← Back

Nj501 4310 Firmware

nj501-4310_firmware

Vendor: Omron • 5 CVEs

CVEs (5)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Omron
55Nj Pa3001 Firmware
Nj Pd3001 FirmwareNj101 1000 Firmware+52 more
Jun 17, 2026
Jun 24, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to det...Show more
Insufficient verification of data authenticity issue exists in NJ Series CPU Unit all versions and NX Series CPU Unit all versions. If a user program in the affected product is altered, the product may not be able to detect the alteration.Show less
1Omron
271Cj2h Cpu64 Eip Firmware
Cj2h Cpu64 FirmwareCj2h Cpu65 Eip Firmware+268 more
Jun 17, 2026
Jun 19, 2023
N/A· v4
9.8 CRITICAL· v3
N/A· v2
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON...Show more
FINS (Factory Interface Network Service) is a message communication protocol, which is designed to be used in closed FA (Factory Automation) networks, and is used in FA networks composed of OMRON products. Multiple OMRON products that implement FINS protocol contain following security issues -- (1)Plaintext communication, and (2)No authentication required. When FINS messages are intercepted, the contents may be retrieved. When arbitrary FINS messages are injected, any commands may be executed on, or the system information may be retrieved from, the affected device. Affected products and versions are as follows: SYSMAC CS-series CPU Units, all versions, SYSMAC CJ-series CPU Units, all versions, SYSMAC CP-series CPU Units, all versions, SYSMAC NJ-series CPU Units, all versions, SYSMAC NX1P-series CPU Units, all versions, SYSMAC NX102-series CPU Units, all versions, and SYSMAC NX7 Database Connection CPU Units (Ver.1.16 or later)Show less
1Omron
57Na5 12w Firmware
Na5 15w FirmwareNa5 7w Firmware+54 more
Jun 17, 2026
Jul 4, 2022
N/A· v4
8.1 HIGH· v3
6.8 MEDIUM· v2
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation contr...Show more
Use of hard-coded credentials vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who successfully obtained the user credentials by analyzing the affected product to access the controller.Show less
1Omron
52Nj Pa3001 Firmware
Nj Pd3001 FirmwareNj101 1000 Firmware+49 more
Jun 17, 2026
Jul 4, 2022
N/A· v4
7.5 HIGH· v3
5.4 MEDIUM· v2
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine au...Show more
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, and Machine automation controller NJ series all models V 1.48 and earlier, which may allow an adjacent attacker who can analyze the communication between the controller and the specific software used by OMRON internally to cause a denial-of-service (DoS) condition or execute a malicious program.Show less
1Omron
57Na5 12w Firmware
Na5 15w FirmwareNa5 7w Firmware+54 more
Jun 17, 2026
Jul 4, 2022
N/A· v4
8.1 HIGH· v3
6.8 MEDIUM· v2
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automa...Show more
Authentication bypass by capture-replay vulnerability exists in Machine automation controller NJ series all models V 1.48 and earlier, Machine automation controller NX7 series all models V1.28 and earlier, Machine automation controller NX1 series all models V1.48 and earlier, Automation software 'Sysmac Studio' all models V1.49 and earlier, and Programmable Terminal (PT) NA series NA5-15W/NA5-12W/NA5-9W/NA5-7W models Runtime V1.15 and earlier, which may allow a remote attacker who can analyze the communication between the affected controller and automation software 'Sysmac Studio' and/or a Programmable Terminal (PT) to access the controller.Show less