CVEs (52)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Codesys 20Control For Beaglebone Sl Control For Beckhoff Cx9020Control For Empc A/imx6 Sl+17 moreJun 17, 2026 Apr 7, 2022 N/A· v4 6.5 MEDIUM· v3 3.5 LOW· v2 An authenticated remote attacker can cause a null pointer dereference in the CmpSettings component of the affected CODESYS products which leads to a crash. |
1Codesys 7Control Control RteControl Runtime System Toolkit+4 moreJun 17, 2026 Aug 3, 2021 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 In CODESYS V3 web server before 3.5.17.10, files or directories are accessible to External Parties. |
1Codesys 7Control Control RteControl Runtime System Toolkit+4 moreJun 17, 2026 Aug 3, 2021 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 CODESYS Control Runtime system before 3.5.17.10 has a Heap-based Buffer Overflow. |
1Codesys 22Control For Beaglebone Sl Control For Empc A/imx6 SlControl For Iot2000 Sl+19 moreJun 17, 2026 May 3, 2021 N/A· v4 7.3 HIGH· v3 7.5 HIGH· v2 CODESYS Control Runtime system before 3.5.17.0 has improper input validation. Attackers can send crafted communication packets to change the router's addressing scheme and may re-route, add, remove or change low level co...Show more |
1Codesys 11Control For Beaglebone Sl Control For Empc A/imx6 SlControl For Iot2000 Sl+8 moreJun 17, 2026 May 3, 2021 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 CODESYS Gateway 3 before 3.5.16.70 has a NULL pointer dereference that may result in a denial of service (DoS). |
1Codesys 16Control For Beaglebone Control For Empc A/imx6Control For Iot2000+13 moreJun 17, 2026 Jul 22, 2020 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 CODESYS Control runtime system before 3.5.16.10 allows Uncontrolled Memory Allocation. |
1Codesys 12Control For Beaglebone Control For Empc A/imx6Control For Iot2000+9 moreJun 17, 2026 May 14, 2020 N/A· v4 6.5 MEDIUM· v3 6.4 MEDIUM· v2 An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation. |
1Codesys 14Control For Beaglebone Control For Empc A/imx6Control For Iot2000+11 moreJun 17, 2026 Mar 26, 2020 N/A· v4 9.8 CRITICAL· v3 10.0 HIGH· v2 CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow. |
1Codesys 15Control For Beaglebone Control For Empc A/imx6Control For Iot2000+12 moreJun 17, 2026 Jan 24, 2020 N/A· v4 6.5 MEDIUM· v3 4.0 MEDIUM· v2 CODESYS Control V3, Gateway V3, and HMI V3 before 3.5.15.30 allow uncontrolled memory allocation which can result in a remote denial of service condition. |
1Codesys 14Control For Beaglebone Control For Empc A/imx6Control For Iot2000+11 moreJun 17, 2026 Nov 20, 2019 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. |
1Codesys 13Control For Beaglebone Control For Empc A/imx6Control For Iot2000+10 moreJun 17, 2026 Sep 13, 2019 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code...Show more |
1Codesys 13Control For Beaglebone Control For Empc A/imx6Control For Iot2000+10 moreJun 17, 2026 Sep 13, 2019 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. |