CVEs (13)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Feb 16, 2024 N/A· v4 8.8 HIGH· v3 N/A· v2 A privilege escalation vulnerability exists in Rockwell Automation FactoryTalk® Service Platform (FTSP). If exploited, a malicious user with basic user group privileges could potentially sign into the software and recei...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Jan 31, 2024 N/A· v4 9.1 CRITICAL· v3 N/A· v2 A vulnerability exists in Rockwell Automation FactoryTalk® Service Platform that allows a malicious user to obtain the service token and use it for authentication on another FTSP directory. This is due to the lack of dig...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Oct 27, 2023 N/A· v4 8.1 HIGH· v3 N/A· v2 Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk® Services Platform web service and then use the token to log in into...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Apr 1, 2022 N/A· v4 8.8 HIGH· v3 6.0 MEDIUM· v2 Rockwell Automation FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed contains a vulnerability that may allow a remote, authenticated attacker to bypass FactoryTalk Security...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Feb 24, 2022 N/A· v4 7.1 HIGH· v3 5.6 MEDIUM· v2 A local, authenticated attacker could use an XML External Entity (XXE) attack to exploit weakly configured XML files to access local or remote content. A successful exploit could potentially cause a denial-of-service con...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Mar 18, 2021 N/A· v4 10.0 CRITICAL· v3 7.5 HIGH· v2 In Rockwell Automation FactoryTalk Services Platform Versions 6.10.00 and 6.11.00, there is an issue with the implementation of the SHA-256 hashing algorithm with FactoryTalk Services Platform that prevents the user pass...Show more |
1Rockwellautomation 3Factorytalk Services Platform Rslogix 5000Studio 5000 Logix DesignerJun 17, 2026 Mar 3, 2021 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Jun 23, 2020 N/A· v4 8.8 HIGH· v3 5.8 MEDIUM· v2 In Rockwell Automation FactoryTalk Services Platform, all versions, the redundancy host service (RdcyHost.exe) does not validate supplied identifiers, which could allow an unauthenticated, adjacent attacker to execute re...Show more |
1Rockwellautomation 1Factorytalk Services Platform Jun 17, 2026 Mar 23, 2020 N/A· v4 9.8 CRITICAL· v3 10.0 HIGH· v2 In Rockwell Automation all versions of FactoryTalk Diagnostics software, a subsystem of the FactoryTalk Services Platform, FactoryTalk Diagnostics exposes a .NET Remoting endpoint via RNADiagnosticsSrv.exe at TCPtcp/8082...Show more |
1Rockwellautomation 1Factorytalk Services Platform Nov 21, 2024 Jan 24, 2019 N/A· v4 7.5 HIGH· v3 7.8 HIGH· v2 In Rockwell Automation FactoryTalk Services Platform 2.90 and earlier, a remote unauthenticated attacker could send numerous crafted packets to service ports resulting in memory consumption that could lead to a partial o...Show more |
1Rockwellautomation 2Factorytalk Services Platform Factorytalk View StudioMay 6, 2026 Mar 31, 2015 N/A· v4 N/A· v3 6.9 MEDIUM· v2 Untrusted search path vulnerability in the Clean Utility application in Rockwell Automation FactoryTalk Services Platform before 2.71.00 and FactoryTalk View Studio 8.00.00 and earlier allows local users to gain privileg...Show more |
1Rockwellautomation 1Factorytalk Services Platform Apr 29, 2026 Apr 18, 2013 N/A· v4 N/A· v3 7.8 HIGH· v2 Integer overflow in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause a denia...Show more |
1Rockwellautomation 1Factorytalk Services Platform Apr 29, 2026 Apr 18, 2013 N/A· v4 N/A· v3 7.8 HIGH· v2 Integer signedness error in RNADiagnostics.dll in Rockwell Automation FactoryTalk Services Platform (FTSP) CPR9, CPR9-SR1, CPR9-SR2, CPR9-SR3, CPR9-SR4, CPR9-SR5, CPR9-SR5.1, and CPR9-SR6 allows remote attackers to cause...Show more |