← Back

Simatic S7 1500 Software Controller Firmware

simatic_s7-1500_software_controller_firmware

Vendor: Siemens • 8 CVEs

CVEs (8)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Siemens
73Simatic Drive Controller Cpu 1504d Tf Firmware
Simatic Drive Controller Cpu 1507d Tf FirmwareSimatic Et 200sp Open Control 1515sp Pc2 Firmware+70 more
Jun 17, 2026
Dec 12, 2023
N/A· v4
7.5 HIGH· v3
N/A· v2
Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations.
1Siemens
78Simatic Cloud Connect 7 Cc712 Firmware
Simatic Cloud Connect 7 Cc716 FirmwareSimatic Drive Controller Cpu 1504d Tf Firmware+75 more
Jun 17, 2026
Sep 12, 2023
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow...Show more
The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate.Show less
1Siemens
96Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware
Simatic S7 1200 Cpu 1211c FirmwareSimatic S7 1200 Cpu 1212c Firmware+93 more
Jun 17, 2026
Dec 13, 2022
N/A· v4
7.5 HIGH· v3
N/A· v2
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
1Siemens
92Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware
Simatic S7 1200 Cpu 1211c FirmwareSimatic S7 1200 Cpu 1212c Firmware+89 more
Jun 17, 2026
Dec 13, 2022
N/A· v4
7.5 HIGH· v3
N/A· v2
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
1Siemens
96Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware
Simatic S7 1200 Cpu 1211c FirmwareSimatic S7 1200 Cpu 1212c Firmware+93 more
Jun 17, 2026
Dec 13, 2022
N/A· v4
7.5 HIGH· v3
N/A· v2
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
1Siemens
96Simatic Et 200 Sp Open Controller Cpu 1515sp Pc Firmware
Simatic S7 1200 Cpu 1211c FirmwareSimatic S7 1200 Cpu 1212c Firmware+93 more
Jun 17, 2026
Dec 13, 2022
N/A· v4
7.5 HIGH· v3
N/A· v2
Affected devices don't process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device.
1Siemens
2Simatic Et 200sp Open Controller Firmware
Simatic S7 1500 Software Controller Firmware
Jun 17, 2026
Dec 14, 2020
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that...Show more
A vulnerability has been identified in SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) (V20.8), SIMATIC S7-1500 Software Controller (V20.8). The web server of the affected products contains a vulnerability that could allow a remote attacker to trigger a denial-of-service condition by sending a specially crafted HTTP request.Show less
1Siemens
93Dk Standard Ethernet Controller Firmware
Ek Ertec 200 Pn Io FirmwareEk Ertec 200p Pn Io Firmware+90 more
May 13, 2026
May 11, 2017
7.1 HIGH· v4
6.5 MEDIUM· v3
6.1 MEDIUM· v2
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interf...Show more
Specially crafted PROFINET DCP broadcast packets could cause a denial of service condition of affected products on a local Ethernet segment (Layer 2). Human interaction is required to recover the systems. PROFIBUS interfaces are not affected.Show less