← Back
CWE-921

9 CVEs • Abstraction: Base

Storage of Sensitive Data in a Mechanism without Access Control

The product stores sensitive information in a file system or device that does not have built-in access control.

JSON object

Loading...

CVEs (9)

CVE
VENDORS
PRODUCTS
UPDATED
PUBLISHED
CVSS
-
-
Jun 17, 2026
Apr 8, 2025
N/A· v4
9.8 CRITICAL· v3
N/A· v2
SAP Financial Consolidation allows an unauthenticated attacker to gain unauthorized access to the Admin account. The vulnerability arises due to improper authentication mechanisms, due to which there is high impact on th...Show more
SAP Financial Consolidation allows an unauthenticated attacker to gain unauthorized access to the Admin account. The vulnerability arises due to improper authentication mechanisms, due to which there is high impact on the Confidentiality, Integrity & Availability of the application.Show less
-
-
Jun 17, 2026
Feb 28, 2025
5.1 MEDIUM· v4
5.1 MEDIUM· v3
N/A· v2
Insecure file retrieval process that facilitates potential for file manipulation to affect product stability and confidentiality, integrity, authenticity, and attestation of stored data.
-
-
Jun 17, 2026
Feb 27, 2025
N/A· v4
8.2 HIGH· v3
N/A· v2
Use of Hard-coded Credentials, Storage of Sensitive Data in a Mechanism without Access Control vulnerability in E-Kent Pallium Vehicle Tracking allows Authentication Bypass. This issue affects Pallium Vehicle Tracking:...Show more
Use of Hard-coded Credentials, Storage of Sensitive Data in a Mechanism without Access Control vulnerability in E-Kent Pallium Vehicle Tracking allows Authentication Bypass. This issue affects Pallium Vehicle Tracking: before 17.10.2024.Show less
-
-
Jun 17, 2026
Feb 11, 2025
N/A· v4
6.0 MEDIUM· v3
N/A· v2
SAP GUI for Windows & RFC service credentials are incorrectly stored in the memory of the program allowing an unauthenticated attacker to access information within systems, resulting in privilege escalation. On successfu...Show more
SAP GUI for Windows & RFC service credentials are incorrectly stored in the memory of the program allowing an unauthenticated attacker to access information within systems, resulting in privilege escalation. On successful exploitation, this could result in disclosure of highly sensitive information. This has no impact on integrity, and availability.Show less
1Scikit Learn
1Scikit Learn
Jun 17, 2026
Jun 6, 2024
N/A· v4
4.7 MEDIUM· v3
N/A· v2
A sensitive data leakage vulnerability was identified in scikit-learn's TfidfVectorizer, specifically in versions up to and including 1.4.1.post1, which was fixed in version 1.5.0. The vulnerability arises from the unexp...Show more
A sensitive data leakage vulnerability was identified in scikit-learn's TfidfVectorizer, specifically in versions up to and including 1.4.1.post1, which was fixed in version 1.5.0. The vulnerability arises from the unexpected storage of all tokens present in the training data within the `stop_words_` attribute, rather than only storing the subset of tokens required for the TF-IDF technique to function. This behavior leads to the potential leakage of sensitive information, as the `stop_words_` attribute could contain tokens that were meant to be discarded and not stored, such as passwords or keys. The impact of this vulnerability varies based on the nature of the data being processed by the vectorizer.Show less
-
-
Jun 17, 2026
May 3, 2024
N/A· v4
5.0 MEDIUM· v3
N/A· v2
An improper use of the SD card for sensitive data vulnerability was reported in the Motorola Device Help application that could allow a local attacker to read system logs. 
1Socomec
1Modulys Gp Firmware
Jun 17, 2026
Sep 18, 2023
N/A· v4
7.5 HIGH· v3
N/A· v2
Sending some requests in the web application of the vulnerable device allows information to be obtained due to the lack of security in the authentication process.
1Rosariosis
1Rosariosis
Jun 17, 2026
May 12, 2023
N/A· v4
7.5 HIGH· v3
N/A· v2
Storage of Sensitive Data in a Mechanism without Access Control in GitHub repository francoisjacquet/rosariosis prior to 11.0.
1Phillips
11Gemini 882160 Firmware
Gemini 882300 FirmwareGemini 882390 Firmware+8 more
Jun 17, 2026
Mar 23, 2022
N/A· v4
2.4 LOW· v3
2.1 LOW· v2
Philips Gemini PET/CT family software stores sensitive information in a removable media device that does not have built-in access control.