← Back

Cx Programmer

cx-programmer

Vendor: Omron • 28 CVEs

CVEs (28)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Omron
3Cx One
Cx ProgrammerCx Server
Nov 21, 2024
Dec 4, 2018
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the a...Show more
Two stack-based buffer overflow vulnerabilities have been discovered in CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior). When processing project files, the application allows input data to exceed the buffer. An attacker could use a specially crafted project file to overflow the buffer and execute code under the privileges of the application.Show less
1Omron
3Cx One
Cx ProgrammerCx Server
Nov 21, 2024
Dec 4, 2018
N/A· v4
7.8 HIGH· v3
6.8 MEDIUM· v2
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attac...Show more
In CX-One Versions 4.42 and prior (CX-Programmer Versions 9.66 and prior and CX-Server Versions 5.0.23 and prior), when processing project files, the application fails to check if it is referencing freed memory. An attacker could use a specially crafted project file to exploit and execute code under the privileges of the application.Show less
1Omron
7Cx Flnet
Cx OneCx Programmer+4 more
Jun 17, 2026
Apr 17, 2018
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior...Show more
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a heap-based buffer overflow.Show less
1Omron
7Cx Flnet
Cx OneCx Programmer+4 more
Jun 17, 2026
Apr 17, 2018
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior...Show more
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may allow the pointer to call an incorrect object resulting in an access of resource using incompatible type condition.Show less
1Omron
7Cx Flnet
Cx OneCx Programmer+4 more
Jun 17, 2026
Apr 17, 2018
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior...Show more
Parsing malformed project files in Omron CX-One versions 4.42 and prior, including the following applications: CX-FLnet versions 1.00 and prior, CX-Protocol versions 1.992 and prior, CX-Programmer versions 9.65 and prior, CX-Server versions 5.0.22 and prior, Network Configurator versions 3.63 and prior, and Switch Box Utility versions 1.68 and prior, may cause a stack-based buffer overflow.Show less
1Omron
3Cj2h Plc
Cj2m PlcCx Programmer
May 6, 2026
Oct 6, 2015
N/A· v4
N/A· v3
2.1 LOW· v2
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 use a reversible format for password storage in object files on Compact Flash cards, which makes it easier for local use...Show more
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 use a reversible format for password storage in object files on Compact Flash cards, which makes it easier for local users to obtain sensitive information by reading a file.Show less
1Omron
1Cx Programmer
May 6, 2026
Oct 6, 2015
N/A· v4
N/A· v3
2.1 LOW· v2
Omron CX-One CX-Programmer before 9.6 uses a reversible format for password storage in project source-code files, which makes it easier for local users to obtain sensitive information by reading a file.
1Omron
3Cj2h Plc
Cj2m PlcCx Programmer
Jun 2, 2026
Oct 6, 2015
N/A· v4
10.0 CRITICAL· v3
5.0 MEDIUM· v2
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the n...Show more
Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request.Show less