← Back

Debian Linux

debian_linux

Vendor: Debian • 10,001 CVEs

CVEs (10,001)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
4Debian
FedoraprojectLibtiff+1 more
4Debian Linux
FedoraLibtiff+1 more
Jun 17, 2026
Mar 11, 2022
N/A· v4
5.5 MEDIUM· v3
4.3 MEDIUM· v2
Unchecked Return Value to NULL Pointer Dereference in tiffcrop in libtiff 4.3.0 allows attackers to cause a denial-of-service via a crafted tiff file. For users that compile libtiff from sources, the fix is available wit...Show more
Unchecked Return Value to NULL Pointer Dereference in tiffcrop in libtiff 4.3.0 allows attackers to cause a denial-of-service via a crafted tiff file. For users that compile libtiff from sources, the fix is available with commit f2b656e2.Show less
2Debian
Horde
2Debian Linux
Horde Mime Viewer
Jun 17, 2026
Mar 11, 2022
N/A· v4
5.4 MEDIUM· v3
3.5 LOW· v2
lib/Horde/Mime/Viewer/Ooo.php in Horde Mime_Viewer before 2.2.4 allows XSS via an OpenOffice document, leading to account takeover in Horde Groupware Webmail Edition. This occurs after XSLT rendering.
4Debian
FasterxmlNetapp+1 more
36Active Iq Unified Manager
Big Data Spatial And GraphCloud Insights Acquisition Unit+33 more
Jun 17, 2026
Mar 11, 2022
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
jackson-databind before 2.13.0 allows a Java StackOverflow exception and denial of service via a large depth of nested objects.
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Xen
2Debian Linux
Xen
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.0 HIGH· v3
4.4 MEDIUM· v2
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device fronten...Show more
Linux PV device frontends vulnerable to attacks by backends T[his CNA information record relates to multiple CVEs; the text explains which aspects/vulnerabilities correspond to which CVE.] Several Linux PV device frontends are using the grant table interfaces for removing access rights of the backends in ways being subject to race conditions, resulting in potential data leaks, data corruption by malicious backends, and denial of service triggered by malicious backends: blkfront, netfront, scsifront and the gntalloc driver are testing whether a grant reference is still in use. If this is not the case, they assume that a following removal of the granted access will always succeed, which is not true in case the backend has mapped the granted page between those two operations. As a result the backend can keep access to the memory page of the guest no matter how the page will be used after the frontend I/O has finished. The xenbus driver has a similar problem, as it doesn't check the success of removing the granted access of a shared ring buffer. blkfront: CVE-2022-23036 netfront: CVE-2022-23037 scsifront: CVE-2022-23038 gntalloc: CVE-2022-23039 xenbus: CVE-2022-23040 blkfront, netfront, scsifront, usbfront, dmabuf, xenbus, 9p, kbdfront, and pvcalls are using a functionality to delay freeing a grant reference until it is no longer in use, but the freeing of the related data page is not synchronized with dropping the granted access. As a result the backend can keep access to the memory page even after it has been freed and then re-used for a different purpose. CVE-2022-23041 netfront will fail a BUG_ON() assertion if it fails to revoke access in the rx path. This will result in a Denial of Service (DoS) situation of the guest which can be triggered by the backend. CVE-2022-23042Show less
2Debian
Spip
2Debian Linux
Spip
Jun 17, 2026
Mar 10, 2022
N/A· v4
5.3 MEDIUM· v3
5.0 MEDIUM· v2
SPIP before 3.2.14 and 4.x before 4.0.5 allows unauthenticated access to information about editorial objects.
2Debian
Spip
2Debian Linux
Spip
Jun 17, 2026
Mar 10, 2022
N/A· v4
8.8 HIGH· v3
6.5 MEDIUM· v2
SPIP before 3.2.14 and 4.x before 4.0.5 allows remote authenticated editors to execute arbitrary code.
2Debian
Tryton
3Debian Linux
ProteusTrytond
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.5 HIGH· v3
5.0 MEDIUM· v2
An XML Entity Expansion (XEE) issue was discovered in Tryton Application Platform (Server) 5.x through 5.0.45, 6.x through 6.0.15, and 6.1.x and 6.2.x through 6.2.5, and Tryton Application Platform (Command Line Client (...Show more
An XML Entity Expansion (XEE) issue was discovered in Tryton Application Platform (Server) 5.x through 5.0.45, 6.x through 6.0.15, and 6.1.x and 6.2.x through 6.2.5, and Tryton Application Platform (Command Line Client (proteus)) 5.x through 5.0.11, 6.x through 6.0.4, and 6.1.x and 6.2.x through 6.2.1. An unauthenticated user can send a crafted XML-RPC message to consume all the resources of the server.Show less
2Debian
Tryton
3Debian Linux
ProteusTrytond
Jun 17, 2026
Mar 10, 2022
N/A· v4
6.5 MEDIUM· v3
4.0 MEDIUM· v2
An XXE issue was discovered in Tryton Application Platform (Server) 5.x through 5.0.45, 6.x through 6.0.15, and 6.1.x and 6.2.x through 6.2.5, and Tryton Application Platform (Command Line Client (proteus)) 5.x through 5...Show more
An XXE issue was discovered in Tryton Application Platform (Server) 5.x through 5.0.45, 6.x through 6.0.15, and 6.1.x and 6.2.x through 6.2.5, and Tryton Application Platform (Command Line Client (proteus)) 5.x through 5.0.11, 6.x through 6.0.4, and 6.1.x and 6.2.x through 6.2.1. An authenticated user can make the server parse a crafted XML SEPA file to access arbitrary files on the system.Show less
2Debian
Postgresql
2Debian Linux
Postgresql Jdbc Driver
Jun 17, 2026
Mar 10, 2022
N/A· v4
9.8 CRITICAL· v3
7.5 HIGH· v2
In pgjdbc before 42.3.3, an attacker (who controls the jdbc URL or properties) can call java.util.logging.FileHandler to write to arbitrary files through the loggerFile and loggerLevel connection properties. An example s...Show more
In pgjdbc before 42.3.3, an attacker (who controls the jdbc URL or properties) can call java.util.logging.FileHandler to write to arbitrary files through the loggerFile and loggerLevel connection properties. An example situation is that an attacker could create an executable JSP file under a Tomcat web root. NOTE: the vendor's position is that there is no pgjdbc vulnerability; instead, it is a vulnerability for any application to use the pgjdbc driver with untrusted connection propertiesShow less
4Debian
FedoraprojectLibtiff+1 more
4Active Iq Unified Manager
Debian LinuxFedora+1 more
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.1 HIGH· v3
5.8 MEDIUM· v2
A heap buffer overflow in ExtractImageSection function in tiffcrop.c in libtiff library Version 4.3.0 allows attacker to trigger unsafe or out of bounds memory access via crafted TIFF image file which could result into a...Show more
A heap buffer overflow in ExtractImageSection function in tiffcrop.c in libtiff library Version 4.3.0 allows attacker to trigger unsafe or out of bounds memory access via crafted TIFF image file which could result into application crash, potential information disclosure or any other context-dependent impactShow less
4Debian
FedoraprojectLibtiff+1 more
4Active Iq Unified Manager
Debian LinuxFedora+1 more
Jun 17, 2026
Mar 10, 2022
N/A· v4
6.5 MEDIUM· v3
4.3 MEDIUM· v2
Reachable Assertion in tiffcp in libtiff 4.3.0 allows attackers to cause a denial-of-service via a crafted tiff file. For users that compile libtiff from sources, the fix is available with commit 5e180045.
5Debian
FedoraprojectLinux+2 more
23Codeready Linux Builder
Debian LinuxEnterprise Linux+20 more
Jun 17, 2026
Mar 10, 2022
N/A· v4
7.8 HIGH· v3
4.6 MEDIUM· v2
A vulnerability was found in kvm_s390_guest_sida_op in the arch/s390/kvm/kvm-s390.c function in KVM for s390 in the Linux kernel. This flaw allows a local attacker with a normal user privilege to obtain unauthorized memo...Show more
A vulnerability was found in kvm_s390_guest_sida_op in the arch/s390/kvm/kvm-s390.c function in KVM for s390 in the Linux kernel. This flaw allows a local attacker with a normal user privilege to obtain unauthorized memory write access. This flaw affects Linux kernel versions prior to 5.17-rc4.Show less
3Bluez
DebianFedoraproject
3Bluez
Debian LinuxFedora
Jun 17, 2026
Mar 10, 2022
N/A· v4
8.8 HIGH· v3
5.8 MEDIUM· v2
A heap overflow vulnerability was found in bluez in versions prior to 5.63. An attacker with local network access could pass specially crafted files causing an application to halt or crash, leading to a denial of service...Show more
A heap overflow vulnerability was found in bluez in versions prior to 5.63. An attacker with local network access could pass specially crafted files causing an application to halt or crash, leading to a denial of service.Show less
2Debian
Libpano13 Project
2Debian Linux
Libpano13
Jun 17, 2026
Mar 10, 2022
N/A· v4
9.1 CRITICAL· v3
6.4 MEDIUM· v2
Panorama Tools libpano13 v2.9.20 was discovered to contain an out-of-bounds read in the function panoParserFindOLine() in parser.c.