← Back

1756 En2t Series D Firmware

1756-en2t_series_d_firmware

Vendor: Rockwellautomation • 3 CVEs

CVEs (3)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Rockwellautomation
331756 En2f Series A Firmware
1756 En2f Series B Firmware1756 En2f Series C Firmware+30 more
Jun 17, 2026
Sep 20, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. T...Show more
A buffer overflow vulnerability exists in the Rockwell Automation select 1756-EN* communication devices. If exploited, a threat actor could potentially leverage this vulnerability to perform a remote code execution. To exploit this vulnerability, a threat actor would have to send a maliciously crafted CIP request to device. Show less
1Rockwellautomation
121756 En2f Series A Firmware
1756 En2f Series B Firmware1756 En2f Series C Firmware+9 more
Jun 17, 2026
Jul 12, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target sys...Show more
Where this vulnerability exists in the Rockwell Automation 1756 EN2* and 1756 EN3* ControlLogix communication products, it could allow a malicious user to perform remote code execution with persistence on the target system through maliciously crafted CIP messages. This includes the ability to modify, deny, and exfiltrate data passing through the device. Show less
1Rockwellautomation
161756 En2f Series A Firmware
1756 En2f Series B Firmware1756 En2f Series C Firmware+13 more
Jun 3, 2026
Dec 7, 2018
N/A· v4
8.6 HIGH· v3
7.8 HIGH· v2
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connecti...Show more
Rockwell Automation MicroLogix 1400 Controllers and 1756 ControlLogix Communications Modules An unauthenticated, remote threat actor could send a CIP connection request to an affected device, and upon successful connection, send a new IP configuration to the affected device even if the controller in the system is set to Hard RUN mode. When the affected device accepts this new IP configuration, a loss of communication occurs between the device and the rest of the system as the system traffic is still attempting to communicate with the device via the overwritten IP address.Show less