← Back

Nextscale N1200 Enclosure Firmware

nextscale_n1200_enclosure_firmware

Vendor: Lenovo • 5 CVEs

CVEs (5)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Lenovo
68Nextscale N1200 Enclosure Firmware
Thinkagile 2u4n FirmwareThinkagile Cp Cb 10 Firmware+65 more
Jul 28, 2025
Apr 15, 2024
N/A· v4
7.2 HIGH· v3
N/A· v2
A command injection vulnerability was identified in SMM/SMM2 and FPC that could allow an authenticated user with elevated privileges to execute system commands when performing a specific administrative function.
1Lenovo
8Nextscale N1200 Enclosure Firmware
Thinkagile Cp Cb 10 FirmwareThinkagile Cp Cb 10e Firmware+5 more
Nov 21, 2024
Jun 26, 2023
N/A· v4
6.3 MEDIUM· v3
N/A· v2
A valid, authenticated user with limited privileges may be able to use specifically crafted web management server API calls to execute a limited number of commands on SMM v1, SMM v2, and FPC that the user does not normal...Show more
A valid, authenticated user with limited privileges may be able to use specifically crafted web management server API calls to execute a limited number of commands on SMM v1, SMM v2, and FPC that the user does not normally have sufficient privileges to execute.Show less
1Lenovo
8Nextscale N1200 Enclosure Firmware
Thinkagile Cp Cb 10 FirmwareThinkagile Cp Cb 10e Firmware+5 more
Nov 21, 2024
Jun 26, 2023
N/A· v4
7.5 HIGH· v3
N/A· v2
An unauthenticated  denial of service vulnerability exists in the SMM v1, SMM v2, and FPC management web server which can be triggered under crafted conditions. Rebooting SMM or FPC will restore access to the management...Show more
An unauthenticated  denial of service vulnerability exists in the SMM v1, SMM v2, and FPC management web server which can be triggered under crafted conditions. Rebooting SMM or FPC will restore access to the management web server.Show less
2Ibm
Lenovo
5Nextscale Fan Power Controller Firmware
Nextscale N1200 Enclosure FirmwareThinkagile Hx Enclosure Certified Node Firmware+2 more
Nov 21, 2024
Apr 22, 2022
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated att...Show more
An authentication bypass vulnerability was discovered in an internal service of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware during an that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected.Show less
2Ibm
Lenovo
5Nextscale Fan Power Controller Firmware
Nextscale N1200 Enclosure FirmwareThinkagile Hx Enclosure Certified Node Firmware+2 more
Nov 21, 2024
Apr 22, 2022
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
An authentication bypass vulnerability was discovered in the web interface of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware that could allow an unauthenticated attacker to exe...Show more
An authentication bypass vulnerability was discovered in the web interface of the Lenovo Fan Power Controller2 (FPC2) and Lenovo System Management Module (SMM) firmware that could allow an unauthenticated attacker to execute commands on the SMM and FPC2. SMM2 is not affected.Show less