← Back

Clinical Collaboration Platform

clinical_collaboration_platform

Vendor: Philips • 8 CVEs

CVEs (8)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Jun 2, 2025
N/A· v4
6.5 MEDIUM· v3
N/A· v2
Clinical Collaboration Platform 12.2.1.5 has a weak logout system where the session token remains valid after logout and allows a remote attacker to obtain sensitive information and execute arbitrary code.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Jun 2, 2025
N/A· v4
6.5 MEDIUM· v3
N/A· v2
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the usertoken function of default.aspx.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Jun 2, 2025
N/A· v4
6.5 MEDIUM· v3
N/A· v2
An issue in Clinical Collaboration Platform 12.2.1.5 allows a remote attacker to obtain sensitive information and execute arbitrary code via the session management component.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Sep 18, 2020
N/A· v4
7.1 HIGH· v3
3.6 LOW· v2
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, exposes a resource to the wrong control sphere, providing unintended actors with inappropriate access to the resource.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Sep 18, 2020
N/A· v4
6.5 MEDIUM· v3
3.3 LOW· v2
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources co...Show more
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not properly control the allocation and maintenance of a limited resource, thereby enabling an attacker to influence the amount of resources consumed, eventually leading to the exhaustion of available resources.Show less
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Sep 18, 2020
N/A· v4
6.3 MEDIUM· v3
5.8 MEDIUM· v2
When an attacker claims to have a given identity, Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not prove or insufficiently proves the claim is correct.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Sep 18, 2020
N/A· v4
3.5 LOW· v3
2.7 LOW· v2
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior, does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output used as a webpage that is served to other users.
1Philips
1Clinical Collaboration Platform
Jun 17, 2026
Sep 18, 2020
N/A· v4
4.3 MEDIUM· v3
4.3 MEDIUM· v2
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data saf...Show more
Philips Clinical Collaboration Platform, Versions 12.2.1 and prior. The product receives input or data, but it does not validate or incorrectly validates that the input has the properties required to process the data safely and correctly.Show less