
1Ac10 Firmware
Apr 22, 2025
Apr 15, 2025
N/A· v4
4.6 MEDIUM· v3
N/A· v2
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serverName2.
1Tenda
1Ac10 Firmware
Apr 22, 2025
Apr 15, 2025
N/A· v4
4.6 MEDIUM· v3
N/A· v2
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via serviceName2.
1Tenda
1Ac10 Firmware
Apr 22, 2025
Apr 15, 2025
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 V4.0si_V16.03.10.20 is vulnerable to Buffer Overflow in AdvSetMacMtuWan via mac2.
1Tenda
1Ac10 Firmware
Apr 9, 2025
Apr 3, 2025
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-base...Show more
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function ShutdownSetAdd of the file /goform/ShutdownSetAdd. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac10 Firmware
Mar 17, 2025
Feb 20, 2025
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variab...Show more
Tenda AC10 V1.0 V15.03.06.23 has a command injection vulnerablility located in the formexeCommand function. The str variable receives the cmdinput parameter from a POST request and is later assigned to the cmd_buf variable, which is directly used in the doSystemCmd function, causing an arbitrary command execution.Show less
1Tenda
1Ac10 Firmware
Mar 17, 2025
Feb 20, 2025
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 V1.0 V15.03.06.23 is vulnerable to Buffer Overflow in form_fast_setting_wifi_set via the parameter ssid.
1Tenda
3Ac10 Firmware
Ac18 FirmwareAc8 Firmware
May 28, 2025
Jan 17, 2025
8.6 HIGH· v4
7.2 HIGH· v3
8.3 HIGH· v2
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Han...Show more
A vulnerability, which was classified as critical, has been found in Tenda AC8, AC10 and AC18 16.03.10.20. Affected by this issue is some unknown functionality of the file /goform/telnet of the component HTTP Request Handler. The manipulation leads to command injection. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac10 Firmware
Nov 19, 2024
Nov 15, 2024
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTi...Show more
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetSysAutoRebbotCfg. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac10 Firmware
Nov 13, 2024
Nov 11, 2024
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone...Show more
A vulnerability classified as critical was found in Tenda AC10 16.03.10.13. Affected by this vulnerability is the function FUN_0044db3c of the file /goform/fast_setting_wifi_set. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac10 Firmware
Nov 14, 2024
Nov 10, 2024
8.7 HIGH· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stac...Show more
A vulnerability, which was classified as critical, was found in Tenda AC10 16.03.10.13. Affected is the function FUN_0046AC38 of the file /goform/WifiExtraSet. The manipulation of the argument wpapsk_crypto leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
10Ac10 Firmware
Ac10u FirmwareAc1206 Firmware+7 more
Nov 1, 2024
Oct 23, 2024
7.1 HIGH· v4
7.5 HIGH· v3
6.8 MEDIUM· v2
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV...Show more
A vulnerability was found in Tenda AC6, AC7, AC8, AC9, AC10, AC10U, AC15, AC18, AC500 and AC1206 up to 20241022. It has been rated as problematic. This issue affects the function websReadEvent of the file /goform/GetIPTV. The manipulation of the argument Content-Length leads to null pointer dereference. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used.Show less
1Tenda
1Ac10 Firmware
Jul 7, 2025
Jul 29, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
Buffer Overflow vulnerability in Tenda AC10 v4 US_AC10V4.0si_V16.03.10.20_cn allows a remote attacker to execute arbitrary code via the Virtual_Data_Check function in the bin/httpd component.
1Tenda
1Ac10 Firmware
Mar 17, 2025
Apr 17, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
Tenda AC10 v4.0 V16.03.10.13 and V16.03.10.20 firmware has a stack overflow vulnerability via the adslPwd parameter in the formWanParameterSetting function.
1Tenda
1Ac10 Firmware
Nov 21, 2024
Mar 24, 2024
N/A· v4
9.8 CRITICAL· v3
9.0 HIGH· v2
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the ar...Show more
A vulnerability, which was classified as critical, has been found in Tenda AC10 16.03.10.13/16.03.10.20. Affected by this issue is the function fromSetSysTime of the file /goform/SetSysTimeCfg. The manipulation of the argument timeZone leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. The identifier of this vulnerability is VDB-257780. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.Show less
1Tenda
1Ac10 Firmware
Jan 22, 2025
Mar 18, 2024
N/A· v4
8.8 HIGH· v3
9.0 HIGH· v2
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to sta...Show more
A vulnerability was found in Tenda AC10 16.03.10.13 and classified as critical. This issue affects the function fromSetRouteStatic of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-257081 was assigned to this vulnerability.Show less
1Tenda
1Ac10 Firmware
Mar 17, 2025
Feb 15, 2024
N/A· v4
4.6 MEDIUM· v3
N/A· v2
Tenda AC10V4.0 V16.03.10.20 was discovered to contain a stack overflow via the page parameter in the sub_49B384 function.
1Tenda
1Ac10 Firmware
Nov 21, 2024
Nov 29, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the shareSpeed parameter in the function fromSetWifiGuestBasic.
1Tenda
1Ac10 Firmware
Nov 21, 2024
Nov 29, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the time parameter in the function compare_parentcontrol_time.
1Tenda
1Ac10 Firmware
Nov 21, 2024
Nov 29, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Tenda AC10 version US_AC10V4.0si_V16.03.10.13_cn was discovered to contain a stack overflow via the urls parameter in the function get_parentControl_list_Info.