CVEs (8)
CVE VENDORS PRODUCTS UPDATED PUBLISHED CVSS |
|---|
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 8.8 HIGH· v3 6.5 MEDIUM· v2 In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields that are executed with root privileges. |
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 9.8 CRITICAL· v3 7.5 HIGH· v2 In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the passwor...Show more |
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 8.8 HIGH· v3 6.5 MEDIUM· v2 In Bender/ebee Charge Controllers in multiple versions are prone to Command injection via Web interface. An authenticated attacker could enter shell commands into some input fields. |
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 7.8 HIGH· v3 7.2 HIGH· v2 In Bender/ebee Charge Controllers in multiple versions are prone to Local privilege Escalation. An authenticated attacker could get root access via the suid applications socat, ip udhcpc and ifplugd. |
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 5.4 MEDIUM· v3 3.5 LOW· v2 In Bender/ebee Charge Controllers in multiple versions are prone to Cross-site Scripting. An authenticated attacker could write HTML Code into configuration values. These values are not properly escaped when displayed. |
1Bender 5Cc612 Firmware Cc613 FirmwareIcc15xx Firmware+2 moreJun 17, 2026 Apr 27, 2022 N/A· v4 7.5 HIGH· v3 5.0 MEDIUM· v2 In Bender/ebee Charge Controllers in multiple versions are prone to an RFID leak. The RFID of the last charge event can be read without authentication via the web interface. |
1Bender 2Cc612 Firmware Icc15xx FirmwareJun 17, 2026 Apr 27, 2022 N/A· v4 8.6 HIGH· v3 5.0 MEDIUM· v2 In Bender/ebee Charge Controllers in multiple versions are prone to unprotected data export. Backup export is protected via a random key. The key is set at user login. It is empty after reboot . |
2Bender Ibm5 Ibm Rational Lifecycle Integration Adapter For Windchill Cc612 FirmwareCc613 Firmware+2 moreJun 17, 2026 Apr 27, 2022 N/A· v4 5.3 MEDIUM· v3 5.0 MEDIUM· v2 In Bender/ebee Charge Controllers in multiple versions a long URL could lead to webserver crash. The URL is used as input of an sprintf to a stack variable. |