← Back

Rtu530 Firmware

rtu530_firmware

Vendor: Hitachienergy • 6 CVEs

CVEs (6)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Feb 24, 2026
8.7 HIGH· v4
7.5 HIGH· v3
N/A· v2
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communica...Show more
IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. Product is only affected if IEC 60870-5-104 bi-directional functionality is configured. Enabling secure communication following IEC 62351-3 does not remediate the vulnerability but mitigates the risk of exploitation.Show less
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Feb 24, 2026
5.3 MEDIUM· v4
5.3 MEDIUM· v3
N/A· v2
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to acces...Show more
RTU500 web interface: An unprivileged user can read user management information. The information cannot be accessed via the RTU500 web user interface but requires further tools like browser development utilities to access them without required privileges.Show less
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Jan 4, 2024
N/A· v4
7.5 HIGH· v3
N/A· v2
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially cra...Show more
A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. If the HCI Modbus TCP is enabled and configured, an attacker could exploit the vulnerability by sending a specially crafted message to the RTU500 in a high rate, causing the targeted RTU500 CMU to reboot. The vulnerability is caused by a lack of flood control which eventually if exploited causes an internal stack overflow in the HCI Modbus TCP function.Show less
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Dec 14, 2023
N/A· v4
6.1 MEDIUM· v3
N/A· v2
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized...Show more
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to user input being improperly sanitized. Show less
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Dec 4, 2023
N/A· v4
6.1 MEDIUM· v3
N/A· v2
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endle...Show more
A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. Incomplete or wrong received APDU frame layout may cause blocking on link layer. Error reason was an endless blocking when reading incoming frames on link layer with wrong length information of APDU or delayed reception of data octets. Only communication link of affected HCI IEC 60870-5-104 is blocked. If attack sequence stops the communication to the previously attacked link gets normal again. Show less
1Hitachienergy
4Rtu520 Firmware
Rtu530 FirmwareRtu540 Firmware+1 more
Jun 17, 2026
Dec 4, 2023
N/A· v4
6.1 MEDIUM· v3
N/A· v2
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly...Show more
A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. A malicious actor could perform cross-site scripting on the webserver due to an RDT language file being improperly sanitized. Show less