← Back

Sicam A8000 Cp 8050 Firmware

sicam_a8000_cp-8050_firmware

Vendor: Siemens • 3 CVEs

CVEs (3)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Siemens
2Sicam A8000 Cp 8031 Firmware
Sicam A8000 Cp 8050 Firmware
Nov 21, 2024
Jan 9, 2024
N/A· v4
7.2 HIGH· v3
N/A· v2
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in...Show more
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05.20), CP-8050 MASTER MODULE (All versions < CPCI85 V05.20). The network configuration service of affected devices contains a flaw in the conversion of ipv4 addresses that could lead to an uninitialized variable being used in succeeding validation steps. By uploading specially crafted network configuration, an authenticated remote attacker could be able to inject commands that are executed on the device with root privileges during device startup.Show less
1Siemens
2Sicam A8000 Cp 8031 Firmware
Sicam A8000 Cp 8050 Firmware
Nov 21, 2024
Apr 12, 2022
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < V4.80). Affected devices do not require an user to be authenticated to access certain files. This cou...Show more
A vulnerability has been identified in SICAM A8000 CP-8031 (All versions < V4.80), SICAM A8000 CP-8050 (All versions < V4.80). Affected devices do not require an user to be authenticated to access certain files. This could allow unauthenticated attackers to download these files.Show less
1Siemens
3Sicam A8000 Cp 8000 Firmware
Sicam A8000 Cp 802x FirmwareSicam A8000 Cp 8050 Firmware
Nov 21, 2024
Mar 21, 2019
N/A· v4
7.5 HIGH· v3
7.8 HIGH· v2
A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP...Show more
A vulnerability has been identified in SICAM A8000 CP-8000 (All versions < V14), SICAM A8000 CP-802X (All versions < V14), SICAM A8000 CP-8050 (All versions < V2.00). Specially crafted network packets sent to port 80/TCP or 443/TCP could allow an unauthenticated remote attacker to cause a Denial-of-Service condition of the web server. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 80/TCP or 443/TCP. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the web server. A system reboot is required to recover the web service of the device. At the time of advisory update, exploit code for this security vulnerability is public.Show less